Triggered gas switches with trigger electrodes, such as three-electrode spark switches and trigatron type spark switches, have been widely used in repetitive operating Marx generators due to their large current flowing capability. However, the ablation of trigger electrodes during repetitive operation is inevitable, which reduces the working life of triggered gas switches. In this paper, we introduced an over-voltage triggering method for two-electrode spark switches by replacing one of the charging inductors of the Marx generator with a pulse generator. The experimental results showed that a high-voltage trigger pulse with an amplitude of 60 kV and a rising speed of 7.65 kV/100 ns was obtained from a single stackable module with a 12 V lithium battery pack as the energy source. Due to the absence of trigger electrodes, the triggering method is beneficial to extend the lifetime of switches and realize a maintenance-free repetitive operating Marx generator.

1.
G.
Mesyats
,
Pulsed Power
(
Springer
,
Berlin
,
2004
).
2.
R.
Pecquois
,
L.
Pecastaing
,
M.
Rivaletto
,
A. S.
De Ferron
, and
R.
Vezinet
, “
MOUNA: An autonomous, compact, high-power, and wideband electromagnetic source based on a novel resonant pulsed transformer
,”
IEEE Trans. Plasma Sci.
40
,
1407
1415
(
2012
).
3.
G.
Winands
,
Z.
Liu
,
A.
Pemen
 et al., “
Long lifetime, triggered spark-gap switch for repetitive pulsed power applications
,”
Rev. Sci. Instrum.
76
,
085107
(
2005
).
4.
D.
Bhasavanich
,
S. S.
Hitchcock
, and
P. M.
Creel
, “
Development of a compact, high-energy spark gap switch and trigger generator system
,” in
IEEE International Pulsed Power Conference
(
IEEE
,
1991
), pp.
343
345
.
5.
C. M.
Xie
,
X. H.
Tan
, and
T.
Du
, “
Research on electrode ablation of gas spark switch
,”
High Power Laser Part. Beams
26
,
248
255
(
2014
).
6.
M. B.
He
,
T.
Li
,
G. H.
Wu
,
C.
Jiang
, and
Z. P.
Li
, “
Trigger system of two-electrode gas spark switch
,”
High Power Laser Part Beams
6
,
951
955
(
2009
).
7.
M.
Sack
,
C.
Schultheiss
, and
H.
Bluhm
, “
Wear-less trigger method for Marx generators in repetitive operation
,” in
14th IEEE International Pulsed Power Conference
(
IEEE
,
2003
), pp.
1415
1418
.
8.
L.
Yang
,
L.
Cheng
,
J. J.
Huang
,
D. G.
Lai
,
S. Q.
Ren
,
Y. Y.
Zhang
, and
Y. M.
Zhang
, “
The synchronous triggering system of the gas main switch of the flash No. 2 accelerator
,”
High Power Laser Part. Beams
019
(
6
),
997
1000
(
2006
).
9.
R.
Chen
,
J. H.
Yang
,
X. B.
Cheng
, and
B. L.
Qian
, “
Preliminary study of all solid-state pulse drive source based on fractional ratio saturable pulse transformer
,”
High Power Laser Part. Beams
32
(
2
),
50
55
(
2020
).
10.
J. Y.
Geng
,
Research on Low Jitter Triggered Main Switch and Trigger Pulse
(
The University of Defense Technology
,
2018
) (in Chinese).
11.
M.
Sack
and
G.
Mueller
,
Testing of a modular over-voltage trigger device for Marx generators
, in
2014 International Conference on Optimization of Electrical and Electronic Equipment(OPTIM)
(
IEEE
,
2014
), pp.
33
34
.
You do not currently have access to this content.