Flatness of attenuation was measured for high-fidelity hearing protection devices (HPDs) using microphone-in-real-ear (MIRE) and behavioral real-ear-attenuation-at-threshold (REAT) protocols. In addition, participants completed the words-in-noise (WIN) test with and without HPDs, and provided subjective ratings of perceived sound quality via surveys administered after listening to music with and without HPDs. Attenuation was also measured using a manikin device, with both the manikin-based microphone and the MIRE probe tube used to make measurements inside the artificial ear coupler. Among human participants, statistically significant correlations revealed decreased WIN performance and poorer music quality ratings as achieved HPD attenuation increased. There was also a statistically significant correlation in which shallower slope (flatter attenuation) was correlated with higher perceived music quality ratings. Achieved attenuation decreased in the coupler when the probe tube was inserted into the manikin, suggesting HPD seals were compromised by the probe tube. Consistent with the manikin data, attenuation in human ears was greater when measured using REAT, suggesting similar compromise of the HPD seal during MIRE tests. To assure high fidelity HPDs are well fit, REAT testing is recommended to verify both overall attenuation and flatness of attenuation in individual listeners.
Skip Nav Destination
,
Article navigation
October 2020
Meeting abstract. No PDF available.
October 01 2020
High fidelity hearing protection devices: Attenuation in human ears and manikin devices Free
Colleen Le Prell;
Colleen Le Prell
Univ. of Texas at Dallas-Callier Ctr., 1966 Inwood Rd., Callier Ctr., Rm. J216, Dallas, TX 75235, [email protected]
Search for other works by this author on:
Tess Zaccardi
Tess Zaccardi
Univ. of Texas at Dallas-Callier Ctr., Dallas, TX
Search for other works by this author on:
Colleen Le Prell
Tess Zaccardi
Univ. of Texas at Dallas-Callier Ctr., 1966 Inwood Rd., Callier Ctr., Rm. J216, Dallas, TX 75235, [email protected]
J. Acoust. Soc. Am. 148, 2779 (2020)
Citation
Colleen Le Prell, Tess Zaccardi; High fidelity hearing protection devices: Attenuation in human ears and manikin devices. J. Acoust. Soc. Am. 1 October 2020; 148 (4_Supplement): 2779. https://doi.org/10.1121/1.5147736
Download citation file:
97
Views
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
Drawer-like tunable ventilated sound barrier
Yong Ge, Yi-jun Guan, et al.
Related Content
A comparison of attenuation measurement methods of active noise reduction earmuffs
Proc. Mtgs. Acoust. (January 2023)
An objective method for measuring the attenuation of hearing protection devices using otoacoustic emissions
J. Acoust. Soc. Am. (October 2004)
Detection thresholds with active hearing protection devices in quiet and noise
J. Acoust. Soc. Am. (October 2021)
Assessment of methods for determining field‐equivalent sound levels from real‐ear and manikin measurements
J. Acoust. Soc. Am. (February 1999)
Noise reduction ratings of active noise cancellation headsets
J. Acoust. Soc. Am. (October 2016)