The objective of this work is to develop a method for defining, a priori, a set of minimum ellipsometry measurements that provide for a near-minimal data set (measurement set) sufficient for an analysis of optically anisotropic crystals with monoclinic symmetry with minimal prior knowledge. Example measurements are obtained by reflection from two differently oriented smooth, flat, anisotropic, monoclinic β-Ga2O3 crystals. A measurement may consist of any set of common type ellipsometry data such as selected sets of normalized Jones matrix elements or selected sets of normalized Mueller matrix elements measured at selected angles of incidence and/or rotation of the sample, also know as table rotation. The only prior knowledge used here is the crystallographic surface orientation. The four complex-valued permittivity parameters of the monoclinic symmetry crystal are then the object of interest and the only remaining unknown parameters. The motif for our investigation is the desire to better understand how to reduce measurement time for the otherwise extensive data acquisition considered necessary thus far to fully characterize low-symmetry anisotropic materials in substrates and semiconductor heterostructures. The near-minimal measurement set introduced here is then obtained by selection from a prior, larger data set. The larger data set thus far largely overdetermines the amount of necessary information. The first criterion is that there be sufficient intensity of the reflected light considering the p and s polarized reflections produced by p and s polarized incident light. The second criterion for inclusion is that the permittivity tensor is sensitive to measurement, that is, a significant change in a measurement set results in a significant change in the solution for permittivity. Finally, the near-minimal measurement set must result in solvable sets of equations. This is examined by computing the Jacobian of the system of equations for various sets of measurements in order to only keep measurements for which the condition of the Jacobian falls below the threshold for usability. We find that sets containing four measurements of on-diagonal Jones matrix elements alone, obtained across a wide spread of table rotations, provide most sensitive and intrinsically sufficient information to solve for the permittivity values. In summary, the scheme consists of determining the following measurement conditions: (1) reflections of high intensity to enable accurate measurements. (2) sensitivity to the unknown parameters, and (3) a solvable set of equations.
Skip Nav Destination
Article navigation
September 2021
Research Article|
July 07 2021
Numerical ellipsometry: A method for selecting a near-minimal infrared measurement set for β-gallium oxide
Special Collection:
Gallium Oxide Materials and Devices
Frank K. Urban, III;
Frank K. Urban, III
a)
1Department of
Electrical and Computer Engineering, Florida International University
, University Park Campus, Miami, Florida 33199
Search for other works by this author on:
David Barton;
David Barton
1Department of
Electrical and Computer Engineering, Florida International University
, University Park Campus, Miami, Florida 33199
Search for other works by this author on:
Mathias Schubert
Mathias Schubert
2Department of
Electrical and Computer Engineering, University of Nebraska Lincoln
, 242N Scott Engineering Center, Lincoln, Nebraska 68588-0511
Search for other works by this author on:
a)
Electronic mail: urban@fiu.edu
Note: This paper is part of the Special Topic Collection on Gallium Oxide Materials and Devices.
J. Vac. Sci. Technol. A 39, 052801 (2021)
Article history
Received:
February 25 2021
Accepted:
June 07 2021
Citation
Frank K. Urban, David Barton, Mathias Schubert; Numerical ellipsometry: A method for selecting a near-minimal infrared measurement set for β-gallium oxide. J. Vac. Sci. Technol. A 1 September 2021; 39 (5): 052801. https://doi.org/10.1116/6.0001002
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00