Hearing aid equivalent input noise (EIN) measures assume the primary source of internal noise to be located prior to amplification and to be constant regardless of input level. EIN will underestimate internal noise in the case that noise is generated following amplification. The present study investigated the internal noise levels of six hearing aids (HAs). Concurrent with HA processing of a speech-like stimulus with both adaptive features (acoustic feedback cancellation, digital noise reduction, microphone directionality) enabled and disabled, internal noise was quantified for various stimulus levels as the variance across repeated trials. Changes in noise level as a function of stimulus level demonstrated that (1) generation of internal noise is not isolated to the microphone, (2) noise may be dependent on input level, and (3) certain adaptive features may contribute to internal noise. Quantifying internal noise as the variance of the output measures allows for noise to be measured under real-world processing conditions, accounts for all sources of noise, and is predictive of internal noise audibility.

1.
Agnew
,
J.
(
1997
). “
Audible circuit noise in hearing aid amplifiers
,”
J. Acoust. Soc. Am.
102
,
2793
2799
.
2.
American National Standards Institute
(
2004
).
American National Standards Specification for Audiometers (ANSI S3.6–1996)
(
American National Standards Institute
,
New York
).
3.
American National Standards Institute
(
2004
).
American National Standards Specification of Hearing Aid Characteristics (ANSI S3.22–2004)
(
American National Standards Institute
,
New York
).
4.
Hellman
,
R.
, and
Zwicker
,
E.
(
1987
). “
Why can a decrease in dB (A) produce an increase in loudness?
,”
J. Acoust. Soc. Am.
82
,
1700
1705
.
5.
International Electrotechnical Commission
(
2008
).
Electroacoustics-Hearing Aids—Part 15: Methods for characterizing signal processing in hearing aids
(IEC 60118–15) (International Electrotechnical Commission, Geneva, Switzerland).
6.
Killion
,
M. C.
(
1976
). “
Noise of ears and microphones
,”
J. Acoust. Soc. Am.
59
,
424
433
.
7.
Lee
,
L. W.
, and
Geddes
,
E. R.
(
1998
). “
Perception of microphone noise in hearing instruments
,”
J. Acoust. Soc. Am.
104
,
3364
3367
.
8.
Nabelek
,
A. K.
,
Freyaldenhoven
,
M.
,
Tampas
,
J.
, and
Burchfield
,
S.
(
2006
). “
Acceptable noise level as a predictor of hearing aid use
,”
J. Am. Acad. Audiol
17
,
626
639
.
9.
Nabelek
,
A. K.
,
Tucker
,
F. M.
, and
Letowski
,
T. R.
(
1991
). “
Toleration of background noises: Relationship with patterns of hearing aid use by elderly persons
,”
J. Speech Hear. Res.
34
,
679
685
.
10.
Stuart
,
J. R.
(
1994
). “
Noise: Methods for estimating detectability and threshold
,”
J. Audio Eng. Soc.
42
,
124
140
.
11.
Thompson
,
S. C.
(
2003
). “
Internal noise in hearing aid microphones: Its causes and consequences
,”
Hear. J.
56
,
46
47
.
12.
Thompson
,
S. C.
,
LoPresti
,
J. L.
,
Ring
,
E. M.
,
Nepomunceno
,
H. G.
,
Beard
,
J. J.
,
Ballad
,
W. J.
, and
Carlson
,
E. V.
(
2002
). “
Noise in miniature microphones
,”
J. Acoust. Soc. Am.
111
,
861
866
.
You do not currently have access to this content.