A method of computation to determine the trajectories of large numbers of ions in quadrupole mass spectrometers has been developed. The computer program produces simulated mass scans with over ions injected into the quadrupole model at each point on the mass scale. The computation method has been combined with an improved representation of an ion source to predict the behavior of complete quadrupole systems; the results obtained are shown to reproduce most features of experimentally observed mass scans. The calculations show that the shape and height of mass peaks depend strongly on the properties of the ion source. However, ion source properties have a relatively small effect on the resolution of the mass spectrometer and an alternative to the common method of presenting the resolution of a quadrupole is proposed. This alternative better indicates the performance of the instrument as it is less sensitive to effects of the ion source. Results are also presented which indicate that peak splitting, closely matching experimental observations, can be produced by small changes in the exit aperture of the quadrupole.
Skip Nav Destination
Article navigation
January 2000
Research Article|
January 01 2000
Detailed simulation of mass spectra for quadrupole mass spectrometer systems
J. R. Gibson;
J. R. Gibson
Department of Electrical Engineering and Electronics, The University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
Search for other works by this author on:
S. Taylor;
S. Taylor
Department of Electrical Engineering and Electronics, The University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
Search for other works by this author on:
J. H. Leck
J. H. Leck
Department of Electrical Engineering and Electronics, The University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
Search for other works by this author on:
J. Vac. Sci. Technol. A 18, 237–243 (2000)
Article history
Received:
June 03 1999
Accepted:
September 10 1999
Citation
J. R. Gibson, S. Taylor, J. H. Leck; Detailed simulation of mass spectra for quadrupole mass spectrometer systems. J. Vac. Sci. Technol. A 1 January 2000; 18 (1): 237–243. https://doi.org/10.1116/1.582140
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
An investigation of small commercial quadrupole mass spectrometers
Journal of Vacuum Science & Technology A (July 1987)
Design and test of magnetic shields for quadrupole mass spectrometers
Journal of Vacuum Science & Technology A (February 2007)
Study of a micro chamber quadrupole mass spectrometer
Journal of Vacuum Science & Technology A (January 2008)
Effect of ion entry acceptance conditions on the performance of a quadrupole mass spectrometer operated in upper and lower stability regions
Journal of Vacuum Science & Technology A (April 2005)
Relative sensitivities of Bayard–Alpert gauges and a quadrupole mass spectrometer for hydrogen isotope molecules
Journal of Vacuum Science & Technology A (March 1987)