Ideally, respiratory masks, when used to make certain measurements of speech and singing, should not interfere with what is being measured. Unfortunately this is not always the case. In this paper, two masks intended for speech measurements, are experimentally compared. One is a hard-walled mask manufactured and marketed by Kay-Pentax. The other is the circumferentially-vented pneumotachograph (CV) mask manufactured and marketed by Glottal (Syracuse, NY). Distortion measures, as quantified by formant frequencies, and muffling measures, as quantified by estimated mask transfer functions, indicate that the hard-walled mask interferes with the speech characteristics much more than does the CV mask. It is hypothesized that SPL measurements are also likely to be inaccurate if taken when using the hard-walled mask.
Skip Nav Destination
Article navigation
April 2015
Article Contents
Meeting abstract. No PDF available.
April 01 2015
On the use of respiratory masks for speech measurements Free
Hao Zhang;
Hao Zhang
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
Search for other works by this author on:
Xiao Chen;
Xiao Chen
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
Search for other works by this author on:
Stephen Zahorian
Stephen Zahorian
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
Search for other works by this author on:
Hao Zhang
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
Xiao Chen
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
Stephen Zahorian
Dept. of Elec. and Comput. Eng., State Univ. of New York at Binghamton, Binghamton University, Binghamton, NY 13902, [email protected]
J. Acoust. Soc. Am. 137, 2302–2303 (2015)
Citation
Hao Zhang, Xiao Chen, Stephen Zahorian; On the use of respiratory masks for speech measurements. J. Acoust. Soc. Am. 1 April 2015; 137 (4_Supplement): 2302–2303. https://doi.org/10.1121/1.4920406
Download citation file:
84
Views
Citing articles via
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
Effects of network selection and acoustic environment on bounding-box object detection of delphinid whistles using a deep learning tool
Peter C. Sugarman, Elizabeth L. Ferguson, et al.
Introduction to the special issue on: Advances in soundscape: Emerging trends and challenges in research and practice
Francesco Aletta, Bhan Lam, et al.
Related Content
Video‐tape presentation of aerodynamic and respiratory kinematic measures during speech
J. Acoust. Soc. Am. (April 1993)
Respiratory volume expenditures in the speech of the hearing impaired
J. Acoust. Soc. Am. (August 2005)
Simultaneous measurement of respiratory and laryngeal function during comfortable, soft, and loud speech
J. Acoust. Soc. Am. (August 2005)
Effects of oral structures on airway conductance during normal speech
J. Acoust. Soc. Am. (August 2005)
Induced transglottal pressure variations during voicing
J. Acoust. Soc. Am. (August 2005)