Skip Nav Destination
Issues
Multiformat electronic cell sorting system: I. Theoretical considerations
Rev. Sci. Instrum. 55, 1044–1050 (1984)
https://doi.org/10.1063/1.1137898
Simple plethysmograph for measuring respiration rates in rats with lung damage
Rev. Sci. Instrum. 55, 1058–1060 (1984)
https://doi.org/10.1063/1.1137900
Characteristics of a hollow cathode ion source with magnetic multipole semicylindrical arc chamber
Rev. Sci. Instrum. 55, 1069–1073 (1984)
https://doi.org/10.1063/1.1137903
Generation of a modulated intense relativistic electron beam with a frequency tunable by a magnetic field
Rev. Sci. Instrum. 55, 1074–1076 (1984)
https://doi.org/10.1063/1.1137904
Hybrid absorber‐foil technique to measure the electron temperature of 0.1–10‐keV plasmas
Rev. Sci. Instrum. 55, 1077–1079 (1984)
https://doi.org/10.1063/1.1137885
Improving the energy‐transfer efficiency of opening switch tokamak Ohmic heating transformers
Rev. Sci. Instrum. 55, 1080–1083 (1984)
https://doi.org/10.1063/1.1137886
Low‐jitter, low‐inductance, electrically triggered spark gap
Rev. Sci. Instrum. 55, 1084–1089 (1984)
https://doi.org/10.1063/1.1137887
Traveling‐wave excitation of helical electrode TE N2 laser
Rev. Sci. Instrum. 55, 1094–1097 (1984)
https://doi.org/10.1063/1.1137889
High‐performance coaxial EPR cavity for investigations at elevated temperatures and pressures
Rev. Sci. Instrum. 55, 1104–1110 (1984)
https://doi.org/10.1063/1.1137892
Array‐processor‐based Fourier‐transform ion cyclotron resonance mass spectrometer
Rev. Sci. Instrum. 55, 1116–1119 (1984)
https://doi.org/10.1063/1.1137894
Electron beam induced current technique using a scanning Auger microprobe
Rev. Sci. Instrum. 55, 1129–1131 (1984)
https://doi.org/10.1063/1.1137905
Densimetry in compressed fluids by combining hydrostatic weighing and magnetic levitation
Rev. Sci. Instrum. 55, 1132–1142 (1984)
https://doi.org/10.1063/1.1137906
Microprocessor‐based controller for automatic amorphous silicon solar cells characterization
Rev. Sci. Instrum. 55, 1149–1153 (1984)
https://doi.org/10.1063/1.1137909
Selection of dwell time when using a lock‐in amplifier in a sequence of measurements
Rev. Sci. Instrum. 55, 1154–1156 (1984)
https://doi.org/10.1063/1.1137884
Modified automatic echo selection logic for ultrasonic attenuation measurement system
Rev. Sci. Instrum. 55, 1168–1169 (1984)
https://doi.org/10.1063/1.1137878
High‐temperature specimen holder for use with the PHI model 2100 specimen introduction/reaction chamber
Rev. Sci. Instrum. 55, 1171–1172 (1984)
https://doi.org/10.1063/1.1137880
Direct comparison of copper, silver, and palladium heat exchangers for cooling 3He
Rev. Sci. Instrum. 55, 1174–1176 (1984)
https://doi.org/10.1063/1.1137882
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.