Well, do you remember when a factor of 2 was good enough? Probably, not unless you have been around secondary ion mass spectrometry (SIMS) since the early 1960s, like one of us has been. This paper will give many references back to the early days of quantification when a local thermal equilibrium model was used to obtain the first results that were accurate to within a factor of 2, but only 60% of the time. It only worked for bulk silicate matrixes. People were not even using SIMS on semiconductors in those days. Several early references showing profiles of ion implants in Si will be referenced, but it was not until 1980 that the first paper was published that explicitly showed how to use ion implants as SIMS standards. People were using ion implants as standards before 1980, but only in limited cases, and with no formal published equations specifying how to use them. But, the samples for which ion implants were used as standards were for dilute concentrations in a single matrix, which had a uniform matrix composition with depth. The rest of the paper will show how we at Eurofins EAG Laboratories tackled the problem of quantification of both major and minor elements in nonuniform, multi-element matrices with continuously graded composition changes using point-by-point CORrected-SIMS. These include SiGe heterostructure bipolar transistors, AlGaAs vertical cavity surface emitting lasers, and B plasma-implanted poly-silicon gates.
Skip Nav Destination
Article navigation
Review Article|
April 20 2023
Secondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?
Special Collection:
Secondary Ion Mass Spectrometry (SIMS)
Charles W. Magee;
Charles W. Magee
a)
(Conceptualization, Writing – original draft, Writing – review & editing)
1
Eurofins EAG Laboratories
, 104 Windsor Center Drive, Suite 101, East Windsor, New Jersey 08520
Search for other works by this author on:
Temel H. Buyuklimanli
Temel H. Buyuklimanli
b)
(Conceptualization, Data curation, Software, Writing – review & editing)
2
Eurofins EAG Laboratories
, 810 Kifer Road, Sunnyvale, California 94086
Search for other works by this author on:
a)
Electronic mail:charlesmagee@eurofinseag.com
b)
Electronic mail: temel@eurofinseag.com
Note: This paper is part of the 2023 Special Topic Collection on Secondary Ion Mass Spectrometry (SIMS).
J. Vac. Sci. Technol. B 41, 030803 (2023)
Article history
Received:
December 30 2022
Accepted:
March 20 2023
Connected Content
Citation
Charles W. Magee, Temel H. Buyuklimanli; Secondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?. J. Vac. Sci. Technol. B 1 May 2023; 41 (3): 030803. https://doi.org/10.1116/6.0002466
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
Etch Pits and Polarity in CdTe Crystals
Journal of Applied Physics (June 2004)
Comparative antioxidant activity of Brucea javanica (L) Merr seed extract derived from maceration and soxhletation method
AIP Conference Proceedings (December 2019)
Prestack reverse time migration for 3D marine reflection seismic data