We present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.
REFERENCES
1.
R.
Dörner
, V.
Mergel
, O.
Jagutzki
, L.
Spielberger
, J.
Ullrich
, R.
Moshammer
, and H.
Schmidt-Böcking
, “Cold target recoil ion momentum spectroscopy: A ‘momentum microscope’ to view atomic collision dynamics,” Phys. Rep.
330
, 95
–192
(2000
).2.
A. T. J. B.
Eppink
and D. H.
Parker
, “Velocity map imaging of ions and electrons using electrostatic lenses: Application in photoelectron and photofragment ion imaging of molecular oxygen,” Rev. Sci. Instrum.
68
, 3477
–3484
(1997
).3.
C. L.
Evans
and X. S.
Xie
, “Coherent anti-Stokes Raman scattering microscopy: Chemical imaging for biology and medicine,” Annu. Rev. Anal. Chem.
1
, 883
–909
(2008
).4.
G. W.
Fraser
, “Imaging in astrophysics (and elsewhere),” Nucl. Instrum. Methods Phys. Res., Sect. A
471
, 170
–173
(2001
).5.
C. D.
Ertley
, O. H. W.
Siegmund
, J.
Hull
, A.
Tremsin
, A.
O’Mahony
, C. A.
Craven
, and M. J.
Minot
, “Microchannel plate imaging detectors for high dynamic range applications,” IEEE Trans. Nucl. Sci.
64
, 1774
–1780
(2017
).6.
L.
Conti
, J.
Barnstedt
, L.
Hanke
, C.
Kalkuhl
, N.
Kappelmann
, T.
Rauch
, B.
Stelzer
, K.
Werner
, H.-R.
Elsener
, and D. M.
Schaadt
, “MCP detector development for UV space missions,” Astrophys. Space Sci.
363
, 63
(2018
).7.
S. W.
Hell
, “Toward fluorescence nanoscopy,” Nat. Biotechnol.
21
, 1347
–1355
(2003
).8.
T. C.
Williams
and C. R.
Shaddix
, “Simultaneous correction of flat field and nonlinearity response of intensified charge-coupled devices,” Rev. Sci. Instrum.
78
, 123702
(2007
).9.
A. S.
Tremsin
, J. B.
McPhate
, J. V.
Vallerga
, O. H. W.
Siegmund
, J. S.
Hull
, W. B.
Feller
, and E.
Lehmann
, “High-resolution neutron radiography with microchannel plates: Proof-of-principle experiments at PSI,” Nucl. Instrum. Methods Phys. Res., Sect. A
605
, 103
–106
(2009
).10.
J. L.
Wiza
et al., “Microchannel plate detectors,” Nucl. Instrum. Methods
162
, 587
–601
(1979
).11.
C. D.
Ertley
, O. H. W.
Siegmund
, S. R.
Jelinsky
, J.
Tedesco
, M. J.
Minot
, A.
O’Mahony
, C. A.
Craven
, M.
Popecki
, A. V.
Lyashenko
, and M. R.
Foley
, “Second generation large area microchannel plate flat panel phototubes,” Proc. SPIE
9915
, 99152G
(2016
).12.
A.
Zhao
, P.
Sándor
, and T.
Weinacht
, “Coincidence velocity map imaging using a single detector,” J. Chem. Phys.
147
, 013922
(2017
).13.
X.
Wang
, S. U.
Setru
, J.
Xie
, A.
Mane
, M.
Demarteau
, and R.
Wagner
, “Imaging of large-area microchannel plates using phosphor screens,” J. Instrum.
9
, P11011
(2014
).14.
J. R.
Kuhn
, H.
Lin
, and D.
Loranz
, “Gain calibrating nonuniform image-array data using only the image data,” Publ. Astron. Soc. Pac.
103
, 1097
(1991
).15.
P.
Boerner
, C.
Edwards
, J.
Lemen
, A.
Rausch
, C.
Schrijver
, R.
Shine
, L.
Shing
, R.
Stern
, T.
Tarbell
, A.
Title
, C. J.
Wolfson
et al., “Initial calibration of the Atmospheric Imaging Assembly (AIA) on the Solar Dynamics Observatory (SDO),” in The Solar Dynamics Observatory
(Springer
, 2011
), pp. 41
–66
.16.
N.
Kardjilov
, I.
Manke
, A.
Hilger
, M.
Strobl
, and J.
Banhart
, “Neutron imaging in materials science,” Mater. Today
14
, 248
–256
(2011
).17.
S.
Koutchmy
and A.
Verlhac
, “Photometric calibrations of an MCP space qualified photographic-camera,” Astron. Astrophys.
142
, 355
–360
(1985
).18.
R.
Hong
, A.
Leredde
, Y.
Bagdasarova
, X.
Fléchard
, A.
García
, P.
Müller
, A.
Knecht
, E.
Liénard
, M.
Kossin
, M. G.
Sternberg
et al., “High accuracy position response calibration method for a micro-channel plate ion detector,” Nucl. Instrum. Methods Phys. Res., Sect. A
835
, 42
–50
(2016
).19.
A. T.
Kenter
, J. H.
Chappell
, R. P.
Kraft
, G. R.
Meehan
, S. S.
Murray
, M. V.
Zombeck
, K. T.
Hole
, M.
Juda
, R. H.
Donnelly
, D.
Patnaude
et al., “In-flight performance and calibration of the Chandra high-resolution camera imager (HRC-I),” Proc. SPIE
4012
, 467
–492
(2000
).20.
A. T.
Kenter
, J. H.
Chappell
, K.
Kobayashi
, R. P.
Kraft
, G. R.
Meehan
, S. S.
Murray
, M. V.
Zombeck
, G. W.
Fraser
, J. F.
Pearson
, J. E.
Lees
et al., “Performance and calibration of the AXAF high-resolution camera I: Imaging readout,” Proc. SPIE
3114
, 26
–52
(1997
).21.
S. K.
Lee
, F.
Cudry
, Y. F.
Lin
, S.
Lingenfelter
, A. H.
Winney
, L.
Fan
, and W.
Li
, “Coincidence ion imaging with a fast frame camera,” Rev. Sci. Instrum.
85
, 123303
(2014
).22.
A. S.
Tremsin
and O. H. W.
Siegmund
, “Spatial distribution of electron cloud footprints from microchannel plates: Measurements and modeling,” Rev. Sci. Instrum.
70
, 3282
–3288
(1999
).23.
J.-J.
Berthelier
, J.-M.
Illiano
, D.
Nevejans
, E.
Neefs
, E.
Arijs
, and N.
Schoon
, “High resolution focal plane detector for a space-borne magnetic mass spectrometer,” Int. J. Mass Spectrom.
215
, 89
–100
(2002
).24.
J. H.
Chappell
and S. S.
Murray
, “Position Modelin!Oor the AXAF high resolution camera (HRC),” Proc. SPIE
1159
, 460
–475
(1989
).25.
J. L.
Krause
, K. J.
Schafer
, and K. C.
Kulander
, “High-order harmonic generation from atoms and ions in the high intensity regime,” Phys. Rev. Lett.
68
, 3535
(1992
).26.
A.
Zhao
, M.
van Beuzekom
, B.
Bouwens
, D.
Byelov
, I.
Chakaberia
, C.
Cheng
, E.
Maddox
, A.
Nomerotski
, P.
Svihra
, J.
Visser
, V.
Vrba
, and T.
Weinacht
, “Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution,” Rev. Sci. Instrum.
88
, 113104
(2017
).27.
A.
Nomerotski
, “Imaging and time stamping of photons with nanosecond resolution in Timepix based optical cameras,” Nucl. Instrum. Methods Phys. Res., Sect. A
937
, 26
–30
(2019
).28.
R.
Meier
and P.
Eberhardt
, “Velocity and ion species dependence of the gain of microchannel plates,” Int. J. Mass Spectrom. Ion Processes
123
, 19
–27
(1993
).29.
A.
Mathew
, G. B.
Eijkel
, I. G. M.
Anthony
, S. R.
Ellis
, and R. M. A.
Heeren
, “Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal-time-of-flight mass spectrometry using a Timepix detector,” J. Mass Spectrom.
57
, e4820
(2022
).30.
X.
Llopart
, R.
Ballabriga
, M.
Campbell
, L.
Tlustos
, and W.
Wong
, “Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements,” Nucl. Instrum. Methods Phys. Res., Sect. A
581
, 485
–494
(2007
).31.
C.
Cheng
, G.
Moğol
, T.
Weinacht
, A.
Nomerotski
, and C.
Trallero-Herrero
, “3D velocity map imaging of electrons with TPX3CAM,” Rev. Sci. Instrum.
93
, 013003
(2022
).32.
B. R.
Sandel
, A. L.
Broadfoot
, and D. E.
Shemansky
, “Microchannel plate life tests,” Appl. Opt.
16
, 1435
–1437
(1977
).33.
S.
Matsuura
, S.
Umebayashi
, C.
Okuyama
, and K.
Oba
, “Characteristics of the newly developed MCP and its assembly,” IEEE Trans. Nucl. Sci.
32
, 350
–354
(1985
).34.
D. T.
Hall
, “Ultraviolet resonance radiation and the structure of the heliosphere,” Ph.D. thesis, The University of Arizona
, 1992
.35.
O. H. W.
Siegmund
, “Preconditioning of microchannel plate stacks,” Proc. SPIE
1072
, 111
–118
(1989
).© 2022 Author(s). Published under an exclusive license by AIP Publishing.
2022
Author(s)
You do not currently have access to this content.