Medical ultrasound scanners use high-energy pulses to probe the human body. The radiation force resulting from the impact of such pulses on an object can vibrate the object, producing a localized high-intensity sound in the audible range. Here, a theoretical model for the audio sound generated by ultrasound scanners is presented. This model describes the temporal and spectral characteristics of the sound. It has been shown that the sound has rich frequency components at the pulse repetition frequency and its harmonics. Experiments have been conducted in a water tank to measure the sound generated by a clinical ultrasound scanner in various operational modes. Results are in general agreement with the theory. It is shown that a typical ultrasound scanner with a typical spatial-peak pulse-average intensity value at 2 MHz may generate a localized sound-pressure level close to 100 dB relative to 20 μPa in the audible range under laboratory conditions. These findings suggest that fetuses may become exposed to a high-intensity audio sound during maternal ultrasound examinations. Therefore, contrary to common beliefs, ultrasound may not be considered a passive tool in fetal imaging.
Skip Nav Destination
Article navigation
March 2005
March 10 2005
Characteristics of the audio sound generated by ultrasound imaging systems Available to Purchase
Mostafa Fatemi;
Mostafa Fatemi
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
Search for other works by this author on:
Azra Alizad;
Azra Alizad
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
Search for other works by this author on:
James F. Greenleaf
James F. Greenleaf
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
Search for other works by this author on:
Mostafa Fatemi
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
Azra Alizad
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
James F. Greenleaf
Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
J. Acoust. Soc. Am. 117, 1448–1455 (2005)
Article history
Received:
May 10 2004
Accepted:
December 04 2004
Citation
Mostafa Fatemi, Azra Alizad, James F. Greenleaf; Characteristics of the audio sound generated by ultrasound imaging systems. J. Acoust. Soc. Am. 1 March 2005; 117 (3): 1448–1455. https://doi.org/10.1121/1.1852856
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Variation in global and intonational pitch settings among black and white speakers of Southern American English
Aini Li, Ruaridh Purse, et al.
The contribution of speech rate, rhythm, and intonation to perceived non-nativeness in a speaker's native language
Ulrich Reubold, Robert Mayr, et al.
Climatic and economic fluctuations revealed by decadal ocean soundscapes
Vanessa M. ZoBell, Natalie Posdaljian, et al.
Related Content
Behavioral Measurements of Absolute and Frequency‐Difference Thresholds in Guinea Pig
J. Acoust. Soc. Am. (June 1971)
High intensity focused ultrasound-induced gene activation in solid tumors
J. Acoust. Soc. Am. (July 2006)
Fast inverse scattering solutions using the distorted Born iterative method and the multilevel fast multipole algorithm
J. Acoust. Soc. Am. (August 2010)
Scattering calculation and image reconstruction using elevation-focused beams
J. Acoust. Soc. Am. (May 2009)