There is a growing demand to perform focal surgery, particularly for prostate and kidney tumors. RF and Cryo ablation are used for treatment of tumors; however, there are reported complications mainly skipping of cancer cells and bleeding. It has been shown that HIFU can provide acoustic hemostasis to overcome such complications. However, HIFU must compete with these modalities with improved treatment efficiency and the size of the applicator must fit in a 12 mm trocar/port used during the laparoscopic surgery. We modified the Sonatherm-600i applicator and transducer that generates a split beam HIFU at 4 MHz with a center element for imaging operating at 6.5 MHz. The transducer is integrated in a robotic probe that renders bi-plane images for tissue localization and ablation. Based on selected tissue ablation volume, treatment trajectory is generated by the computer to provide optimum thermal dose to result in complete coagulative necrosis. The treatment is conducted using continuous HIFU with an interlaced imaging for tissue change monitoring. The ablation efficiency of this device is @ 1 cc/min that is better than Cryo and RF ablation. Results will be presented from recent animal studies.
Skip Nav Destination
,
Article navigation
November 2013
Meeting abstract. No PDF available.
November 01 2013
Laparoscopic high intensity focused ultrasound for the treatment of soft tissue
Narendra T. Sanghvi;
Narendra T. Sanghvi
R & D, SonaCare Medical, 4000 Pendleton Way, Indianapolis, IN 46226, [email protected]
Search for other works by this author on:
Adam Morris
Adam Morris
R & D, SonaCare Medical, 4000 Pendleton Way, Indianapolis, IN 46226, [email protected]
Search for other works by this author on:
Narendra T. Sanghvi
Adam Morris
R & D, SonaCare Medical, 4000 Pendleton Way, Indianapolis, IN 46226, [email protected]
J. Acoust. Soc. Am. 134, 4180 (2013)
Citation
Narendra T. Sanghvi, Adam Morris; Laparoscopic high intensity focused ultrasound for the treatment of soft tissue. J. Acoust. Soc. Am. 1 November 2013; 134 (5_Supplement): 4180. https://doi.org/10.1121/1.4831324
Download citation file:
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
Related Content
High intensity focused ultrasound laparoscopic instrument for partial nephrectomy
J. Acoust. Soc. Am. (November 2013)
The Laparosound{trade mark, serif}-an ultrasonic morcellator for use in laparoscopic surgery
AIP Conf. Proc. (May 2012)
Laparoscopic partial kidney ablation using high‐intensity focused ultrasound
J. Acoust. Soc. Am. (May 2001)
Image guided acoustic hemostasis
J. Acoust. Soc. Am. (April 2005)
High intensity focused ultrasound for arrest of bleeding
J. Acoust. Soc. Am. (November 2001)