Sonoelastography is an ultrasonic technique that uses Kasai's autocorrelation algorithms to generate qualitative images of tissue elasticity using external mechanical vibrations. In the absence of synchronization between the mechanical vibration device and the ultrasound system, the random initial phase and finite ensemble length of the data packets result in temporal artifacts in the sonoelastography frames and, consequently, in degraded image quality. In this work, the analytic derivation of an optimal selection of acquisition parameters (i.e., pulse repetition frequency, vibration frequency, and ensemble length) is developed in order to minimize these artifacts, thereby eliminating the need for complex device synchronization. The proposed rule was verified through experiments with heterogeneous phantoms, where the use of optimally selected parameters increased the average contrast-to-noise ratio (CNR) by more than 200% and reduced the CNR standard deviation by 400% when compared to the use of arbitrarily selected imaging parameters. Therefore, the results suggest that the rule for specific selection of acquisition parameters becomes an important tool for producing high quality sonoelastography images.

1.
S.
Huang
,
R. M.
Lerner
, and
K. J.
Parker
, “
On estimating the amplitude of harmonic vibration from the Doppler spectrum of reflected signals
,”
J. Acoust. Soc. Am.
88
,
2702
2712
(
1990
).
2.
C.
Kasai
,
K.
Namekawa
,
A.
Koyano
, and
R.
Omoto
, “
Real-time two-dimensional blood flow imaging using an autocorrelation technique
,”
IEEE Trans. Sonics Ultrasonics
32
,
458
464
(
1985
).
3.
A.
Chan
,
E.
Lam
, and
V.
Srinivasan
, “
Comparison of Kasai autocorrelation and maximum likelihood estimators for Doppler optical coherence tomography
,”
IEEE Trans. Med. Imag.
32
,
1033
1042
(
2013
).
4.
S.
Huang
,
R. M.
Lerner
, and
K. J.
Parker
, “
Time domain Doppler estimators of the amplitude of vibrating targets
,”
J. Acoust. Soc. Am.
91
,
965
974
(
1992
).
5.
G.
Torres
,
J.
Ormachea
,
R. J.
Lavarello
,
K. J.
Parker
, and
B.
Castaneda
, “
Effects of data acquisition parameters on the quality of sonoelastographic imaging
,” in
37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
,
2015
, pp.
3839
3842
.
6.
Z.
Hah
,
C.
Hazard
,
B.
Mills
,
C.
Barry
,
D.
Rubens
, and
K.
Parker
, “
Integration of crawling waves in an ultrasound imaging system. Part 2: Signal processing and applications
,”
Ultrasound Med. Biol.
38
,
312
323
(
2012
).
You do not currently have access to this content.