Quantitative high resolution (QHR) images of speed of sound and attenuation in human breast have been made using full wave inverse scattering in three-dimension (FWIS3D), where only soft tissue is present. The FWIS3D technology and method are reviewed. Recent QHR images in the presence of bone and gas have been obtained with FWIS3D and are shown. Transmission mode quantitative and refraction corrected reflection images of small piglet abdomen, thorax, and head are shown. QHR images of the human knee using the same technology are shown. Human Knee is difficult due to the predominant presence of bone. With low frequency FWIS3D, the meniscus, structure within the Femur-Tibia (F-T) space, ligaments, and the infrapatellar fat pad can be seen. The intra-condyle space in the Femur is visible. It was earlier established that 3D modelling was necessary for breast. It is shown to be even more important for F-T space and whole body imaging. Quantitative estimates of high speed early development bone are made, and imaging through neo-natal skull is performed. Clear correspondence with known structures even in the presence of gas is displayed. This reveals FWIS3D ultrasound tomography as a 21st century whole body imaging modality.
Skip Nav Destination
Article navigation
March 2019
Meeting abstract. No PDF available.
March 01 2019
Full wave 3D inverse scattering: 21st century technology for whole body imaging
James Wiskin;
James Wiskin
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
Bilal Malik;
Bilal Malik
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
Rajni Natesan;
Rajni Natesan
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
Nasser Pirshafiey;
Nasser Pirshafiey
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
Mark Lenox;
Mark Lenox
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
John Klock
John Klock
R&D, QT Ultrasound, LLC, 3 Hamilton Landing, Ste. 160, Novato, CA 94949, [email protected]
Search for other works by this author on:
J. Acoust. Soc. Am. 145, 1857 (2019)
Citation
James Wiskin, Bilal Malik, Rajni Natesan, Nasser Pirshafiey, Mark Lenox, John Klock; Full wave 3D inverse scattering: 21st century technology for whole body imaging. J. Acoust. Soc. Am. 1 March 2019; 145 (3_Supplement): 1857. https://doi.org/10.1121/1.5101706
Download citation file:
Citing articles via
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
Related Content
The influence of the industrial pig complex environment on the age characteristics of the livestock
AIP Conference Proceedings (June 2022)
DECOMPOSITION OF INTERFERING ULTRASONIC WAVES IN BONE AND BONE‐MIMICKING MATERIALS
AIP Conference Proceedings (December 2009)
Successful use of Bayesian inference to obtain the fast and slow wave properties of cancellous bone from sonometry measurements.
J Acoust Soc Am (April 2009)
Inverse problems in cancellous bone: Estimation of the ultrasonic properties of fast and slow waves using Bayesian probability theory
J. Acoust. Soc. Am. (November 2010)
The soundscape of Sen. Salgado Filho Avenue, Natal/RNBrazil: The acoustic impact caused by the insertion of semi-exclusive bus lane
J. Acoust. Soc. Am. (October 2019)