Hearing aids are commonly fit with ear canals partially or fully open—a condition that increases the risk of acoustic feedback. Feedback limits the audiometric fitting range of devices by limiting usable gain. To guide clinical decision making and device selection, we developed the Peak Height Insertion Gain (PHIG) method to detect feedback spikes in the short-term insertion gain derived from audio recordings. Using a manikin, 145 audio recordings of a speech signal were obtained from seven hearing aids. Each hearing aid was programmed for a moderate high-frequency hearing loss with systematic variations in frequency response, gain, and feedback suppression; this created audio recordings that varied the presence and strength of feedback. Using subjective ratings from 13 expert judges, the presence of feedback was determined and then classified according to its temporal and tonal qualities. These classifications were used to optimize parameters for two versions of the PHIG method based on global and local analyses. When specificity was fixed at 0.95, the sensitivity of the global analysis was 0.86 and increased to 0.95 when combined with the local analysis. Without compromising performance, a clinically expedient version of the PHIG method can be obtained using only a single measurement.
Skip Nav Destination
Article navigation
September 2021
September 07 2021
The peak height insertion gain (PHIG) method for quantifying acoustic feedback in hearing aids
Joshua M. Alexander;
Joshua M. Alexander
a)
1
Department of Speech, Language, and Hearing Sciences, Purdue University
, West Lafayette, Indiana 47907, USA
Search for other works by this author on:
Stephanie Schmig;
Stephanie Schmig
1
Department of Speech, Language, and Hearing Sciences, Purdue University
, West Lafayette, Indiana 47907, USA
Search for other works by this author on:
Randall P. Wagner;
Randall P. Wagner
2
Physical Measurement Laboratory, National Institute of Standards and Technology
, Gaithersburg, Maryland 20899, USA
Search for other works by this author on:
Steve Armstrong
Steve Armstrong
3
SoundsGood Labs
, Burlington, Ontario, Canada
Search for other works by this author on:
a)
Electronic mail: alexan14@Purdue.edu, ORCID: 0000-0002-4292-7109.
J. Acoust. Soc. Am. 150, 1635–1651 (2021)
Article history
Received:
January 22 2021
Accepted:
August 05 2021
Citation
Joshua M. Alexander, Stephanie Schmig, Randall P. Wagner, Steve Armstrong; The peak height insertion gain (PHIG) method for quantifying acoustic feedback in hearing aids. J. Acoust. Soc. Am. 1 September 2021; 150 (3): 1635–1651. https://doi.org/10.1121/10.0005987
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
175
Views