We present a table-top setup for femtosecond time-resolved x-ray diffraction based on a Cu Kα (8.05 keV) laser driven plasma x-ray source. Due to its modular design, it provides high accessibility to its individual components (e.g., x-ray optics and sample environment). The Kα-yield of the source is optimized using a pre-pulse scheme. A magnifying multilayer x-ray mirror with Montel–Helios geometry is used to collect the emitted radiation, resulting in a quasi-collimated flux of more than 105 Cu Kα photons/pulse impinging on the sample under investigation at a repetition rate of 10 Hz. A gas ionization chamber detector is placed right after the x-ray mirror and used for the normalization of the diffraction signals, enabling the measurement of relative signal changes of less than 1% even at the given low repetition rate. Time-resolved diffraction experiments on laser-excited epitaxial Bi films serve as an example to demonstrate the capabilities of the setup. The setup can also be used for Debye–Scherrer type measurements on poly-crystalline samples.

The rapid development of ultrashort pulsed x-ray sources in recent decades has lead to spectacular progress in the field of ultrafast structural dynamics.1,2 The current state-of-the-art is set by accelerator-based x-ray free electron lasers (XFELs).3–5 While the extreme brilliance of these costly, large-scale-facility sources has opened up completely new possibilities, access is restricted and very competitive. Therefore, laboratory-scale, table-top x-ray sources, such as short pulse laser-driven plasmas, still represent an interesting alternative due to their low cost (as compared to XFELs), simplicity, versatility, and accessibility. In fact, the possibility to generate ultrashort hard x-ray pulses by using high intensity femtosecond laser pulses as a driver was one of the important enabling steps to establish the field. Many important ultrafast diffraction experiments have successfully been carried out with these sources,6–22 and since the first demonstration of sub-ps time resolution,6 they have been and are still being further developed, for example, towards higher repetition rates,23,24 better efficiency,25,26 or reaching higher photon energies.27,28

In a simplified view, the emission mechanism and the properties of ultrashort x-ray pulses from a fs laser driven plasma created at the surface of a solid target can be compared with x-ray production in an ordinary x-ray tube. However, instead of the static electric field in an x-ray tube, electrons of sufficiently high energy (tens of keV) are generated through the direct interaction of thermal plasma electrons with the high electrical field of the laser pulse (e.g., via resonance absorption) at intensities of 1016–1018 W/cm2. A fraction of those laser accelerated, hot electrons propagate into the cold, unexcited material underneath the surface plasma layer generating bremsstrahlung and characteristic line emission (e.g., Kα-emission). Therefore, the emitted x-ray pulses exhibit a short duration, which is determined by the duration of the driving laser pulse and the subsequent stopping time inside the material.29,30 Moreover, these pulses are perfectly suited for pump–probe type measurements since they are inherently synchronized to the drive laser. For time-resolved diffraction experiments, an optical pump-pulse is used for excitation while the ultrashort x-ray pulse monitors the transient structural changes induced by the pump by measuring the diffraction from the excited sample as a function of the time delay between the optical pump and the x-ray probe.

However, this type of source also shares the spatial properties of an ordinary x-ray tube, namely its incoherent emission into the full solid angle. Therefore, an appropriate x-ray optic, which collects and transfers an as high as possible amount of the emitted radiation onto the sample, is almost mandatory.31–37 

In this work, we present a compact and modular table-top setup based on a laser plasma Cu Kα x-ray source for time-resolved x-ray diffraction experiments. It employs a pre-pulse scheme to enhance the x-ray production,38 a magnifying Montel multilayer x-ray mirror39 to deliver a monochromatic and quasi-collimated beam to the sample, and a gas ionization detector for signal normalization. Its application is demonstrated by resolving the femtosecond structural dynamics in a laser-excited thin bismuth film.

The goal of this work was to construct a flexible and, at the same time, compact platform for time-resolved x-ray diffraction experiments. As such, it employs a design that separates the key components (e.g., x-ray source, x-ray optics, sample environment, and detector) into different modules, which can be individually modified/adapted to particular applications. A scheme of the setup is shown in Fig. 1.

FIG. 1.

Scheme of the modular setup based on a laser plasma Cu Kα x-ray source for time-resolved x-ray diffraction experiments.

FIG. 1.

Scheme of the modular setup based on a laser plasma Cu Kα x-ray source for time-resolved x-ray diffraction experiments.

Close modal

The laser driver for x-ray generation is a chirped-pulse-amplification titanium–sapphire laser system providing 120 fs pulses (stretched on purpose; see below) at a wavelength of 800 nm with a high laser-pulse contrast ratio (LPCR: 107 at 2 ps ahead of the pulse peak; >108 with respect to amplified spontaneous emission, ASE). Unlike many of the currently operating laser-driven plasma x-ray sources, which use 5–10 mJ, kHz repetition rate laser systems, we have opted for a high energy (150 mJ/pulse), low repetition rate (10 Hz) system. While the average x-ray flux (≈106 Kα-photons/s delivered to the sample; for details, see below) is comparable to these high repetition rate sources, the per-pulse flux is correspondingly (factor 100) higher.

Therefore, the same accumulated x-ray diffraction signal from a given sample can be obtained with less pulses. This enables experiments at relatively high optical pump fluences since optical damage at solid surfaces is often determined by accumulative effects and, thus, by the total optical dose. Consequently, less number of required pump–probe events automatically allows for higher pump fluences approaching or even exceeding the single-pulse melting threshold.11 

The main laser beam (the red optical path in Fig. 1) is split into three parts. A first holey mirror with a small central hole splits off ∼1.5 mJ of the main pulse energy, which serves as a plasma-generating pre-pulse to enhance x-ray generation.38 It is sent through an optical delay line (the pre-pulse delay unit in Fig. 1) and then recombined with the main beam by a second holey mirror. The pre- and main pulses are focused onto the surface of the x-ray target (copper tape) under an angle of incidence of 45° by a 30 cm focal length lens to intensities of 2 × 1014 and 1.6 × 1017 W/cm2, respectively. Due to the smaller diameter of the pre-pulse beam before the lens, its focus (∼80 μm FWHM) is larger than that of the main beam (25 μm FWHM), ensuring that the main pulse interacts with a laterally homogeneous pre-plasma.

After the recombining second holey mirror, a third holey mirror with an off-center hole splits off another fraction (about 1 mJ) from the main beam, which serves as the optical pump beam to excite the sample. It is focused with a lens of 1 m focal length onto the sample surface. The spot size of the focused pump beam can be adjusted by a diaphragm and monitored by a CCD camera positioned at a reference position equivalent to the sample plane. The energy of the pump beam is adjusted with a half-wave-plate in conjunction with a thin film polarizer and monitored with a PIN diode. This configuration can provide excitation fluences of more than 100 mJ/cm2, which, at 800 nm, is close to or beyond the melting threshold of many (in particular metallic) materials. A second optical delay line allows us to vary the time delay between the optical pump and the x-ray probe beam. The angle between the laser pump and the x-ray probe beam is set to be as small as possible (<10°).

The x-ray source is the only module that needs to operate under vacuum to avoid degradation of the spatial beam profile of the focused laser beam due to nonlinear effects in air. Therefore, the x-ray target (Cu tape) is mounted inside a vacuum chamber (working pressure 0.1 mbar). Part of the radiation emitted by the laser-generated plasma into the full solid angle leaves the vacuum chamber through a small hole covered with a thin Kapton foil. A multilayer x-ray optic is used to collect the radiation and to refocus it onto the sample under investigation.

A small ionization chamber detector (ICD) is located directly after the x-ray multilayer mirror. It is filled with Ar at a pressure of about 1 bar, and the charge signals generated by the x-ray induced ionization are used as a reference to normalize the diffraction signals on a pulse-to-pulse basis.

The sample under study needs to be placed in the focus of the multilayer x-ray optic. Depending on the particular application, the samples can be mounted on dedicated motorized sample stages with different linear and rotational degrees of freedom. This allows us to adjust the sample orientation with respect to the incoming x-ray beam as well as the beam position on the sample. Point as well as area x-ray detectors are available to record the x-ray signal diffracted/scattered by the sample.

In order to minimize losses by absorption of Cu Kα-radiation in air, the optics housing is purged with He, and He-purged beam-tubes (not shown in Fig. 1) are installed in the x-ray beam path towards the sample and the detector.

Here, we provide a detailed characterization of the different modules (source, x-ray optic, ICD, target environment, and detectors) with a particular emphasis on the relevant parameters that define the overall capabilities of the setup. We demonstrate that a full start-to-end design is key to achieving high flexibility and performance.

The vacuum chamber housing the x-ray source is very compact (size 24 × 30 × 30 cm3) and made of stainless steel, as shown in Fig. 2(a). To enhance the mechanical stability and to provide radiation shielding already close to the source, the chamber exhibits a wall thickness of 15 mm. 2 mm of lead are added to the inside of the chamber walls to further enhance the radiation shielding and also to reduce the level of background radiation that may reach the detector. Except in the direction of the x-ray probe beam, which exits the chamber through a 2 mm diameter Kapton window, this ensures a radiation level of less than 1 μSv/h at 10 cm distance from the chamber outer walls.

FIG. 2.

X-ray source vacuum chamber. (a) Inside view with the installed tape target assembly. Note the large amount of Cu debris caused by ablation from the Cu-tape. (b) Interaction area on the Cu tape target with a debris catcher foil (Kapton).

FIG. 2.

X-ray source vacuum chamber. (a) Inside view with the installed tape target assembly. Note the large amount of Cu debris caused by ablation from the Cu-tape. (b) Interaction area on the Cu tape target with a debris catcher foil (Kapton).

Close modal

The target consists of a 10 µm thick Cu tape mounted on a motorized spooling system, which has been developed at the Institute for Quantum Electronics of the Friedrich-Schiller-University Jena.40 The tape is continuously pulled with a speed of ∼8 mm/s to provide a non-irradiated surface area on the Cu tape for each impinging laser pulse. When the tape reaches its end, the pulling direction changes automatically and the tape is shifted, at the same time, perpendicular to its pulling direction by about 0.8 mm. A typical loading (Cu tape with 25 mm width and 15 m length) can provide more than 12 h of measurement time.

Debris from the ablated material represents a major challenge and requires regular cleaning of the chamber interior and the spooling system. Ablation occurs predominantly by the spallation of material at the back surface of the Cu tape upon reflection of the laser-induced shock wave.41 To directly catch most of the ejected material, a 8 µm thick Kapton foil is mounted together with the Cu tape to the spooling system so that they are simultaneously pulled with the same velocity. Close to the laser–target interaction point, the catcher foil is mechanically separated from the Cu tape by about 2 mm [see Fig. 2(b)].

To spectrally characterize the x-ray emission from the source, a thinned, back-illuminated CCD detector (Princeton Instruments MTE: 1300B) was used in photon counting mode so that a pulse-height analysis of the detected single-photon events provides the spectrum of the detected radiation.42,43 Figure 3(a) shows a typical single-pulse spectrum obtained in this way.

FIG. 3.

(a) Single-pulse emission spectrum of the x-ray source. (b) Measured Kα-yield (normalized) as a function of the position of the focusing lens (relative to the focus position) without (blue squares) and with a pre-pulse (arriving 5 ps before the main pulse; red circles); the dashed-dotted curves are guides to the eyes.

FIG. 3.

(a) Single-pulse emission spectrum of the x-ray source. (b) Measured Kα-yield (normalized) as a function of the position of the focusing lens (relative to the focus position) without (blue squares) and with a pre-pulse (arriving 5 ps before the main pulse; red circles); the dashed-dotted curves are guides to the eyes.

Close modal

The spectrum exhibits characteristic line radiation (e.g., Kα and Kβ) on a continuous bremsstrahlung background. Please note that part of the signal at lower energies (below the K-lines) is actually caused by Kα and Kβ photons with the x-ray generated charge distributed over more than one camera pixel.43 For the diffraction experiments, we employ the Kα-emission at 8.05 keV, which consists of the spin–orbit split Kα1 and Kα2 doublet (not resolved in Fig. 3).

The Kα-yield depends on laser (intensity) as well as on plasma (scale length of the spatial density profile) parameters.30,38 Therefore, to optimize Kα-generation, we vary the laser intensity by adjusting the laser pulse duration and the position of the focusing lens relative to the x-ray target. The plasma scale length is controlled through a suitable pre-pulse. Due to the high LPCR, we are in this way able to separate the processes of plasma formation/expansion and x-ray generation in a highly controllable fashion.

Figure 3(b) shows the measured Kα-yield (normalized) as a function of the relative lens position without pre-pulse (blue squares) and with a pre-pulse (red circles) arriving 5 ps before the main pulse. It can be clearly seen that proper adjustment of the lens position allows us to maximize the Kα-yield, a procedure that is regularly performed to maintain the source performance. In addition, to allow, at the same time, for a small x-ray source size, the optimum working point should be close to the actual focus position. Therefore, the laser pulses are on purpose not compressed to their bandwidth limit (<50 fs), but stretched pulses of about 100–120 fs duration are used.

The data shown in Fig. 3(b) also clearly show the effect of the pre-pulse, which allows us to increase the Kα-yield by about a factor of 2. Under optimized conditions and assuming spatially isotropic x-ray emission, we achieve a Kα-flux of 4 × 109 photons s−1 sr−1 without pre-pulse and 8 × 109 photons s−1 sr−1 with a pre-pulse at 110 mJ of energy in the main pulse impinging on the Cu tape (corresponding to 1.1 W of average drive laser power on target). This compares well with the reported yield of higher repetition rate sources and a few W drive power at 800 nm.24,26,44

As already mentioned, the x-ray emission from laser-produced plasmas occurs incoherently into the full solid angle. Therefore, a suitable x-ray optic is required to collect as much radiation as possible and guide it to the sample. For our setup, we have chosen a magnifying multilayer optic with Montel geometry39 (manufactured by Rigaku-OSMIC, Inc.). With a working distance of 100 mm to the source, it can be installed outside the vacuum chamber. The mirror exhibits a capture angle of 1.51° and a magnification of 5, resulting in a mirror-to-sample distance of 500 mm. The large mirror-to-sample distance gives sufficient space and, thus, great flexibility with respect to the sample environment (see Sec. III D). The multilayer coating is designed to reflect both the Cu Kα1 and Kα2 emission lines but suppresses other spectral components (i.e., Kβ). In order to minimize losses by absorption of Cu Kα-radiation in air, the housing of the Montel-optic is purged with He.

Figure 4 presents the results on the spatial characterization of the mirror. The image shown in Fig. 4(a) has been recorded with the x-ray CCD placed after the x-ray mirror (with the ICD removed) at a distance of 40 cm from the focus, and the x-ray flux is attenuated using suitable Al-filters. The beam exhibits a quadratic shape of 1.6 × 1.6 mm2, which is tilted by 45° with respect to the horizontal direction. Thus, it represents the topography, i.e., a map of the local reflectivity of the mirror, which appears very homogeneous. Moreover, the x-ray CCD allows for an absolute determination of the detected x-ray signal. Taking into account the known transmission of the Al-filters and the quantum efficiency of the CCD, we obtain that the reflected beam typically contains (1.3–1.5) × 105 Kα-photons/pulse (with a pre-pulse and a laser main pulse energy of 110 mJ on target).

FIG. 4.

(a) False color representation of the topography of the multilayer x-ray mirror measured a few cm behind the mirror. (b) Horizontal intensity profile as a function of convergence angle after integration of the image data shown in (a) in the vertical direction. (c) Intensity distribution in the focus of the mirror in false color representation (upper left). The graphs at the bottom and to the right represent the horizontal and vertical, respectively, cross sections, revealing an x-ray spot size (FWHM) of 138 μm (horizontal) and 120 μm (vertical).

FIG. 4.

(a) False color representation of the topography of the multilayer x-ray mirror measured a few cm behind the mirror. (b) Horizontal intensity profile as a function of convergence angle after integration of the image data shown in (a) in the vertical direction. (c) Intensity distribution in the focus of the mirror in false color representation (upper left). The graphs at the bottom and to the right represent the horizontal and vertical, respectively, cross sections, revealing an x-ray spot size (FWHM) of 138 μm (horizontal) and 120 μm (vertical).

Close modal

Since the distance of the detector to the focus point is known, the measured spatial intensity distribution in Fig. 4(a) allows us to calculate the angular properties of the focused beam. The measured size corresponds, therefore, to a small convergence angle of 1.6 × 10−5 sr (0.23° × 0.23°) and, thus, a quasi-collimated beam. Moreover, in the current setup, the horizontal direction represents the dispersion plane for experiments in Bragg-diffraction geometry. The resulting angular intensity profile (after integration along the vertical direction) is shown in Fig. 4(b). As expected, it is triangularly shaped and exhibits a FWHM of 0.17°.

Figure 4(c) depicts the measurements of the intensity distribution in the image/focal point of the mirror. It reveals a distortion free, smooth distribution and a slightly elliptical spot with a FWHM of 138 μm horizontally and 120 μm vertically [compare the cross sections in the horizontal (bottom) and vertical (right) directions]. This agrees with the expectations when considering the mirror magnification of 5 and the 25 μm FWHM of the laser focus on the Cu tape.

A low repetition rate system employing high energy laser pulses for x-ray generation has the advantage that the same accumulated diffraction signal can be measured with less x-ray pulses. This comes at the expense that the fluctuations of the x-ray flux delivered to the sample are averaged over a low number of events, thus leading to a larger measurement error for the diffraction signal.

Therefore, a pulse-to-pulse normalization scheme is desirable. For this purpose, we use a small ionization chamber, which is positioned after the x-ray mirror so that only the Kα-radiation, which is captured by the mirror and delivered to the sample, is monitored. The ICD is filled with Ar at a pressure of about 1 bar. A fraction of the Kα-radiation reflected from the mirror is absorbed by photo-ionizing the neutral Ar atoms. A total transmission of the ICD of 72% is measured, in agreement with the expected transmission value of 1.6 cm Ar at 1 bar and a total thickness of 16 µm of Kapton foil, which is used as a cell window. To collect the charge, a high bias voltage is applied (∼1900 kV). A high speed current amplifier with a gain of 105 is used to match the output signal of the ICD to the input of a gated charge-integrating analog-to-digital converter (ADC), which is used to digitize the charge signals.

The generated charge is directly proportional to the incidence x-ray flux as demonstrated by the data depicted in Fig. 5(a). It shows the dependence of the ICD-signal as a function of the transmitted x-ray flux. The latter has been measured with a phosphor-based x-ray area detector (see below), and each data point represents an average over 300 x-ray pulses.

FIG. 5.

(a) ICD-signal as a function of x-ray flux transmitted through the ICD (both quantities have been normalized to the corresponding maximum value). Each data point represents the average over 300 x-ray pulses. (b) ICD-signal (normalized) as a function of Ar-pressure in the cell.

FIG. 5.

(a) ICD-signal as a function of x-ray flux transmitted through the ICD (both quantities have been normalized to the corresponding maximum value). Each data point represents the average over 300 x-ray pulses. (b) ICD-signal (normalized) as a function of Ar-pressure in the cell.

Close modal

The data in Fig. 5(a) clearly show that the ICD-signal can be used to normalize the diffraction signal. However, it turned out that the generated signal exhibits a strong dependence on the Ar-pressure inside the ICD, as shown in Fig. 6(b). Pressure changes of less than 10 mbar lead to a change in the ICD-signal of almost 40%. Therefore, to keep the pressure inside the ICD constant and also to reduce the gas flow, a pressure control system, consisting of two pinhole valves at the entrance and exit, respectively, and a pressure gauge, has been added. It allows us to stabilize the pressure inside the ICD to better than ±0.1 mbar over “short” time scales of about 30 min. However, over longer time scales (hours), we observe drifts of the ICD-signal, which we attribute to slight changes in the pressure. Measures to mitigate these long-term drift effects will be discussed in Sec. III E.

FIG. 6.

Two sample stages for diffraction experiments under ambient conditions. (a): “Compact” sample stage designed for experiments under reversible excitation conditions, i.e., excitation fluences that do not lead to permanent modifications of the irradiated sample. (b) “Large” sample stage designed for high-fluence experiments, where laser irradiation leads to permanent changes in the sample and which, therefore, require sample exchange between two consecutive exposures. The different degrees of freedom are discussed in the main text.

FIG. 6.

Two sample stages for diffraction experiments under ambient conditions. (a): “Compact” sample stage designed for experiments under reversible excitation conditions, i.e., excitation fluences that do not lead to permanent modifications of the irradiated sample. (b) “Large” sample stage designed for high-fluence experiments, where laser irradiation leads to permanent changes in the sample and which, therefore, require sample exchange between two consecutive exposures. The different degrees of freedom are discussed in the main text.

Close modal

The relatively large distance between the (housing of the) x-ray mirror and its image/focus point of 40 cm provides great flexibility with respect to the sample environment. In our setup, we have realized two different sample stages dedicated for Bragg-diffraction type measurements under ambient conditions (i.e., in air, no heating or cooling option).

One is a relatively compact sample manipulator, which is used for experiments in a reversible excitation regime, where excitation fluences are sufficiently low so that no permanent sample modifications are induced by a single pulse, and a pulse-to-pulse sample exchange is, therefore, not necessary.

Figure 6(a) shows a photo of this sample stage, which has three linear degrees of motion (x, y, z). The x (5 cm travel range) and y (3 cm travel range) axes correspond to the motions in the sample plane and, thus, are used to adjust the position of the x-ray spot on the sample. The z-axis (5 cm travel range) allows us to bring the sample surface in the focus of the x-ray mirror. In addition, a single-circle goniometer with 100 mm diameter is mounted horizontally underneath the x–y–z stage and used to adjust the angle of incidence (θ) of the x-ray beam, e.g., adjustment of the Bragg-angle, while a smaller rotation stage is mounted on the y-stage to control the azimuthal orientation (φ) of the sample, which is, for example, needed to observe asymmetric reflections. All stages are stepper motor driven.

The second sample stage has been constructed for experiments in the irreversible excitation regime, i.e., excitation fluences are so high that even illumination with a single optical pump pulse leads to permanent modifications of the sample. As such, the sample has to be moved between consecutive exposures over distances of a few hundred µm (multiples of the pump beam spot size). This requires to move larger samples at velocities of a few cm/s with high accuracy.

Figure 6(b) shows this sample stage, which is much larger and exhibits more degrees of freedom. A high capacity two-axis translation stage with 15 mm motion range for both axes (labeled a and b) represents the base. The motion axes are oriented parallel and perpendicular to the x-ray probe beam direction. On this stage, a single-circle goniometer with a diameter of 290 mm is mounted horizontally and used to adjust the angle of incidence (θ) of the x-ray beam. The two-axis stage underneath allows us to bring the rotation axis of the goniometer exactly into the x-ray focus. The goniometer carries a three-axis sample mover with two axes (x and z) parallel to the goniometer plane and one axis (y) perpendicular to it. The x and y axes (155 mm travel range) correspond to the motions in the plane of the sample, and z (50 mm travel range) perpendicular to it. Therefore, z is used to bring the sample surface into the center of rotation, while x and y allow us to change the position on the sample. On the y-stage, another single-circle goniometer is mounted with the rotation axis parallel to z and, thus, perpendicular to the sample surface. It allows us to adjust the azimuthal orientation (φ) of the sample. Again, all these stages are stepper motor driven. In addition, a manual tip–tilt stage is used to precisely orient the sample surface parallel to the x–y motion plane, which is required to maintain the spatial overlap between the pump and the probe and to keep the sample in the center of rotation for large motion distances in x and y.

Both sample stages can be easily modified for a Debye–Scherrer transmission geometry by removing the φ-stage and replacing it with a sample mount, which is oriented perpendicular to the y-stage.

Other sample environments are possible and, in principle, easy to implement. For example, in-vacuum sample stages combined with heating and/or cooling would allow experiments at variable base temperatures.

Depending on the particular application, three different x-ray detectors are available to record the diffraction signals.

The first is a direct-detection, thinned, back-illuminated, slow-scan CCD (Princeton Instruments MTE: 1300B). The detector area is 26.8 × 26 mm2 with 1340 × 1300 pixels and 20 × 20 μm2 pixel size. While the quantum efficiency of this detector is rather low (18%) for Cu Kα-radiation, it provides single-photon sensitivity, low noise, low dark current (thus allowing longer integration times), and 16-bit dynamic range. Moreover, it can be used as an x-ray spectrometer with an energy resolution of about 0.24 keV (see Fig. 3), when operated in photon counting mode.

The second detector is also an area detector but uses an indirect-detection scheme. The incident x-rays are converted into visible photons using a scintillator, which are then amplified by a MCP and detected by a CCD. The available device (Photonic Science Gemstar HS) has an active area of 32 × 24 mm2 with 1392 × 1040 pixels and 23 × 23 μm2 effective pixel size. The scintillator output is 1:1 fiber-coupled to a gated, 40 mm diameter MCP-based image intensifier with variable gain. Coupling between the intensifier output screen and the CCD is achieved by a tapered fiber-optic so that the CCD is viewing a rectangular area with a diagonal of 40 mm on the intensifier input. This detector has a high quantum efficiency of 85% for Cu Kα-radiation, and the variable MCP gain allows for adaptation to the x-ray input level, reaching almost single photon sensitivity at high gain. Moreover, with 2 × 2 binning 10 Hz operation and thus single-pulse detection is possible.

The third detector is a single-channel detector based on a large-area (10 mm diameter) Si avalanche photodiode (API 394-70-74-591). It has a high sensitivity down to the single-photon level, a much faster read-out time allowing pulse-to-pulse data acquisition even at repetition rates much higher than 10 Hz, a compact size, and can be operated at room temperature (no cooling). Using the direct-detection CCD for calibration, a quantum efficiency of the avalanche photodiode (APD) for Cu Kα radiation of ∼40% was measured, in principal agreement with previously published data.45,46 Since the APD-signals are recorded and digitized with the same charge-integrating ADC as used for the ICD (and the laser reference diode), the APD output signal is first fed into a pulse-shaping amplifier (charge amplification of 11).

To characterize the performance of the APD its signal has been recorded for low x-ray input levels (1–3 photons/pulse) over a few thousand pulses for different bias voltages. Some results are depicted in Fig. 7. Figure 7(a) shows a histogram of the number of measured events as a function of APD-signal (given in ADC-units—adu) for a bias-voltage of 1.9 kV. The signal value distribution exhibits a multi-peak structure as it is expected for a Si-detector with its rather well-defined relation between the charge generated by a single x-ray photon and the photon energy (i.e., one Cu Kα photon produces 3.66 × 10−4 pCb). While the first peak corresponds to the dark current background (no photon detected, proven by blocking the incident x-rays), the second, third, fourth, and so on peaks correspond to one, two, three, and so on detected Kα-photons.

FIG. 7.

(a) Histogram of the APD-signal (given in ADC-units) at low incident x-ray flux measured over ∼10 min for a bias voltage of 1.9 kV. Red squares: measured data; blue solid curve: fit by a superposition of Gaussian functions (green dotted curves). The first, second, third, and so on peaks correspond to zero (i.e., dark current), one, two, and so on detected Kα-photons, respectively. (b) Integrated number of events as a function of Kα-photon number. Red open circles: experimental data; red dashed-dotted curve: fit by a Poisson distribution with an average number of 1.5 Kα-photons per pulse (excluding the zero-photon data point). (c) APD-signal (in ADC-units) per Kα-photon as a function of bias voltage (left axis) and APD-gain (right axis). The red dashed curve is a guide to the eyes; the red solid circle corresponds to a bias voltage of 1.9 kV, for which data are presented in (a) and (b).

FIG. 7.

(a) Histogram of the APD-signal (given in ADC-units) at low incident x-ray flux measured over ∼10 min for a bias voltage of 1.9 kV. Red squares: measured data; blue solid curve: fit by a superposition of Gaussian functions (green dotted curves). The first, second, third, and so on peaks correspond to zero (i.e., dark current), one, two, and so on detected Kα-photons, respectively. (b) Integrated number of events as a function of Kα-photon number. Red open circles: experimental data; red dashed-dotted curve: fit by a Poisson distribution with an average number of 1.5 Kα-photons per pulse (excluding the zero-photon data point). (c) APD-signal (in ADC-units) per Kα-photon as a function of bias voltage (left axis) and APD-gain (right axis). The red dashed curve is a guide to the eyes; the red solid circle corresponds to a bias voltage of 1.9 kV, for which data are presented in (a) and (b).

Close modal

A multi-peak fit (Gaussian) was applied to separate the individual contributions and to determine, in particular, the position of each peak. The latter exhibits a linear dependence as a function of photon number, resulting in an average signal of 67 adu per Kα-photon. Integrating the number of events under each peak, the total number of events as a function of photon number can be obtained, as depicted in Fig. 7(b). Excluding the zero-photon data point, the measured data (open circles) can be described by a Poisson-distribution with, on average, 1.5 Kα-photons detected per pulse (red dashed-dotted curve).

Figure 7(c) shows on the left ordinate the APD-signal per photon (in adu) as a function of bias voltage [the red solid circle corresponds to a bias voltage of 1.9 kV, for which the data are presented in Figs. 7(a) and 7(b)]. Knowing the number of primary electrons produced in the APD per Kα-photon, the gain of the pulse-shaping amplifier, and the sensitivity of the ADC (1 adu per 0.313 pCb), the APD-signal per Kα-photon can be converted into the APD-gain as shown on the right ordinate. In experiments with weak diffraction samples, resulting in typical signals of 5–30 detected photons per pulse, we operate the APD with bias voltages of 1.9 kV and above, corresponding to gain values of ∼500–1000.

FIG. 8.

Standard deviation of the measured diffraction signal for different signal levels (average number of detected photons per pulse) as a function of acquisition time. (a): Results for the chopping-scheme (see the text). (b) Results when using direct normalization with the ICD as a reference detector. The dashed-dotted curves represent the expected standard deviation when the measurement accuracy is limited by counting statistics (i.e., total number of detected photons).

FIG. 8.

Standard deviation of the measured diffraction signal for different signal levels (average number of detected photons per pulse) as a function of acquisition time. (a): Results for the chopping-scheme (see the text). (b) Results when using direct normalization with the ICD as a reference detector. The dashed-dotted curves represent the expected standard deviation when the measurement accuracy is limited by counting statistics (i.e., total number of detected photons).

Close modal

As already pointed out above, at a low repetition rate and measurements with a comparably low total number of pump–probe events, normalization is key to achieving a high measurement accuracy. For higher repetition rates (1 kHz), different schemes have been discussed in the literature,17,44,47,48 which depend also on the type of detector (e.g., its read-out speed). In particular, for single-channel detectors, such as the APD discussed here, normalization is usually achieved by chopping the optical pump beam at half the system repetition rate. As such, the detected signal is a sequence of alternating probe-only and pump–probe events and the accumulated signal of all pump–probe events is normalized to the accumulated signal of all probe-only events. Holtz et al. have analyzed in detail the noise characteristics using this chopping scheme for normalization and demonstrated almost shot-noise-limited performance.47 

For our low-repetition rate source, we have compared the chopping-scheme with the direct normalization using the ICD as a pulse-to-pulse reference. For this purpose, we recorded the APD-signal for different signal levels from a few detected photons per pulse up to ∼100 detected photons per pulse for about an hour (30 000–40 000 pulses), with and without the ICD in the beam path. Due to the finite x-ray transmission of the ICD (72%), the signals in the measurements without the ICD in the beam path were a factor of 1/0.72 ≈ 1.4 higher than with the ICD.

These datasets have then been divided into N bins of different number of events M (corresponding to a total acquisition time ta = M/10 Hz for one data point, for example, in a pump–probe experiment). Using the chopping-scheme, in each bin, the APD-signal of every second event is normalized to the APD-signal of the previous event. Then, all the single-pulse ratios in a bin are averaged and their normalized standard deviation ΔS/S is determined. Using direct normalization, the APD-signal of each pulse in a bin is normalized to the corresponding ICD-signal, and then, all APD/ICD ratios are averaged over all events in a bin, and subsequently, ΔS/S is determined.

Some results are depicted in Fig. 8, which shows the average normalized standard deviation 〈ΔS/SN for different signal levels nph (as given in the insets of Fig. 8) as a function of ta: (a) chopping-scheme and (b) direct normalization with ICD. The error bars represent the standard deviation of ΔS/S, and the different colors encode equivalent datasets with and without the ICD in the beam-path; e.g., red: seven detected photons per pulse without ICD in (a) correspond to five detected photons per pulse with ICD in (b). The dashed-dotted curves represent the expected ΔS/S assuming that the accuracy is limited by counting statistics and thus the total number of detected photons ntot per data point: ΔS/S=1/ntot.

First of all, the data in Fig. 8 clearly show that from the probe side, our setup allows for measurements with an accuracy only limited by counting statistics. Moreover, despite the 40% higher single-pulse signal nph for the chopping-scheme (no ICD in the beam path), a much larger acquisition time of almost a factor of 6 is needed to achieve the same accuracy as in a corresponding measurement with direct normalization (e.g., 1% at 23 phts/pulse with chopping: ≈360 s; 1% at 15 phts/pulse with direct normalization: ≈65 s).

This result is again fully in line with the expectations of a counting-statistics limited measurement. For the chopping-scheme, both the actual pump–probe signal and the probe-only normalization signal are limited by counting statistics and both are accumulated over only 50% of the total acquisition time tach. Therefore, with nach, the corresponding average number of detected photons per pulse ΔS/S can be expressed as
(1)
For direct normalization with the ICD as a reference, it must be noted that the ICD-signal corresponds to almost 3 × 104 Kα-photons per pulse and, therefore, its counting statistics does not limit the accuracy. Moreover, for an equivalent experimental situation, the average number of detected photons nad with the ICD in place is nad=0.72nach. This yields
(2)
The ratio tach/tad to achieve the same ΔS/S with the two normalization schemes is
(3)

Therefore, direct normalization with the ICD provides clear advantages over the chopping scheme, namely either a higher accuracy at a given acquisition time or a much shorter acquisition time for the same accuracy.

Laser-induced structural changes lead to distinct changes in diffraction signals, namely, changes in the shape and position of Bragg peaks due to strain and changes in the integrated diffraction efficiency due to variations in the structure factor. The scientific applications, for which the presented setup can be used best, are determined by the properties of the x-ray probe beam delivered to the sample by the multilayer x-ray mirror: (i) moderate monochromaticity of 2 × 10−3 (full Kα-bandwidth) and (ii) a relatively small convergence angle of 0.23° (quasi-collimated). For experiments on single-crystalline samples in Bragg-geometry, the setup lacks angular resolution and does not allow to observe small angular shifts or a subtle broadening of Bragg-peaks, making it unsuitable for the investigation of strain-related phenomena. In contrast, the high x-ray flux delivered to the sample and the demonstrated counting-statistics limited accuracy enable precise investigations of processes that lead only to structure factor changes and, thus, to variations in the integrated diffraction efficiency. Moreover, the quasi-collimated beam allows for Debye–Scherrer-type diffraction experiments in transmission geometry. Specific examples for both applications will be presented in the following.

A specific case where the structural changes upon laser-irradiation lead to changes in the structure factor alone is the excitation of coherent optical phonons in bismuth. It is well known that in Bi, the fully symmetric A1g optical mode can be excited in a coherent fashion through a mechanism called Displacive Excitation of Coherent Phonons (DECP).49 The A1g phonon modulates the distance of Bi atoms along the body-diagonal (111-direction) of the rhombohedral unit cell and, thus, the structure factor of all Bragg-reflections with a momentum transfer along (111). Time resolved x-ray diffraction has been used frequently to address this phenomenon.11,22,50–53

The high per-pulse x-ray flux of the current setup, which enables high accuracy measurements with a rather low number of pump–probe events and, thus, low accumulated optical dose (see Sec. II), allowed us to study DECP in bismuth in a high pump fluence regime, which had not been accessible before. While a detailed discussion of the results will be the topic of a separate publication, Fig. 10 depicts as an example data obtained on a 50 nm thick, (111)-oriented, epitaxial Bi-film grown on a (111)-oriented Si substrate.54 

Figure 9(a) shows the angular dependence (θ–2θ-scan) of the diffraction signal. It exhibits the (111) peaks of the Bi-film and the Si-substrate (normalized to the peak signal of the Bi-peak). The Si-peak is by a factor of 20 stronger than the Bi-reflection, which is expected because it is a bulk material and not a thin film. The widths of the Si- and Bi-peaks are ≈0.18° (FWHM) and ≈0.3° (FWHM), respectively. The measured width is determined by the angular width of the x-ray beam (0.17°), its spectral width (≈2.5 × 10−3), and the natural width of the particular Bragg-reflection. The spectral width makes only a small contribution (Δθ ≈ 0.03°–0.04°). Since the Si-substrate exhibits very high crystalline quality, its natural width is very small and can be neglected. Correspondingly, the measured width is essentially equal to the angular width of the x-ray probe beam at the sample. In contrast, the measured Bi-peak is significantly broader than both the natural width of a 50 nm Bi-film (≈0.08°) and the angular width of the x-ray beam. We attribute the additional broadening to the mosaic structure of the Bi-film. In the time-resolved diffraction experiment, the angle was adjusted to the maximum of the Bi-curve and the APD-detector positioned accordingly.

FIG. 9.

(a) Normalized θ–2θ-scan (rocking curve) of the 50 nm Bi(111) film grown on a Si(111) substrate (left Bi; right Si). (b) Diffraction signal of the Bi(111)-reflection as a function of time delay Δt between laser pump and x-ray probe normalized to the (averaged) diffraction signal measured at negative Δt for an incident pump fluence of 3 mJ/cm2; red circles: with normalization to the ICD-signal; gray squares: without normalization. (c) FFT (squared amplitude) of the measured signal for Δt > 0.3 ps.

FIG. 9.

(a) Normalized θ–2θ-scan (rocking curve) of the 50 nm Bi(111) film grown on a Si(111) substrate (left Bi; right Si). (b) Diffraction signal of the Bi(111)-reflection as a function of time delay Δt between laser pump and x-ray probe normalized to the (averaged) diffraction signal measured at negative Δt for an incident pump fluence of 3 mJ/cm2; red circles: with normalization to the ICD-signal; gray squares: without normalization. (c) FFT (squared amplitude) of the measured signal for Δt > 0.3 ps.

Close modal

Figure 9(b) shows the results of a time-resolved measurement with an incident pump fluence of 3 mJ/cm2. The diffraction signal, recorded on a single-pulse basis by the APD, corresponds to 10–20 detected photons per pulse and was integrated over 2 min per delay point to ensure that, in principle, an accuracy of ∼1% could be reached [compare Fig. 9(b)]. To account for any drifts on longer time scales (e.g., induced by small variations of the pressure in the ICD or of the spatial overlap of optical pump and x-ray probe on the sample), we adapted a “fast” scanning technique introduced for all-optical pump–probe experiments at high repetition rates.55 Instead of accumulating the signal for a given pump–probe delay time over 2 min at once and varying Δt sequentially, the full delay range was scanned multiple times (here 12×) with a short acquisition time per delay point (here 10 s).

The gray squares represent the obtained result without normalization of the measured diffraction signal to the corresponding ICD-signal. The red circles are obtained with normalization. For each scan, the diffraction signal was normalized on a pulse-to-pulse basis to the ICD-signal, averaged, and then re-normalized to the average signal measured for all negative Δt (i.e., representing the diffraction efficiency of the unexcited sample). Finally, all the re-normalized delay scans were averaged.

This comparison clearly demonstrates the need for and the effectiveness of the described normalization procedure. Despite a drop of the average diffraction signal at positive delay times, no clear transient changes are visible without normalization, in particular no oscillatory behavior, which may be attributed to the generation of coherent phonons. In contrast, the normalized data (red data points) exhibit a much larger drop of the average diffraction signal at positive time delays and, in particular, clear signal oscillations caused by the coherent excitation of the A1g optical mode.

Figure 9(c) depicts the squared amplitude of the Fourier-transform of the oscillatory part of the signal measured at positive time delays, revealing a dominant peak at a frequency of 2.53 THz. This value is significantly lower than the A1g phonon frequency of unexcited Bi of 2.92 THz at room temperature.56 Similar redshifts have been observed in many time-resolved optical57–59 and x-ray diffraction11,22,50,51,53 experiments on laser-excited Bi and can be readily explained by the changes of the inter-atomic potential (shift of the potential minimum and softening) upon optical/electronic excitation, which represent the basis of the DECP mechanism.

One may be tempted to attribute the second peak at 1.8 THz to the similarly redshifted Eg optical phonon modes of Bi. While these modes correspond to atomic motion perpendicular to the (111)-direction and the measured diffraction signal is not directly sensitive to this, it has been suggested that anharmonic interactions between the A1g and the Eg modes can lead to additional atomic motion along the (111) direction with the frequency of the Eg-mode.57,60 However, we refrain from interpreting the 1.8 THz peak in this way, since we observe in this measurement signal changes even at negative time delays, which we have to attribute to residual signal fluctuations/drifts that cannot be normalized by our procedure.

We use this measurement to comment on the temporal resolution of our setup. This is determined by the duration of the x-ray probe pulses and the geometry of the experiment (i.e., angle between the pump and the probe). For the results shown in Fig. 9(b) (Bragg angle 14.2°), the dominating factor is the geometry, which limits the temporal resolution to about 500 fs. Due to the good signal-to-noise ratio of the measurements, this still allows us to observe oscillatory signal components with frequencies up to at least 3 THz (data not shown here). It should also be noted that for the normal incidence Debye–Scherrer experiments discussed in Sec. III B, the geometrical contribution reduces to less than 10 fs. Therefore, it can be neglected and the temporal resolution of such experiments will be limited by the x-ray pulse duration, which, as discussed in the introduction, is determined by the duration of the driving laser pulse (here 120 fs) and the stopping time of energetic electrons in the x-ray target. For a 5 μm thick Cu tape as target, simulations30 predict a pulse duration of about 100 fs (FWHM), while published data16 obtained on other material systems exhibited measured response times well below 200 fs using a Cu tape of 10 μm thickness as x-ray target (same as in our setup).

One of the key properties of the x-ray beam delivered to the sample is its low convergence angle. This quasi-collimated x-ray probe beam in combination with the relatively low spectral bandwidth makes this setup also suited for Debye–Scherrer-type diffraction experiments on poly-crystalline materials and powders in transmission geometry using an area detector.16,17,33,34 Although the scattering signal is not localized in an intense diffraction spot, but distributed over a ring, this scheme has a number of advantages: (i) greater sample flexibility—no single-crystalline/epitaxial samples are required; (ii) simplicity—no precise sample adjustments (i.e., Bragg-angle) are necessary; and (iii) several Bragg-peaks can be recorded simultaneously.

Since we recently demonstrated the applicability of our setup for time-resolved Debye–Scherrer diffraction by analyzing the picosecond acoustic response of a 200 nm Au-film upon fs laser excitation,61 we will briefly discuss here only some results of static diffraction experiments.

Figure 10 shows, in the top row, the detector images measured on a 20 μm thick Cu-foil (a) and a free-standing 200 nm Au film supported by a Ni-mesh (b). Because of its larger size, we used the phosphor-based, MCP-amplified area detector (see Sec. III E) at high gain. The detector was placed close to the sample (normal distance l0 = 35 mm) and at an oblique angle (α = 28°) to the direction of the x-ray beam, to record as many diffraction orders as possible (covered range of scattering angels: 35°–85°). In both cases, the signal was accumulated over 3000 pulses (5 min exposure time).

FIG. 10.

Diffraction data obtained on poly-crystalline materials in transmission geometry. Top row: Detector images from (a) a 20 μm thick Cu-foil and (b) a free-standing, 200 nm thick Au-film supported by a Ni-mesh (in both cases accumulated over 3000 pulses). Bottom row: Corresponding scattering profiles Iq as a function of momentum transfer q=4πλsinθ2 (θ: scattering angle) after azimuthal integration of the diffraction images. (c) Different contributions to the total normalized momentum resolution Δq/q (red curve) due to (i) the divergence of the x-ray beam (blue curve), (ii) the x-ray spot size (green curve), and (iii) the bandwidth (orange curve). The gray squares and the violet diamond represent the measured (relative) peak widths of the three measured Cu reflections and the (220) Au reflection, respectively.

FIG. 10.

Diffraction data obtained on poly-crystalline materials in transmission geometry. Top row: Detector images from (a) a 20 μm thick Cu-foil and (b) a free-standing, 200 nm thick Au-film supported by a Ni-mesh (in both cases accumulated over 3000 pulses). Bottom row: Corresponding scattering profiles Iq as a function of momentum transfer q=4πλsinθ2 (θ: scattering angle) after azimuthal integration of the diffraction images. (c) Different contributions to the total normalized momentum resolution Δq/q (red curve) due to (i) the divergence of the x-ray beam (blue curve), (ii) the x-ray spot size (green curve), and (iii) the bandwidth (orange curve). The gray squares and the violet diamond represent the measured (relative) peak widths of the three measured Cu reflections and the (220) Au reflection, respectively.

Close modal

The bottom row shows the diffraction signal Iq as a function of momentum transfer q=4πλsinθ2 (θ: scattering angle) after azimuthal integration of the diffraction images. The individual Bragg-reflections are labeled with their respective Miller-indices (the scattering pattern of the Au-films contains weak scattering contributions from the Ni mesh).

An important performance measure is the momentum resolution Δq/q, which is determined in our setup by three different contributions: (i) the divergence of the beam Δθdiv = 0.17°, (ii) the projected x-ray spot size on the sample, and (iii) the spectral bandwidth. While (iii) makes a fixed contribution of Δq/qbw=ΔE/E=2.5×103, (i) depends on the scattering angle θ and (ii) depends on the scattering angle θ and the sample detector distance l0.

By differentiating Bragg’s law, contribution (i) can be determined as Δq/qdiv=Δθdiv/2tanθ/2. With θ0 = 90° − α, contribution (ii) can be written as Δq/qfoc=dcosθcosθθ02l0tanθ/2. The total momentum resolution Δq/q is then given by the convolution of (i) to (iii),
(4)

Quantitative estimates for our setup and the given detector geometry (l0 and α) are depicted in Fig. 10(c). The blue, green, and orange curves show the contributions due to the beam divergence Δq/qdiv, the spectral bandwidth Δq/qbw, and the x-ray spot size Δq/qfoc, respectively, while the red curve represents the total momentum resolution Δq/q. These results clearly show that over the covered q-range, the momentum resolution is essentially limited by the beam divergence, while the other effects make only minor contributions.

Figure 10(c) also shows the measured relative peak widths of the three Cu reflections (gray squares) and of the (220) Au reflections [violet diamond; the (200)- and (311)-reflections could not be properly analyzed due to the nearby Ni-reflections, as the (111)-reflection, which is partially cut], which are significantly larger than the limits set by the setup. We attribute this to the finite size of the crystalline grains. Using Scherrer’s equation (with a form factor K = 1), we estimate grain sizes of about 20–25 nm in line with the observation of smooth diffraction rings.

In summary, we have presented a compact and modular, and thus very flexible, setup for time-resolved x-ray diffraction using ultrashort Cu Kα x-ray pulses from a laser-produced plasma. The x-ray source employs a thin Cu-tape as target, which is excited by high energy (>100 mJ) laser pulses with a wavelength of 800 nm and a pulse duration of 110 fs at a repetition rate of 10 Hz. Using a pre-pulse scheme, an x-ray flux of about 1010 Kα photons per pulse (into the full solid angle) was achieved, of which about 105 are transferred onto the investigated sample in a quasi-collimated beam with a beam diameter of about 130 μm (FWHM) by means of a multilayer Montel mirror. An ionization chamber detector placed behind the x-ray mirror provides a normalization signal and allows us to achieve counting-statistics-limited measurement accuracy. Different area and single detectors as well as different sample stages can be used to adapt the setup to specific requirements. The characteristics and the overall performance of the setup have been demonstrated with test experiments in Bragg as well as in Debye–Scherrer geometry.

This work was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) Project No. 278162697-SFB 1242. We thank M. Kammler for the preparation of the Bi sample.

The authors have no conflicts to disclose.

W. Lu: Data curation (equal); Formal analysis (equal); Investigation (equal); Resources (equal); Software (lead); Writing – original draft (lead); Writing – review & editing (equal). M. Nicoul: Investigation (equal); Resources (equal). U. Shymanovich: Investigation (equal); Resources (equal). A. Tarasevitch: Resources (equal). M. Horn-von Hoegen: Resources (equal); Writing – review & editing (equal). D. von der Linde: Funding acquisition (equal); Supervision (equal). K. Sokolowski-Tinten: Conceptualization (equal); Formal analysis (equal); Funding acquisition (lead); Investigation (equal); Project administration (lead); Resources (lead); Supervision (lead); Writing – original draft (equal); Writing – review & editing (equal).

The data that support the findings of this study are available within the article.

1.
R.
Schoenlein
,
T.
Elsaesser
,
K.
Holldack
,
Z.
Huang
,
H.
Kapteyn
,
M.
Murnane
, and
M.
Woerner
,
Philos. Trans. R. Soc., A
377
,
20180384
(
2019
).
2.
T.
Elsaesser
and
M.
Woerner
,
J. Chem. Phys.
140
,
020901
(
2014
).
3.
C.
Bostedt
,
S.
Boutet
,
D. M.
Fritz
,
Z.
Huang
,
H. J.
Lee
,
H. T.
Lemke
,
A.
Robert
,
W. F.
Schlotter
,
J. J.
Turner
, and
G. J.
Williams
,
Rev. Mod. Phys.
88
,
015007
(
2016
).
6.
C.
Rischel
,
A.
Rousse
,
I.
Uschmann
,
P.-A.
Albouy
,
J.-P.
Geindre
,
P.
Audebert
,
J.-C.
Gauthier
,
E.
Fröster
,
J.-L.
Martin
, and
A.
Antonetti
,
Nature
390
,
490
(
1997
).
7.
C.
Rose-Petruck
,
R.
Jimenez
,
T.
Guo
,
A.
Cavalleri
,
C. W.
Siders
,
F.
Rksi
,
J. A.
Squier
,
B. C.
Walker
,
K. R.
Wilson
, and
C. P. J.
Barty
,
Nature
398
,
310
(
1999
).
8.
C. W.
Siders
,
A.
Cavalleri
,
K.
Sokolowski-Tinten
,
C.
Tóth
,
T.
Guo
,
M.
Kammler
,
M. H. V.
Hoegen
,
K. R.
Wilson
,
D. V. D.
Linde
, and
C. P. J.
Barty
,
Science
286
,
1340
(
1999
).
9.
A.
Rousse
,
C.
Rischel
,
S.
Fourmaux
,
I.
Uschmann
,
S.
Sebban
,
G.
Grillon
,
P.
Balcou
,
E.
Förster
,
J. P.
Geindre
,
P.
Audebert
,
J. C.
Gauthier
, and
D.
Hulin
,
Nature
410
,
65
(
2001
).
10.
K.
Sokolowski-Tinten
,
C.
Blome
,
C.
Dietrich
,
A.
Tarasevitch
,
M.
Horn von Hoegen
,
D.
von der Linde
,
A.
Cavalleri
,
J.
Squier
, and
M.
Kammler
,
Phys. Rev. Lett.
87
,
225701
(
2001
).
11.
K.
Sokolowski-Tinten
,
C.
Blome
,
J.
Blums
,
A.
Cavalleri
,
C.
Dietrich
,
A.
Tarasevitch
,
I.
Uschmann
,
E.
Förster
,
M.
Kammler
,
M.
Horn-von Hoegen
, and
D.
von der Linde
,
Nature
422
,
287
(
2003
).
12.
M.
Bargheer
,
N.
Zhavoronkov
,
Y.
Gritsai
,
J. C.
Woo
,
D. S.
Kim
,
M.
Woerner
, and
T.
Elsaesser
,
Science
306
,
1771
(
2004
).
13.
C. v.
Korff Schmising
,
M.
Bargheer
,
M.
Kiel
,
N.
Zhavoronkov
,
M.
Woerner
,
T.
Elsaesser
,
I.
Vrejoiu
,
D.
Hesse
, and
M.
Alexe
,
Phys. Rev. Lett.
98
,
257601
(
2007
).
14.
F.
Quirin
,
M.
Vattilana
,
U.
Shymanovich
,
A.-E.
El-Kamhawy
,
A.
Tarasevitch
,
J.
Hohlfeld
,
D.
von der Linde
, and
K.
Sokolowski-Tinten
,
Phys. Rev. B
85
,
020103
(
2012
).
15.
J.
Stingl
,
F.
Zamponi
,
B.
Freyer
,
M.
Woerner
,
T.
Elsaesser
, and
A.
Borgschulte
,
Phys. Rev. Lett.
109
,
147402
(
2012
).
16.
V.
Juve
,
M.
Holtz
,
F.
Zamponi
,
M.
Woerner
,
T.
Elsaesser
, and
A.
Borgschulte
,
Phys. Rev. Lett.
111
,
217401
(
2013
).
17.
M.
Holtz
,
C.
Hauf
,
A. A.
Hernández Salvador
,
R.
Costard
,
M.
Woerner
, and
T.
Elsaesser
,
Phys. Rev. B
94
,
104302
(
2016
).
18.
J.
Pudell
,
A. A.
Maznev
,
M.
Herzog
,
M.
Kronseder
,
C. H.
Back
,
G.
Malinowski
,
A.
von Reppert
, and
M.
Bargheer
,
Nat. Commun.
9
,
3335
(
2018
).
19.
A.
von Reppert
,
L.
Willig
,
J.-E.
Pudell
,
S. P.
Zeuschner
,
G.
Sellge
,
F.
Ganss
,
O.
Hellwig
,
J. A.
Arregi
,
V.
Uhlíř
,
A.
Crut
, and
M.
Bargheer
,
Sci. Adv.
6
,
eaba1142
(
2020
).
20.
M.
Mattern
,
A.
von Reppert
,
S.
Zeuschner
,
J.-E.
Pudell
,
F.
Kühne
,
D.
Diesing
,
M.
Herzog
, and
M.
Bargheer
,
Appl. Phys. Lett.
120
,
092401
(
2022
).
21.
S.
Priyadarshi
,
I.
González-Vallejo
,
C.
Hauf
,
K.
Reimann
,
M.
Woerner
, and
T.
Elsaesser
,
Phys. Rev. Lett.
128
,
136402
(
2022
).
22.
A.
Koç
,
I.
González-Vallejo
,
M.
Runge
,
A.
Ghalgaoui
,
K.
Reimann
,
L.
Kremeyer
,
F.
Thiemann
,
M. H. v.
Hoegen
,
K.
Sokolowski-Tinten
,
M.
Woerner
, and
T.
Elsaesser
,
Phys. Rev. B
107
,
L180303
(
2023
).
23.
N.
Zhavoronkov
,
Y.
Gritsai
,
M.
Bargheer
,
M.
Woerner
,
T.
Elsaesser
,
F.
Zamponi
,
I.
Uschmann
, and
E.
Förster
,
Opt. Lett.
30
,
1737
(
2005
).
24.
F.
Zamponi
,
Z.
Ansari
,
C. v.
Korff Schmising
,
P.
Rothhardt
,
N.
Zhavoronkov
,
M.
Woerner
,
T.
Elsaesser
,
M.
Bargheer
,
T.
Trobitzsch-Ryll
, and
M.
Haschke
,
Appl. Phys. A
96
,
51
(
2009
).
25.
J.
Weisshaupt
,
V.
Juvé
,
M.
Holtz
,
S.
Ku
,
M.
Woerner
,
T.
Elsaesser
,
S.
Ališauskas
,
A.
Pugžlys
, and
A.
Baltuška
,
Nat. Photonics
8
,
927
(
2014
).
26.
A.
Koç
,
C.
Hauf
,
M.
Woerner
,
L.
von Grafenstein
,
D.
Ueberschaer
,
M.
Bock
,
U.
Griebner
, and
T.
Elsaesser
,
Opt. Lett.
46
,
210
(
2021
).
27.
S.
Fourmaux
and
J. C.
Kieffer
,
Appl. Phys. B
122
,
162
(
2016
).
28.
Y.
Azamoum
,
R.
Clady
,
A.
Ferré
,
M.
Gambari
,
O.
Utéza
, and
M.
Sentis
,
Opt. Lett.
43
,
3574
(
2018
).
29.
P.
Gibbon
and
E.
Förster
,
Plasma Phys. Controlled Fusion
38
,
769
(
1996
).
30.
C.
Reich
,
P.
Gibbon
,
I.
Uschmann
, and
E.
Förster
,
Phys. Rev. Lett.
84
,
4846
(
2000
).
31.
M.
Bargheer
,
N.
Zhavoronkov
,
R.
Bruch
,
H.
Legall
,
H.
Stiel
,
M.
Woerner
, and
T.
Elsaesser
,
Appl. Phys. B
80
,
715
(
2005
).
32.
U.
Shymanovich
,
M.
Nicoul
,
K.
Sokolowski-Tinten
,
A.
Tarasevitch
,
C.
Michaelsen
, and
D.
von der Linde
,
Appl. Phys. B
92
,
493
(
2008
).
33.
U.
Shymanovich
,
M.
Nicoul
,
W.
Lu
,
S.
Kähle
,
A.
Tarasevitch
,
K.
Sokolowski-Tinten
, and
D.
von der Linde
,
Rev. Sci. Instrum.
80
,
083102
(
2009
).
34.
F.
Zamponi
,
Z.
Ansari
,
M.
Woerner
, and
T.
Elsaesser
,
Opt. Express
18
,
947
(
2010
).
35.
R.
Rathore
,
V.
Arora
,
H.
Singhal
,
T.
Mandal
,
J. A.
Chakera
, and
P. A.
Naik
,
Laser Part. Beams
35
,
442
(
2017
).
36.
M.
Schollmeier
,
T.
Ao
,
E. S.
Field
,
B. R.
Galloway
,
P.
Kalita
,
M. W.
Kimmel
,
D. V.
Morgan
,
P. K.
Rambo
,
J.
Schwarz
,
J. E.
Shores
,
I. C.
Smith
,
C. S.
Speas
,
J. F.
Benage
, and
J. L.
Porter
,
Rev. Sci. Instrum.
89
,
10F102
(
2018
).
37.
M.
Afshari
,
P.
Krumey
,
D.
Menn
,
M.
Nicoul
,
F.
Brinks
,
A.
Tarasevitch
, and
K.
Sokolowski-Tinten
,
Struct. Dyn.
7
,
014301
(
2020
).
38.
W.
Lu
,
M.
Nicoul
,
U.
Shymanovich
,
A.
Tarasevitch
,
P.
Zhou
,
K.
Sokolowski-Tinten
,
D.
von der Linde
,
M.
Mašek
,
P.
Gibbon
, and
U.
Teubner
,
Phys. Rev. E
80
,
026404
(
2009
).
40.
A.
Lübcke
, Ph.D. thesis,
Faculty of Physics and Astronomy, Friedrich-Schiller-Universität Jena
,
Jena
,
2007
.
41.
I.
Gilath
,
D.
Salzmann
,
M.
Givon
,
M.
Dariel
,
L.
Kornblit
, and
T.
Bar-Noy
,
J. Mater. Sci.
23
,
1825
(
1988
).
42.
L.
Labate
,
M.
Galimberti
,
A.
Giulietti
,
D.
Giulietti
,
L. A.
Gizzi
,
P.
Tomassini
, and
G.
Di Cocco
,
Nucl. Instrum. Methods Phys. Res., Sect. A
495
,
148
(
2002
).
43.
F.
Zamponi
,
T.
Kämpfer
,
A.
Morak
,
I.
Uschmann
, and
E.
Förster
,
Rev. Sci. Instrum.
76
,
116101
(
2005
).
44.
D.
Schick
,
A.
Bojahr
,
M.
Herzog
,
C.
von Korff Schmising
,
R.
Shayduk
,
W.
Leitenberger
,
P.
Gaal
, and
M.
Bargheer
,
Rev. Sci. Instrum.
83
,
025104
(
2012
).
45.
L. M. P.
Fernandes
,
F. D.
Amaro
,
A.
Antognini
,
J. M. R.
Cardoso
,
C. A. N.
Conde
,
O.
Huot
,
P. E.
Knowles
,
F.
Kottmann
,
J. A. M.
Lopes
,
L.
Ludhova
,
C. M. B.
Monteiro
,
F.
Mulhauser
,
R.
Pohl
,
J. M. F. d.
Santos
,
L. A.
Schaller
,
D.
Taqqu
, and
J. F. C. A.
Veloso
,
J. Instrum.
2
,
P08005
(
2007
).
46.
L. M. P.
Fernandes
,
J. A. M.
Lopes
,
J. M. F.
dos Santos
,
P. E.
Knowles
,
L.
Ludhova
,
F.
Mulhauser
,
F.
Kottmann
,
R.
Pohl
, and
D.
Taqqu
,
IEEE Trans. Nucl. Sci.
51
,
1575
(
2004
).
47.
M.
Holtz
,
C.
Hauf
,
J.
Weisshaupt
,
A. H.
Salvador
,
M.
Woerner
, and
T.
Elsaesser
,
Struct. Dyn.
4
,
054304
(
2017
).
48.
B.
Freyer
,
J.
Stingl
,
F.
Zamponi
,
M.
Woerner
, and
T.
Elsaesser
,
Opt. Express
19
,
015506
(
2011
).
49.
H. J.
Zeiger
,
J.
Vidal
,
T. K.
Cheng
,
E. P.
Ippen
,
G.
Dresselhaus
, and
M. S.
Dresselhaus
,
Phys. Rev. B
45
,
768
(
1992
).
50.
D. M.
Fritz
,
D. A.
Reis
,
B.
Adams
,
R. A.
Akre
,
J.
Arthur
,
C.
Blome
,
P. H.
Bucksbaum
,
A. L.
Cavalieri
,
S.
Engemann
,
S.
Fahy
,
R. W.
Falcone
,
P. H.
Fuoss
,
K. J.
Gaffney
,
M. J.
George
,
J.
Hajdu
,
M. P.
Hertlein
,
P. B.
Hillyard
,
M.
Horn-von Hoegen
,
M.
Kammler
,
J.
Kaspar
,
R.
Kienberger
,
P.
Krejcik
,
S. H.
Lee
,
A. M.
Lindenberg
,
B.
McFarland
,
D.
Meyer
,
T.
Montagne
,
E. D.
Murray
,
A. J.
Nelson
,
M.
Nicoul
,
R.
Pahl
,
J.
Rudati
,
H.
Schlarb
,
D. P.
Siddons
,
K.
Sokolowski-Tinten
,
T.
Tschentscher
,
D.
von der Linde
, and
J. B.
Hastings
,
Science
315
,
633
(
2007
).
51.
S. L.
Johnson
,
P.
Beaud
,
C. J.
Milne
,
F. S.
Krasniqi
,
E. S.
Zijlstra
,
M. E.
Garcia
,
M.
Kaiser
,
D.
Grolimund
,
R.
Abela
, and
G.
Ingold
,
Phys. Rev. Lett.
100
,
155501
(
2008
).
52.
S. L.
Johnson
,
P.
Beaud
,
E.
Vorobeva
,
C. J.
Milne
,
É. D.
Murray
,
S.
Fahy
, and
G.
Ingold
,
Phys. Rev. Lett.
102
,
175503
(
2009
).
53.
S. W.
Teitelbaum
,
T. C.
Henighan
,
H.
Liu
,
M. P.
Jiang
,
D.
Zhu
,
M.
Chollet
,
T.
Sato
,
É. D.
Murray
,
S.
Fahy
,
S.
O’Mahony
,
T. P.
Bailey
,
C.
Uher
,
M.
Trigo
, and
D. A.
Reis
,
Phys. Rev. B
103
,
L180101
(
2021
).
54.
M.
Kammler
and
M.
Horn-von Hoegen
,
Surf. Sci.
576
,
56
(
2005
).
55.
G. C.
Cho
,
W.
Kütt
, and
H.
Kurz
,
Phys. Rev. Lett.
65
,
764
(
1990
).
56.
J. S.
Lannin
,
J. M.
Calleja
, and
M.
Cardona
,
Phys. Rev. B
12
,
585
(
1975
).
57.
M.
Hase
,
M.
Kitajima
,
S.
Nakashima
, and
K.
Mizoguchi
,
Phys. Rev. Lett.
88
,
067401
(
2002
).
58.
É. D.
Murray
,
D. M.
Fritz
,
J. K.
Wahlstrand
,
S.
Fahy
, and
D. A.
Reis
,
Phys. Rev. B
72
,
060301(R)
(
2005
).
59.
S. W.
Teitelbaum
,
T.
Shin
,
J. W.
Wolfson
,
Y.-H.
Cheng
,
I. J.
Porter
,
M.
Kandyla
, and
K. A.
Nelson
,
Phys. Rev. X
8
,
031081
(
2018
).
60.
E. S.
Zijlstra
,
L. L.
Tatarinova
, and
M. E.
Garcia
,
Phys. Rev. B
74
,
220301(R)
(
2006
).
61.
W.
Lu
,
M.
Nicoul
,
U.
Shymanovich
,
F.
Brinks
,
M.
Afshari
,
A.
Tarasevitch
,
D.
von der Linde
, and
K.
Sokolowski-Tinten
,
AIP Adv.
10
,
035015
(
2020
).