Dental implants are widely used for oral rehabilitation. However, there remain risks of failure that are difficult to anticipate. The objective of this study is to investigate the potentiality of quantitative ultrasound (QUS) to assess dental implant implant stability. To do so, the implant is initially completely inserted in the proximal part of a bovine humeral bone sample. The 10 MHz ultrasonic response of the implant is then measured and a quantitative indicator I is derived based on the rf signal obtained. Then, the implant is unscrewed by 2π radians and the measurement is realized again. The procedure is repeated seven times and the indicator is derived after each rotation of the implant. Analysis of variance (ANOVA) (p < 10−5) tests revealed a significant effect of the amount of bone in contact with the implant on the distribution of I. In parallel, a finite element model is developed in order to model the ultrasonic propagation in the implant surrounded by bone tissue. The results show the feasibility of our QUS device to assess implant primary stability. A good agreement is obtained between experimental and numerical results. This study paves the way for the development of a new approach in oral implantology.
Skip Nav Destination
Article navigation
September 2015
Meeting abstract. No PDF available.
September 01 2015
Assessing dental implant stability using quantitative ultrasound methods: Experimental approach and numerical validation Free
Romain Vayron;
Romain Vayron
Multiscale Modeling and Simulation Lab., CNRS, Laboratoire MSMS, Faculté des Sci., UPEC, 61 Ave. du gal de Gaulle, Creteil 94010, France, [email protected]
Search for other works by this author on:
Guillaume Haiat
Guillaume Haiat
Multiscale Modeling and Simulation Lab., CNRS, Laboratoire MSMS, Faculté des Sci., UPEC, 61 Ave. du gal de Gaulle, Creteil 94010, France, [email protected]
Search for other works by this author on:
Romain Vayron
Multiscale Modeling and Simulation Lab., CNRS, Laboratoire MSMS, Faculté des Sci., UPEC, 61 Ave. du gal de Gaulle, Creteil 94010, France, [email protected]
Guillaume Haiat
Multiscale Modeling and Simulation Lab., CNRS, Laboratoire MSMS, Faculté des Sci., UPEC, 61 Ave. du gal de Gaulle, Creteil 94010, France, [email protected]
J. Acoust. Soc. Am. 138, 1799 (2015)
Citation
Romain Vayron, Guillaume Haiat; Assessing dental implant stability using quantitative ultrasound methods: Experimental approach and numerical validation. J. Acoust. Soc. Am. 1 September 2015; 138 (3_Supplement): 1799. https://doi.org/10.1121/1.4933709
Download citation file:
66
Views
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
Related Content
A quantitative ultrasound method to estimate dental implant stability
J. Acoust. Soc. Am. (May 2017)
Ultrasonic assessment of the in vitro biomechanical stability of a dental implant
Proc. Mtgs. Acoust. (May 2013)
Ultrasonic assessment of the in vitro biomechanical stability of a dental implant
J. Acoust. Soc. Am. (May 2013)
Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study
J. Acoust. Soc. Am. (February 2016)
Reflection of an ultrasonic wave on the bone-implant interface: Comparison of two-dimensional and three-dimensional numerical models
J. Acoust. Soc. Am. (January 2020)