In this paper, an extracorporeal shock wave source composed of small ellipsoidal sparker units is described. The sparker units were arranged in an array designed to produce a coherent shock wave of sufficient strength to fracture kidney stones. The objective of this paper was to measure the acoustical output of this array of 18 individual sparker units and compare this array to commercial lithotripters. Representative waveforms acquired with a fiber-optic probe hydrophone at the geometric focus of the sparker array indicated that the sparker array produces a shock wave (P+ ∼40–47 MPa, P ∼2.5–5.0 MPa) similar to shock waves produced by a Dornier HM-3 or Dornier Compact S. The sparker array's pressure field map also appeared similar to the measurements from a HM-3 and Compact S. Compared to the HM-3, the electrohydraulic technology of the sparker array produced a more consistent SW pulse (shot-to-shot positive pressure value standard deviation of ±4.7 MPa vs ±3.3 MPa).

1.
C.
Chaussy
,
E.
Schmiedt
,
D.
Jocham
,
W.
Brendel
,
B.
Forssmann
, and
V.
Walther
, “
First clinical experience with extracorporeally induced destruction of kidney stones by shock waves
,”
J. Urol.
127
,
417
420
(
1982
).
2.
J. J.
Rassweiler
,
T.
Knoll
,
K.-U.
Köhrmann
,
J. A.
McAteer
,
J. E.
Lingeman
,
R. O.
Cleveland
,
M. R.
Bailey
, and
C.
Chaussy
, “
Shock wave technology and application: An update
,”
Eur. Urol.
59
,
784
796
(
2011
).
3.
J. J.
Rassweiler
,
G. G.
Tailly
, and
C.
Chaussy
, “
Progress in lithotripter technology
,”
EAU Update Ser.
3
,
17
39
(
2005
).
4.
V. A.
Leitao
,
W. N.
Simmons
,
Y.
Zhou
,
J.
Qin
,
F. H.
Cocks
,
J.
Fehre
,
B.
Granz
,
R.
Nanke
,
G. M.
Preminger
, and
P.
Zhong
, “
In vitro comparison between HM-3 and Modularis lithotripters
,”
AIP Conf. Proc.
900
,
372
376
(
2006
).
5.
J. E.
Lingeman
, “
Lithotripsy systems
,” in
Smith's Textbook of Endourology
, 2nd ed., edited by
A. D.
Smith
,
G.
Badlani
,
D.
Bagley
,
R. V.
Clayman
,
S. G.
Docimo
,
G. H.
Jordan
,
L. R.
Kavoussi
,
B. R.
Lee
,
J. E.
Lingeman
,
G. M.
Preminger
, and
J. W.
Segura
(
BC Decker Inc
,
Hamilton
,
2007
), Chap. 39, pp.
333
342
.
6.
I.
Manousakas
,
S.-M.
Liang
,
L.-R.
Wan
, and
C.-H.
Wang
, “
Development of a system of automatic gap-adjusted electrodes for shock wave generators
,”
Rev. Sci. Instrum.
75
(
11
),
4811
4819
(
2004
).
7.
Y. A.
Pishchalnikov
,
J. A.
McAteer
,
J. C.
Williams
,
B. A.
Connors
,
R. K.
Handa
,
J. A.
Lingeman
, and
A. P.
Evan
, “
Evaluation of the LitoGold LG-380 lithotripter: In vitro acoustic characterization and assessment of renal injury in the pig model
,”
J. Endourol.
27
(5),
631
639
(
2013
).
8.
D.
Cathignol
,
J.
Mestas
,
F.
Gomez
, and
P.
Lenz
, “
Influence of water conductivity on the efficiency and the reproducibility of electrohydraulic shock wave generation
,”
Ultrasound Med. Biol.
17
,
819
828
(
1991
).
9.
M.
Bourlion
,
P.
Dancer
,
F.
Lacoste
,
J. L.
Mestas
, and
D.
Cathignol
, “
Design and characterization of a shock wave generator using canalized electrical discharge: Application to lithotripsy
,”
Rev. Sci. Instrum.
65
(
7
),
2356
2363
(
1994
).
10.
Y. A.
Pishchalnikov
,
J. S.
Neucks
,
R. J.
VonDerHaar
,
I. V.
Pishchalnikova
,
J. C.
Williams
, and
J. A.
McAteer
, “
Air pockets trapped during routine coupling in dry head lithotripsy can significantly decrease the delivery of shock wave energy
,”
J. Urol.
176
,
2706
2710
(
2006
).
11.
J. S.
Neucks
,
Y. A.
Pishchalnikov
,
A. J.
Zancanaro
,
J. N.
VonDerHaar
,
J. C.
Williams
, and
J. A.
McAteer
, “
Improved acoustic coupling for shock wave lithotripsy
,”
Urol. Res.
36
,
61
66
(
2008
).
12.
G.
Li
,
J. C.
Williams
,
Y. A.
Pishchalnikov
,
Z.
Liu
, and
J. A.
McAteer
, “
Size and location of defects at the coupling interface affect lithotripter performance
,”
BJU Int.
110
,
E871
877
(
2012
).
13.
Y. A.
Pishchalnikov
,
J. A.
McAteer
,
R. J.
VonDerHaar
,
I. V.
Pishchalnikova
,
J. C.
Williams
, and
A. P.
Evan
, “
Detection of significant variation in acoustic output of an electromagnetic lithotriptor
,”
J. Urol.
176
,
2294
2298
(
2006
).
14.
Y. A.
Pishchalnikov
,
J. A.
McAteer
, and
J. C.
Williams
, “
Effect of firing rate on the performance of shock wave lithotriptors
,”
BJU Int.
102
,
1681
1686
(
2008
).
15.
M. A.
Averkiou
and
R. O.
Cleveland
, “
Modeling of an electrohydraulic lithotripter with the KZK equation
,”
J. Acoust. Soc. Am.
106
,
102
112
(
1999
).
16.
R. O.
Cleveland
,
M. R.
Bailey
,
N.
Fineberg
,
B.
Hartenbaum
,
M.
Lokhandwalla
,
J. A.
McAteer
, and
B.
Sturtevant
, “
Design and characterization of a research electrohydraulic lithotripter patterned after the Dornier HM3
,”
Rev. Sci. Instrum.
71
,
2514
2525
(
2000
).
17.
D. L.
Sokolov
,
M. R.
Bailey
,
L. A.
Crum
,
P. M.
Blomgren
,
B. A.
Connors
, and
A. P.
Evan
, “
Prefocal alignment improves stone comminution in shockwave lithotripsy
,”
J. Endourol.
16
,
709
715
(
2002
).
18.
M. R.
Bailey
,
D. T.
Blackstock
,
R. O.
Cleveland
, and
L. A.
Crum
, “
Comparison of electrohydraulic lithotripters with regid and pressure-release ellipsoidal reflectors. I. Acoustic fields
,”
J. Acoust. Soc. Am.
104
,
2517
2523
(
1998
).
19.
W.
Eisenmenger
,
X.
Du
,
C.
Tang
,
S.
Zhao
,
Y.
Wang
,
F.
Rong
,
D.
Dai
,
M.
Guan
, and
A.
Qi
, “
The first clinical results of wide-focus and low-pressure ESWL
,”
Ultrasound Med. Biol.
28
,
769
774
(
2002
).
20.
W.
Eisenmenger
, “
The mechanisms of stone fragmentation in ESWL
,”
Ultrasound Med. Biol.
27
,
683
693
(
2001
).
21.
O. A.
Sapozhnikov
,
A. D.
Maxwell
,
B.
MacConaghy
, and
M. R.
Bailey
, “
A mechanistic analysis of stone fracture in lithotripsy
,”
J. Acoust. Soc. Am.
121
,
1190
1202
(
2007
).
22.
R. O.
Cleveland
,
R.
Anglade
, and
R. K.
Babayan
, “
Effect of stone motion on in vitro comminution efficiency of Storz Modulith SLX
,”
J. Endourol.
18
,
629
633
(
2004
).
23.
M. D.
Sorensen
,
M. R.
Bailey
,
A. R.
Shah
,
R. S.
Hsi
,
M.
Paun
, and
J. D.
Harper
, “
Quantitative assessment of shockwave lithotripsy accuracy and the effect of respiratory motion
,”
J. Endourol.
26
,
1070
1074
(
2012
).
24.
J. E.
Lingeman
,
J. A.
McAteer
,
E.
Gnessin
, and
A. P.
Evan
, “
Shock wave lithotripsy: Advances in technology and technique
,”
Nat. Rev. Urol.
6
,
660
670
(
2009
).
25.
D. L.
Sokolov
,
M. R.
Bailey
, and
L. A.
Crum
, “
Dual-pulse lithotripter accelerates stone fragmentation and reduces cell lysis in vitro
,”
Ultrasound Med. Biol.
29
,
1045
1052
(
2003
).
You do not currently have access to this content.