We have measured the retinal damage threshold for a large spot size, multiple-pulse exposure to a Q-switched, frequency-double Nd:YAG laser (532 nm, 7 ns pulses). A 500 μm diameter retinal beam spot was used. The ED50, expressed as the per-pulse energy, varies only weakly with the number of pulses, n, for this extended spot size. The previously reported threshold for a multiple-pulse exposure for a 900 μm retinal spot size also shows the same weak dependence on the number of pulses. The multiple-pulse ED50 for an extended spot-size exposure does not follow the n-1/4 dependence exhibited by small spot size exposures produced by a collimated beam.
REFERENCES
1.
American National Standard Institute (ANSI)
(2007
), American National Standard for Safe Use of Lasers
, Laser Institute of America
.2.
Stuck
, B.E.
, Lund
, D.J.
& Beatrice
, E.S.
(1978
) Repetitive Pulse Laser Data and Permissible Exposure Limits, Letterman Army Institute of Research Report No. 58
.3.
Walkenbach
, J.E.
(1972
) Determination of Retinal Lesion Threshold Energies of Pulse Repetition Nd+3:YAG Laser in the Rhesus Monkey
, Master’s Thesis, Virginia Commonwealth University
.4.
Griess
, G.A.
, Blankenstein
, M.F.
& Williford
, G.G.
(1980
) Ocular Damage from Multiple-Pulse Laser Exposures
, Health Physics
39
, 921
–927
.5.
Lund
, B.J.
(2006
) The ProbitFit Program to Analyse Data from Laser Damage Threshold Studies, Walter Reed Army Institute of Research Report No. 06/001
.6.
Menendez
, A.R.
, Cheney
, F.E.
, Zuclich
, J.A.
& Crump
, P.
(1993
) Probability-Summation Model of Multiple Laser-Exposure Effects
, Health Physics
65
, 523
–528
.
This content is only available via PDF.
© 2009 Laser Institute of America.
2009
Laser Institute of America