The ITER neutral beam system will be equipped with large radio frequency (RF) driven negative ion sources, with a cross section of 0.9 m × 1.9 m, which have to deliver extracted D− ion beams of 57 A at 1 MeV for 1 h. On the extraction from a large ion source experiment test facility, a source of half of this size is being operational since 2013. The goal of this experiment is to demonstrate a high operational reliability and to achieve the extracted current densities and beam properties required for ITER. Technical improvements of the source design and the RF system were necessary to provide reliable operation in steady state with an RF power of up to 300 kW. While in short pulses the required D− current density has almost been reached, the performance in long pulses is determined in particular in Deuterium by inhomogeneous and unstable currents of co-extracted electrons. By application of refined caesium evaporation and distribution procedures, and reduction and symmetrization of the electron currents, considerable progress has been made and up to 190 A/m2 D−, corresponding to 66% of the value required for ITER, have been extracted for 45 min.
Skip Nav Destination
Article navigation
May 2018
Research Article|
April 30 2018
Deuterium results at the negative ion source test facility ELISE
Special Collection:
17th International Conference on Ion Sources
W. Kraus
;
W. Kraus
a)
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
a)Author to whom correspondence should be addressed: [email protected]
Search for other works by this author on:
D. Wünderlich;
D. Wünderlich
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
Search for other works by this author on:
U. Fantz
;
U. Fantz
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
Search for other works by this author on:
B. Heinemann;
B. Heinemann
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
Search for other works by this author on:
F. Bonomo;
F. Bonomo
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
Search for other works by this author on:
R. Riedl
R. Riedl
Max-Planck-Institut für Plasmaphysik
, Garching, Germany
Search for other works by this author on:
a)Author to whom correspondence should be addressed: [email protected]
Rev. Sci. Instrum. 89, 052102 (2018)
Article history
Received:
November 07 2017
Accepted:
November 27 2017
Citation
W. Kraus, D. Wünderlich, U. Fantz, B. Heinemann, F. Bonomo, R. Riedl; Deuterium results at the negative ion source test facility ELISE. Rev. Sci. Instrum. 1 May 2018; 89 (5): 052102. https://doi.org/10.1063/1.5012591
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Implementation of simultaneous ultraviolet/visible and x-ray absorption spectroscopy with microfluidics
Olivia McCubbin Stepanic, Christopher J. Pollock, et al.
Related Content
Current status and highlights of the ELI-NP research program
Matter Radiat. Extremes (March 2020)
Improved understanding of the Cs dynamics in large H− sources by combining TDLAS measurements and modeling
AIP Conf. Proc. (September 2018)
Negative hydrogen ion production mechanisms
Appl. Phys. Rev. (June 2015)
Characteristics microstructure and microhardness of cast Ti-6Al-4V ELI for biomedical application submitted to solution treatment
AIP Conference Proceedings (May 2018)
Photoneutron measurements in the GDR region at ELI-NP
AIP Conf. Proc. (February 2019)