For the past 19 years, the Laser Hardened Materials Evaluation Laboratory, (LHMEL), located at Wright-Patterson AFB, OH, has maintained a number of calibrated high energy power measurement devices capable of measuring CO2 powers up to 150 kW. These devices, calibrated annually to the National Institute for Science & Technology’s (NIST) high energy standard calorimeters, serve as secondary standards for in-house calibration of LHMEL’s commercial power heads and calorimeters. Recent discussions with academic and industrial laser users have identified an industry need for traceable calibration sources above the 1 kW level. This paper describes the methods used to calibrate LHMEL’s commercial power measurement devices using the LHMEL secondary standards and also describes the process by which other laser users can access these same calibration capabilities to confirm the accuracy of their own power heads and calorimeters. The LHMEL calibration capability offers academic and industrial laser users the opportunity to economically calibrate existing power measurement devices on demand to an NIST-traceable secondary standard. The method described has been applied to calibrate systems up to 100 kW while maintaining measurement accuracies to within ± 6.3%.
Skip Nav Destination
ICALEO '95: Proceedings of the Laser Materials Processing Conference
November 13–16, 1995
San Diego, California, USA
ISBN:
978-0-912035-53-6
PROCEEDINGS PAPER
High power calibration of commercial power meters using an NIST-traceable secondary standard Available to Purchase
Michael L. Lander;
Michael L. Lander
1
Ogden Lawrence Associates
, Dayton, Ohio USA
Search for other works by this author on:
John O. Bagford;
John O. Bagford
1
Ogden Lawrence Associates
, Dayton, Ohio USA
Search for other works by this author on:
Daniel B. Seibert, II;
Daniel B. Seibert, II
1
Ogden Lawrence Associates
, Dayton, Ohio USA
Search for other works by this author on:
Robert J. Hull
Robert J. Hull
2
Wright Laboratory Materials Directorate Wright Patterson Air Force Base
, Ohio USA
Search for other works by this author on:
Published Online:
November 01 1995
Citation
Michael L. Lander, John O. Bagford, Daniel B. Seibert, Robert J. Hull; November 13–16, 1995. "High power calibration of commercial power meters using an NIST-traceable secondary standard." Proceedings of the ICALEO '95: Proceedings of the Laser Materials Processing Conference. ICALEO '95: Proceedings of the Laser Materials Processing Conference. San Diego, California, USA. (pp. pp. 1109-1117). ASME. https://doi.org/10.2351/1.5058892
Download citation file:
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.