In this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.
Skip Nav Destination
Article navigation
March 2022
Tutorial|
April 26 2022
Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation
Special Collection:
Special Topic Collection: Tutorials in Sum-Frequency Generation Spectroscopy
Benjamin Doughty
;
Benjamin Doughty
a)
Chemical Sciences Division, Oak Ridge National Laboratory
, Oak Ridge, Tennessee 37831a)Author to whom correspondence should be addressed: doughtybl@ornl.gov
Search for other works by this author on:
Lu Lin
;
Lu Lin
Chemical Sciences Division, Oak Ridge National Laboratory
, Oak Ridge, Tennessee 37831
Search for other works by this author on:
Uvinduni I. Premadasa
;
Uvinduni I. Premadasa
Chemical Sciences Division, Oak Ridge National Laboratory
, Oak Ridge, Tennessee 37831
Search for other works by this author on:
Ying-Zhong Ma
Ying-Zhong Ma
Chemical Sciences Division, Oak Ridge National Laboratory
, Oak Ridge, Tennessee 37831
Search for other works by this author on:
a)Author to whom correspondence should be addressed: doughtybl@ornl.gov
Biointerphases 17, 021201 (2022)
Article history
Received:
February 22 2022
Accepted:
April 04 2022
Citation
Benjamin Doughty, Lu Lin, Uvinduni I. Premadasa, Ying-Zhong Ma; Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation. Biointerphases 1 March 2022; 17 (2): 021201. https://doi.org/10.1116/6.0001817
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
Citing articles via
Drug-eluting contact lenses: Progress, challenges, and prospects
Dongdong Gao, Chunxiao Yan, et al.
Influence of metal oxides on biocompatibility of additively manufactured NiTi
Maria P. Kwesiga, Roger J. Guillory, II, et al.
Related Content
High throughput wide field second harmonic imaging of giant unilamellar vesicles
Biointerphases (June 2023)