Rapid Doppler shifts highlight some kidney stones with a rapid change in color in ultrasound imaging which is called the “twinkling artifact.” Many hypotheses exist to describe the mechanism of twinkling, including the hypothesis that microbubbles are stabilized in crevices on the surface of kidney stones. The objective is to evaluate the distribution of stable microbubbles on kidney stone surfaces with humidity-controlled scanning electron microscopy (ESEM) and determine whether any sub-surface characteristics as assessed with micro-computed tomography (µCT) may contribute to twinkling. A Verasonics® research ultrasound system with the Verasonics L22-14 and Philips/ATL L7-4 and C5-2 transducers quantified twinkling. Results show a correlation between voids within kidney stones and the locations of twinkling on the stone surface. These voids had a calculated free-field Minneart resonant frequency of 3–9 MHz depending on the size. ESEM revealed that surfaces that twinkled had more crevices with radii corresponding to bubbles with a free-field resonant frequency of 3–7 MHz. These results suggest that internal voids and surface crevices contribute to the twinkling artifact on kidney stones.
Skip Nav Destination
Article navigation
March 2019
Meeting abstract. No PDF available.
March 01 2019
Etiology of the color Doppler twinkling artifact on kidney stones Free
Scott A. Zinck
Scott A. Zinck
Acoust., The Penn State Univ., 201E Appl. Sci. Bldg., University Park, PA 16802, [email protected]
Search for other works by this author on:
Scott A. Zinck
Acoust., The Penn State Univ., 201E Appl. Sci. Bldg., University Park, PA 16802, [email protected]
J. Acoust. Soc. Am. 145, 1922 (2019)
Citation
Scott A. Zinck; Etiology of the color Doppler twinkling artifact on kidney stones. J. Acoust. Soc. Am. 1 March 2019; 145 (3_Supplement): 1922. https://doi.org/10.1121/1.5101982
Download citation file:
68
Views
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Drawer-like tunable ventilated sound barrier
Yong Ge, Yi-jun Guan, et al.
Related Content
Etiology of the color Doppler ultrasound twinkling artifact on in situ human kidney stones
J. Acoust. Soc. Am. (October 2017)
Characterizing tissue calcifications using the color Doppler ultrasound twinkling artifact
J. Acoust. Soc. Am. (September 2018)
The link between internal microbubbles in kidney stones and the Doppler twinkling artifact
J. Acoust. Soc. Am. (October 2020)
The effect of hypobaric pressure on the kidney stone twinkling artifact
J. Acoust. Soc. Am. (March 2018)
Microbubbles on kidney stones contribute to the twinkling artifact in humans
J. Acoust. Soc. Am. (October 2019)