The use of secondary ion mass spectrometry to verify dopant profiles, either for process control or for simulation modeling, is an established practice in semiconductor fabrication, where precise dopant concentrations are integral to device performance. Of the many understood secondary ion mass spectrometry (SIMS) artifacts, the crater edge effect is one that can limit critical detection limits under conventional SIMS profiling of high dose samples. The use of a mesa structure to eliminate crater sidewall contribution is a proven remedial method, although with practical limitations associated with each iteration of the approach. This work explored a method of constructing a mesa structure using an automated dicing saw. The mesa structures were prepared relatively quickly, taking only about to construct a six mesa array per sample. Scanning electron microscopy images of cross sectioned mesa structures indicating excellent slope was achieved, without erosion of the mesa surface. Depth profiles from two examples of high dose samples were collected by both standard SIMS and mesa SIMS. Analogous mesa profiles demonstrated between 20 and 5 times gains in detection limits compared to the standard SIMS profiles, comparable to gains achieved in other mesa work. Mesa profiles appeared to be accurate, void of mesa induced artifacts, and repeatable, based on examinations of matrix intensities and peak shapes compared to the standard profiles.
Skip Nav Destination
Article navigation
March 2009
This content was originally published in
Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
Brief Report|
March 26 2009
Mesa sample preparation for secondary ion mass spectrometry depth profiling using an automated dicing saw
T. Guenther;
T. Guenther
a)
Freescale Semiconductor Inc.
, 3501 Ed Bluestein Blvd., Austin, Texas 78721
Search for other works by this author on:
Z. X. Jiang;
Z. X. Jiang
Freescale Semiconductor Inc.
, 3501 Ed Bluestein Blvd., Austin, Texas 78721
Search for other works by this author on:
K. Kim;
K. Kim
Freescale Semiconductor Inc.
, 3501 Ed Bluestein Blvd., Austin, Texas 78721
Search for other works by this author on:
D. D. Sieloff
D. D. Sieloff
Freescale Semiconductor Inc.
, 3501 Ed Bluestein Blvd., Austin, Texas 78721
Search for other works by this author on:
a)
Author to whom correspondence should be addressed; electronic mail: [email protected]
J. Vac. Sci. Technol. B 27, 677–680 (2009)
Article history
Received:
October 10 2008
Accepted:
January 12 2009
Citation
T. Guenther, Z. X. Jiang, K. Kim, D. D. Sieloff; Mesa sample preparation for secondary ion mass spectrometry depth profiling using an automated dicing saw. J. Vac. Sci. Technol. B 1 March 2009; 27 (2): 677–680. https://doi.org/10.1116/1.3079652
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Future of plasma etching for microelectronics: Challenges and opportunities
Gottlieb S. Oehrlein, Stephan M. Brandstadter, et al.
Transferable GeSn ribbon photodetectors for high-speed short-wave infrared photonic applications
Haochen Zhao, Suho Park, et al.
Suppressing oxygen vacancy formation in ZrO2 to improve electrical properties by employing MoO2 bottom electrode
Jaehyeon Yun, Seungyeon Kim, et al.
Related Content
Secondary ion mass spectrometry analysis strategy for shallow junctions on test and product silicon wafers
J. Vac. Sci. Technol. B (January 1992)
Reduction in surface roughness during secondary ion mass spectrometry depth profiling with an ion-milling method
J. Vac. Sci. Technol. B (November 2001)
Molecular beam epitaxial growth of GaAs millimeter‐wave IMPATT diode material
J. Vac. Sci. Technol. B (April 1984)
Nanometric ductile cutting characteristics of silicon wafer using single crystal diamond tools
J. Vac. Sci. Technol. B (May 2009)