In thoracic surgery, bleeding and air leaks from the lungs can be difficult to control. We have investigated the use of high intensity focused ultrasound (HIFU) for control of lung bleeding and air leaks in operative situations. An intraoperative HIFU device, equipped with a Titanium coupler, was used. The HIFU transducer was a PZT‐8 concave element, with a focal length of 5 cm, and a diameter of 2.5 cm. The transducer was operated at 5.7 MHz and intensity of 5000 W/cm2. The coupler length was 4 cm, placing the focal volume, defined by full‐width half‐maximum at approximately 1 cm from the tip of the coupler. A pig animal model was used. Incisions in the lung were made, having lengths of 2–5 cm, and depths of 3–10 mm which created both parenchymal hemorrhage and air leakage from the lung. HIFU was applied within 10 seconds of inducing the injury. The average hemostasis time was approximately 60 seconds. All incisions were completely sealed, and no blood or air leaked from the incisions. Intraoperative HIFU may provide an effective method in various pulmonary surgery indications, and hemostasis and control of air leaks from lacerations due to trauma. [Work supported by NIH and NSF.]
Skip Nav Destination
,
,
,
,
,
,
Article navigation
November 2002
Meeting abstract. No PDF available.
October 25 2002
High intensity focused ultrasound for treatment of bleeding and air leaks due to lung trauma Free
Shahram Vaezy;
Shahram Vaezy
Appl. Phys. Lab., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Roy Martin;
Roy Martin
Appl. Phys. Lab., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Larry Crum;
Larry Crum
Appl. Phys. Lab., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Carol Cornejo;
Carol Cornejo
Harborview Medical Ctr., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Jerry Jurkovich;
Jerry Jurkovich
Harborview Medical Ctr., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Sam Sharar;
Sam Sharar
Harborview Medical Ctr., Univ. of Washington, Seattle, WA 98195
Search for other works by this author on:
Savvas Nicolaou
Savvas Nicolaou
Univ. of British Columbia
Search for other works by this author on:
Shahram Vaezy
Roy Martin
Larry Crum
Carol Cornejo
Jerry Jurkovich
Sam Sharar
Savvas Nicolaou
Appl. Phys. Lab., Univ. of Washington, Seattle, WA 98195
J. Acoust. Soc. Am. 112, 2369 (2002)
Citation
Shahram Vaezy, Roy Martin, Larry Crum, Carol Cornejo, Jerry Jurkovich, Sam Sharar, Savvas Nicolaou; High intensity focused ultrasound for treatment of bleeding and air leaks due to lung trauma. J. Acoust. Soc. Am. 1 November 2002; 112 (5_Supplement): 2369. https://doi.org/10.1121/1.4779612
Download citation file:
61
Views
Citing articles via
Focality of sound source placement by higher (ninth) order ambisonics and perceptual effects of spectral reproduction errors
Nima Zargarnezhad, Bruno Mesquita, et al.
A survey of sound source localization with deep learning methods
Pierre-Amaury Grumiaux, Srđan Kitić, et al.
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
Related Content
The use of homemade microbubbles in detection of organ bleeding and enhancement of high‐intensity focused ultrasound therapy
J. Acoust. Soc. Am. (November 2006)
Acoustic hemostasis
J. Acoust. Soc. Am. (October 1999)
Acoustic hemostasis
AIP Conf. Proc. (July 2000)
High intensity focused ultrasound for arrest of bleeding
J. Acoust. Soc. Am. (November 2001)
Image guided acoustic hemostasis
J. Acoust. Soc. Am. (April 2005)