Spectroscopy in vacuum ultraviolet (VUV) and visible ranges plays an important role in the investigation and diagnosis of tokamak plasmas. However, under harsh environmental conditions of fusion grade devices, such as ITER, VUV–visible systems encounter many issues due to the degradation of optical components used in such systems. Here, near-infrared (NIR) spectroscopy has become an effective tool in understanding the edge plasma dynamics. Considering its importance, a NIR spectroscopic diagnostic has been developed and installed on the ADITYA-U tokamak. The system consists of a 0.5 m spectrometer having three gratings with different groove densities, and it is coupled with a linear InGaAs photodiode array. Radiation from the ADITYA-U edge plasma has been collected using a collimating lens and optical fiber combination and transported to the spectrometer. The spectrum in the NIR range from the ADITYA-U plasma has been recorded using this system, in which Paβ and Paγ along with many spectral lines from neutral and singly ionized impurities have been observed. The influxes of H and C have been estimated from measurements. The H influx value is found to be 2.8 × 1016 and 1.9 × 1016 particles cm−2 s−1 from neutral hydrogen lines Hα and Paβ, respectively, and the C influx value is found to be 3.5 × 1015 and 2.9 × 1015 particles cm−2 s−1 from the neutral carbon and singly ionized carbon, respectively. A good agreement is seen between these results and the results obtained by using a routine photomultiplier tube based diagnostic.
Skip Nav Destination
Article navigation
November 2022
Research Article|
November 18 2022
Initial results from near-infrared spectroscopy on ADITYA-U tokamak
N. Ramaiya
;
N. Ramaiya
a)
(Formal analysis, Investigation, Writing - original draft)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
a)Author to whom correspondence should be addressed: nilam@ipr.res.in
Search for other works by this author on:
R. Manchanda;
R. Manchanda
(Conceptualization)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
M. B. Chowdhuri
;
M. B. Chowdhuri
(Methodology)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
N. Yadava
;
N. Yadava
(Validation)
2
Institute of Science, Nirma University
, Ahmedabad 382 481, India
Search for other works by this author on:
R. Dey;
R. Dey
(Software)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
A. Kumar;
A. Kumar
(Investigation)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
3
Homi Bhabha National Institute
, Mumbai 400 094, India
Search for other works by this author on:
K. Shah
;
K. Shah
(Data curation)
4
Department of Physics, Pandit Deendayal Energy University
, Raisan, Gandhinagar 382 007, India
Search for other works by this author on:
S. Patel;
S. Patel
(Validation)
4
Department of Physics, Pandit Deendayal Energy University
, Raisan, Gandhinagar 382 007, India
Search for other works by this author on:
K. A. Jadeja
;
K. A. Jadeja
(Investigation)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
K. M. Patel;
K. M. Patel
(Investigation)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
R. Kumar
;
R. Kumar
(Investigation)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
S. Aich;
S. Aich
(Investigation)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
S. K. Pathak;
S. K. Pathak
(Resources)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
3
Homi Bhabha National Institute
, Mumbai 400 094, India
Search for other works by this author on:
R. L. Tanna;
R. L. Tanna
(Visualization)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
Search for other works by this author on:
J. Ghosh;
J. Ghosh
(Writing – review & editing)
1
Institute for Plasma Research
, Bhat, Gandhinagar 382 428, India
3
Homi Bhabha National Institute
, Mumbai 400 094, India
Search for other works by this author on:
a)Author to whom correspondence should be addressed: nilam@ipr.res.in
b)
R. L Tanna et al., Nucl. Fusion 57, 102008 (2017).
Note: This paper is part of the Special Topic on Proceedings of the 24th Topical Conference on High-Temperature Plasma Diagnostics.
Rev. Sci. Instrum. 93, 113552 (2022)
Article history
Received:
June 03 2022
Accepted:
September 12 2022
Citation
N. Ramaiya, R. Manchanda, M. B. Chowdhuri, N. Yadava, R. Dey, A. Kumar, K. Shah, S. Patel, K. A. Jadeja, K. M. Patel, R. Kumar, S. Aich, S. K. Pathak, R. L. Tanna, J. Ghosh, ADITYA-U team; Initial results from near-infrared spectroscopy on ADITYA-U tokamak. Rev. Sci. Instrum. 1 November 2022; 93 (11): 113552. https://doi.org/10.1063/5.0101850
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
292
Views