Quantitative measurement of flow in blood vessels is important to assess cardiovascular dynamics. The objective of the present study is to obtain two-dimensional (2D) blood flow vector in some carotid artery models and to validate the method in comparison with particle image velocimetry (PIV). Plane wave ultrasound with the repetition rate of 14 kHz was transmitted and received by a 7.5 MHz linear array transducer and a programmable ultrasound data acquisition system. Compound B-mode images and dual-angle Doppler data with the transmission angle of -10° and + 10° were obtained. 2D flow vector at arbitrary point was calculated by two velocity components along with each angle. Steady and pulsatile flow in normal and stenosed carotid artery models were simultaneously observed by the proposed method and PIV. 2D velocity vectors were successfully obtained in each flow states and the average error was approximately 5% in comparison with PIV in the carotid artery model. Steady flow in the distal stenosis model showed that the blood flow was influenced by vascular resistance while pulsatile flow seemed to push the blood to the high resistance portion. 2D blood flow obtained with dual-angle Doppler signal may provide important information in understanding cardiovascular dynamics.
Skip Nav Destination
,
,
,
,
,
Article navigation
October 2016
Meeting abstract. No PDF available.
October 01 2016
Two-dimensional blood flow vector obtained with high frame rate acquisition of dual-angle Doppler signal Free
Yoshifumi Saijo;
Yoshifumi Saijo
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Osamu Akagawa;
Osamu Akagawa
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Kosuke Fukazu;
Kosuke Fukazu
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Naoya Tsugita;
Naoya Tsugita
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Sou Yaegashi;
Sou Yaegashi
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Ryo Nagaoka
Ryo Nagaoka
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
Search for other works by this author on:
Yoshifumi Saijo
Osamu Akagawa
Kosuke Fukazu
Naoya Tsugita
Sou Yaegashi
Ryo Nagaoka
Tohoku Univ., 4-1 Seiryomachi, Aoba-ku, Sendai 980-8575, Japan, [email protected]
J. Acoust. Soc. Am. 140, 3027–3028 (2016)
Citation
Yoshifumi Saijo, Osamu Akagawa, Kosuke Fukazu, Naoya Tsugita, Sou Yaegashi, Ryo Nagaoka; Two-dimensional blood flow vector obtained with high frame rate acquisition of dual-angle Doppler signal. J. Acoust. Soc. Am. 1 October 2016; 140 (4_Supplement): 3027–3028. https://doi.org/10.1121/1.4969392
Download citation file:
61
Views
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
Related Content
Non-Kolmogorov turbulence in carotid artery stenosis and the impact of carotid stenting on near-wall turbulence
AIP Advances (January 2022)
Computational hemodynamics and hemoacoustic study on carotid bifurcation: Effect of stenosis and branch angle
Physics of Fluids (April 2024)
Hemodynamic assessment of severely stenotic carotid arteries
Physics of Fluids (May 2024)