Extremely strong magnetic fields at the frequencies used in an electromagnetic articulometer (EMA) system may pose a risk to the health of a subject. To avoid such risks, the field strengths produced by any EMA system should be measured, and compared to published permissible exposure standards. This Letter reports measurements of the 2–50 kHz magnetic field strength of the Carstens Articulograph AG100. The measured field strength (35 μT at a distance of 7.5 cm) is permissible under local standards in Austria, Germany, the UK, and the USA (except Massachusetts), but may be impermissible under the 1995 European Community Prestandard, and in Canada.

1.
American College of Governmental Industrial Hygienists (1996). 1996 Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices (Cincinnati, OH).
2.
Canadian Ministry of National Health and Welfare (1993). Safety Code 6: Limits of Exposure to Radiofrequency Fields at Frequencies from 10 kHz–300 GHz, Catalog No. H46-2/90-160E (Canada Communication Group, Ottawa).
3.
Carstens Medizinelektronik GmbH (1993). Articulograph AG100 User’s Handbook (Göttingen).
4.
Commonwealth of Massachusetts Department of Labor and Industries (1997). “Nonionizing radiation limits for: The general public from non-occupational exposure to electromagnetic fields, employees from occupational exposure to electro-magnetic fields, & exposure from microwave ovens,” Code of Massachusetts Regulations 105 CMR 122.000 (Boston, MA).
5.
Foster, K. R. (1995). “Dielectric properties of tissues,” in The Biomedical Engineering Handbook, edited by J. D. Bronzino (CRC, Boca Raton, FL).
6.
Haes
,
D. L.
, and
Fitzgerald
,
M.
(
1995
). “
Video display terminal very low frequency measurements: The need for protocols in assessing VDT user ‘dose,’ 
Health Phys.
68
(
4
),
572
578
.
7.
Hoole, P., and Nguyen, N. (1996). “Electromagnetic articulography in coarticulation research,” in Instrumental Studies of Coarticulation, edited by W. J. Hardcastle and N. Hewlett (Cambridge U.P., Cambridge).
8.
(IEEE) (1992). ANSI Standard C95.1-1991, “IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz” (IEEE, New York).
9.
International Radiation Protection Association (1990). “Interim guidelines on limits of exposure to 50/60 Hz electric and magnetic fields,” Health Phys. 58(1), 113–122.
10.
Kavet
,
R
, and
Tell
,
R. A.
(
1991
). “
VDTs: Field levels, epidemiology, and laboratory studies
,”
Health Phys.
61
(
1
),
47
57
.
11.
Lindbohm
,
M-L.
,
Hietanen
,
M.
,
Kyyrönen
,
P.
,
Sallmén
,
M.
,
von Nandelstadh
,
M.
,
Taskinen
,
H.
,
Pekkarinen
,
M.
,
Ylikoski
,
M.
, and
Hemminki
,
K.
(
1992
). “
Magnetic fields of video display terminals and spontaneous abortion
,”
American Journal of Epidemiology
,
136
(
9
),
1041
1051
.
12.
Perkell
,
J. S.
,
Cohen
,
M.
,
Svirsky
,
M.
,
Matthies
,
M.
,
Garabieta
,
I.
, and
Jackson
,
M.
(
1992
). “
Electromagnetic midsagittal articulometer (EMMA) systems for transducing speech articulatory movements
,”
J. Acoust. Soc. Am.
92
,
3078
3096
.
13.
Polk, C., and Postow, E. (Eds.) (1996). Handbook of Biological Effects of Electromagnetic Fields (CRC, Boca Raton).
14.
Schönle
,
P. W.
,
Gräbe
,
K.
,
Wenig
,
P.
,
Höhne
,
J.
,
Schrader
,
J.
, and
Conrad
,
B.
(
1987
). “
Electromagnetic articulography: use of alternating magnetic fields for tracking movements of multiple points inside and outside the vocal tract
,”
Brain and Language
31
,
26
35
.
15.
Stuchly, M. A. (1995). “Low-frequency magnetic fields: Dosimetry, cellular, and animal effects,” in The Biomedical Engineering Handbook, edited by J. D. Bronzino (CRC, Boca Raton, FL).
16.
United States Air Force (1997). “Radio frequency radiation (RFR) safety program,” AFOSH Standard 48-9 (Washington, DC).
This content is only available via PDF.
You do not currently have access to this content.