Hearing aid equivalent input noise (EIN) measures assume the primary source of internal noise to be located prior to amplification and to be constant regardless of input level. EIN will underestimate internal noise in the case that noise is generated following amplification. The present study investigated the internal noise levels of six hearing aids (HAs). Concurrent with HA processing of a speech-like stimulus with both adaptive features (acoustic feedback cancellation, digital noise reduction, microphone directionality) enabled and disabled, internal noise was quantified for various stimulus levels as the variance across repeated trials. Changes in noise level as a function of stimulus level demonstrated that (1) generation of internal noise is not isolated to the microphone, (2) noise may be dependent on input level, and (3) certain adaptive features may contribute to internal noise. Quantifying internal noise as the variance of the output measures allows for noise to be measured under real-world processing conditions, accounts for all sources of noise, and is predictive of internal noise audibility.
Skip Nav Destination
Article navigation
April 2010
April 05 2010
Measurement of hearing aid internal noisea) Available to Purchase
James D. Lewis;
James D. Lewis
c)
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242
Search for other works by this author on:
Shawn S. Goodman;
Shawn S. Goodman
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242
Search for other works by this author on:
Ruth A. Bentler
Ruth A. Bentler
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242
Search for other works by this author on:
James D. Lewis
c)
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242
Shawn S. Goodman
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242
Ruth A. Bentler
Department of Communication Sciences and Disorders,
University of Iowa
, Iowa City, Iowa 52242c)
Author to whom correspondence should be addressed. Electronic mail: [email protected]
a)
Portions of this work were presented at the annual convention of the American Acoustical Society, Scottsdale, Arizona, March 2008.
J. Acoust. Soc. Am. 127, 2521–2528 (2010)
Article history
Received:
October 14 2009
Accepted:
January 27 2010
Citation
James D. Lewis, Shawn S. Goodman, Ruth A. Bentler; Measurement of hearing aid internal noise. J. Acoust. Soc. Am. 1 April 2010; 127 (4): 2521–2528. https://doi.org/10.1121/1.3327808
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Climatic and economic fluctuations revealed by decadal ocean soundscapes
Vanessa M. ZoBell, Natalie Posdaljian, et al.
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
The contribution of speech rate, rhythm, and intonation to perceived non-nativeness in a speaker's native language
Ulrich Reubold, Robert Mayr, et al.
Related Content
The acoustic and perceptual effects of two noise-suppression algorithms
J. Acoust. Soc. Am. (January 2007)
Using a signal cancellation technique involving impulse response to assess directivity of hearing aids
J. Acoust. Soc. Am. (December 2009)
Modeling individual noise-induced hearing loss risk with proxy measurements of external-ear amplification
J. Acoust. Soc. Am. (June 2021)
Effects of in-the-ear microphone directionality on sound direction identification
J. Acoust. Soc. Am. (April 2008)
Predicting wideband real-ear-to-coupler differences in children using wideband acoustic immittance
J. Acoust. Soc. Am. (August 2023)