The Banc d’Etude et de Tests des Sources d’Ions (BETSI) test bench was built in 2009 for the Spiral2 project. Year after year, upgrades were done on the low energy beam line in order to have a complete injector equipped with 2 solenoids and vacuum chambers with multiple viewports for various kinds of beam-diagnostics. BETSI was designed for a 50 kV high voltage, and all the sources that were installed on the platform were also designed for that voltage. As the advanced light ion source extraction system ions source family is getting larger, the design is made for higher extraction voltages. As the common extraction voltage is 100 kV, the BETSI platform was upgraded to this voltage value. The control-command was upgraded, and at this voltage, a great care on the electromagnetic protections was taken in order to protect the equipment when spark occurs. This paper describes the choice of the upgrade, its installation, and some performances already obtained with a permanent magnet ion source equipped with a large accelerating tube.
Skip Nav Destination
Article navigation
November 2019
Research Article|
November 06 2019
Preliminary results of BETSI test bench upgrade at CEA-Saclay
Special Collection:
Proceedings of the 18th International Conference on Ion Sources
O. Tuske;
O. Tuske
a)
IRFU, CEA, Université Paris-Saclay
, F91191 Gif-sur-Yvette, France
Search for other works by this author on:
O. Delferrière;
O. Delferrière
IRFU, CEA, Université Paris-Saclay
, F91191 Gif-sur-Yvette, France
Search for other works by this author on:
Y. Gauthier;
Y. Gauthier
IRFU, CEA, Université Paris-Saclay
, F91191 Gif-sur-Yvette, France
Search for other works by this author on:
F. Harrault;
F. Harrault
IRFU, CEA, Université Paris-Saclay
, F91191 Gif-sur-Yvette, France
Search for other works by this author on:
Y. Sauce
Y. Sauce
IRFU, CEA, Université Paris-Saclay
, F91191 Gif-sur-Yvette, France
Search for other works by this author on:
Note: Contributed paper, published as part of the Proceedings of the 18th International Conference on Ion Sources, Lanzhou, China, September 2019.
Rev. Sci. Instrum. 90, 113305 (2019)
Article history
Received:
September 04 2019
Accepted:
October 20 2019
Citation
O. Tuske, O. Delferrière, Y. Gauthier, F. Harrault, Y. Sauce; Preliminary results of BETSI test bench upgrade at CEA-Saclay. Rev. Sci. Instrum. 1 November 2019; 90 (11): 113305. https://doi.org/10.1063/1.5126634
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
216
Views
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
Related Content
BETSI, a new test bench for ion sources optimization at CEA SACLAY
Rev. Sci. Instrum. (February 2008)
Plasma studies on electron cyclotron resonance light ion source at CEA/Saclay
Rev. Sci. Instrum. (February 2012)
ECRIN and MultiCusp Sources at CEA Saclay
AIP Conference Proceedings (August 2007)
Electron cyclotron resonance 140 mA D + beam extraction optimization for IFMIF EVEDA accelerator
Rev. Sci. Instrum. (February 2008)
Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay
Rev. Sci. Instrum. (February 2012)