FIG. 3.
(a) The impact of 0.00, 0.07, 0.11, 0.17, and 0.50 mM Triton X-100 on percent hemolysis. Hemolysis decreased by 2.9% upon adding 0.07 mM Triton X-100, then increased by 4.7% as the concentration of Triton X-100 increased from 0.07 to 0.17 mM. Significance of differences was determined by calculating p-values; * represents p-values < 0.05 and ** represents p-values < 0.01. (b) Microscopy images of RBCs, mean and histogram of RBC radii at 0.00, 0.07, 0.11, and 0.17 mM Triton X-100 concentrations. RBC radii increased with Triton X-100 concentrations, which are also noted in Table I.

(a) The impact of 0.00, 0.07, 0.11, 0.17, and 0.50 mM Triton X-100 on percent hemolysis. Hemolysis decreased by 2.9% upon adding 0.07 mM Triton X-100, then increased by 4.7% as the concentration of Triton X-100 increased from 0.07 to 0.17 mM. Significance of differences was determined by calculating p-values; * represents p-values < 0.05 and ** represents p-values < 0.01. (b) Microscopy images of RBCs, mean and histogram of RBC radii at 0.00, 0.07, 0.11, and 0.17 mM Triton X-100 concentrations. RBC radii increased with Triton X-100 concentrations, which are also noted in Table I.