Previous studies have demonstrated that blood echogenicity is highly variable depending on blood flow velocity and pulsatility mainly due to the variation of red blood cell (RBC) aggregation. However, most of the studies were performed in a mock-flow loop using porcine blood and the results were not fully validated in vivo. Rat was rarely used for investigation of RBC aggregation due to its low aggregation tendency. But high-frequency ultrasound may detect the RBC aggregation from rat blood. The purpose of the present study is to investigate the cyclic and radial variation of blood echogenicty in rat arteries using a high-frequency ultrasound system with a 40-MHz scanner. B-mode images of blood were acquired from various arteries, including carotid artery and abdominal aorta. Blood echogenicity increased at systole and decreased at diastole. The cyclic variation was larger at the vessel center than near the vessel wall. The central hypoechoic zone ('black hole' phenomenon) was observed in carotid arteries. The experimental results from rat arteries in vivo corroborate the previous observations of cyclic and radial variations of blood echogenicity from porcine blood in mock-flow loops. Acknowledgments: This work was supported by the Korea Research Foundation Grant funded by the Korean Government (NRF-2011-0017984).
Skip Nav Destination
Article navigation
April 2012
Meeting abstract. No PDF available.
April 01 2012
Observation of blood echogenicity variation in rat arteries using high-frequency ultrasound
Kweon-Ho Nam;
Kweon-Ho Nam
Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Namgu, Pohang 790-784, Korea, [email protected]
Search for other works by this author on:
Eunseop Yeom;
Eunseop Yeom
Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Namgu, Pohang 790-784, Korea, [email protected]
Search for other works by this author on:
Sang Joon Lee;
Sang Joon Lee
Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Namgu, Pohang 790-784, Korea, [email protected]
Search for other works by this author on:
Dong-Guk Paeng
Dong-Guk Paeng
Department of Ocean System Engineering, Jeju National University, Ara 1-dong, 102 Jejudaehakno, Jeju 690-756, Korea
Search for other works by this author on:
J. Acoust. Soc. Am. 131, 3363 (2012)
Citation
Kweon-Ho Nam, Eunseop Yeom, Sang Joon Lee, Dong-Guk Paeng; Observation of blood echogenicity variation in rat arteries using high-frequency ultrasound. J. Acoust. Soc. Am. 1 April 2012; 131 (4_Supplement): 3363. https://doi.org/10.1121/1.4708674
Download citation file:
65
Views
Citing articles via
All we know about anechoic chambers
Michael Vorländer
Day-to-day loudness assessments of indoor soundscapes: Exploring the impact of loudness indicators, person, and situation
Siegbert Versümer, Jochen Steffens, et al.
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Related Content
Smoking effects on cyclic variation of harmonic echogenicity in carotid artery.
J Acoust Soc Am (April 2011)
Cyclic and radial variation of the echogenicity from human carotid artery and porcine blood
J Acoust Soc Am (May 2002)
A preliminary study of ultrasound blood imaging in the common carotid artery of stroke patients
J Acoust Soc Am (April 2012)
Contrast‐enhanced detection of arterial bleeding
J Acoust Soc Am (April 2005)
Correlation between the pulse wave and the blood echogenicity in the radial artery.
J Acoust Soc Am (April 2011)