A pulsatile flow phantom has been developed for controlled studies of acoustic hemostasis and high intensity focused ultrasound (HIFU) effects on blood vessels. The flow phantom consists of an excised carotid artery attached to a pulsatile pump and embedded in an optically and acoustically transparent gel to create an ex vivo model of a human artery. The artery was punctured with a needle to simulate percutaneous vascular injury. A HIFU transducer with a focal distance of 6 cm and a frequency of 3.33 MHz was used to treat the puncture. B‐mode and power‐Doppler ultrasound were used to locate the site of the puncture, target the HIFU focus, and monitor treatment. Also, the effects of vascular flow on HIFU lesions were studied by treating vessels in the phantom for different times at a variety of flows. In both studies, histology was done on the artery. In nine trials, HIFU was able to provide complete hemostasis in 55 ± 31 s. It is feasible to use the flow phantom to study acoustic hemostasis of blood vessels. Histology shows that the flow in the phantom appears to diminish the vascular damage from HIFU.
Skip Nav Destination
,
Article navigation
April 2005
Meeting abstract. No PDF available.
April 01 2005
A pulsatile flow phantom for image‐guided high‐intensity focused ultrasound studies on blood vessels
Robyn Greaby;
Robyn Greaby
Ctr. for Medical and Industrial Ultrasound, APL, Univ. of Washington, 1013 NE 40th St., Seattle, WA 98105‐6698
Search for other works by this author on:
Shahram Vaezy
Shahram Vaezy
Ctr. for Medical and Industrial Ultrasound, APL, Univ. of Washington, 1013 NE 40th St., Seattle, WA 98105‐6698
Search for other works by this author on:
Robyn Greaby
Shahram Vaezy
Ctr. for Medical and Industrial Ultrasound, APL, Univ. of Washington, 1013 NE 40th St., Seattle, WA 98105‐6698
J. Acoust. Soc. Am. 117, 2584 (2005)
Citation
Robyn Greaby, Shahram Vaezy; A pulsatile flow phantom for image‐guided high‐intensity focused ultrasound studies on blood vessels. J. Acoust. Soc. Am. 1 April 2005; 117 (4_Supplement): 2584. https://doi.org/10.1121/1.4777090
Download citation file:
64
Views
Citing articles via
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
Related Content
A Pulsatile Flow Phantom for Image‐Guided HIFU Hemostasis of Blood Vessels
AIP Conf. Proc. (March 2005)
High intensity focused ultrasound characterization of deep bleeder acoustic coagulation cuffs.
J. Acoust. Soc. Am. (April 2011)
Contrast‐enhanced detection of arterial bleeding
J. Acoust. Soc. Am. (April 2005)
Intra‐operative Hemostasis of Punctured Femoral Artery Using HIFU: A Survival Study
AIP Conf. Proc. (March 2005)
Initial platelet aggregation in the complex shear environment of a punctured vessel model
Physics of Fluids (July 2023)