In this paper, we describe a novel solution to increase the speed of Time-Correlated Single Photon Counting (TCSPC) measurements by almost an order of magnitude while providing, in principle, zero distortion regardless of the experimental conditions. Typically, the relatively long dead time associated with the conversion electronics requires a proper tune of the excitation power in order to avoid distortions of the reconstructed waveform due to pileup and counting loss. As a result, the maximum operating rate of a TCSPC channel is now limited between 1% and 5% of the excitation frequency, thus leading to relatively long acquisition times. We show that negligible distortion (below 1%) is guaranteed if the dead time associated with the converter is kept below the dead time of the detector, and at the same time the detector dead time is matched to the duration of the excitation period. In this way, unprecedented high-speed operation is possible. In this paper, we provide a theoretical analysis of the technique, including the main non-idealities which are introduced by a generic physical implementation. The results are supported by both numerical simulations and analytical calculations.
Skip Nav Destination
High-speed and low-distortion solution for time-correlated single photon counting measurements: A theoretical analysis
Article navigation
December 2017
Research Article|
December 04 2017
High-speed and low-distortion solution for time-correlated single photon counting measurements: A theoretical analysis
A. Cominelli
;
A. Cominelli
a)
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria (DEIB)
, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
Search for other works by this author on:
G. Acconcia
;
G. Acconcia
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria (DEIB)
, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
Search for other works by this author on:
P. Peronio
;
P. Peronio
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria (DEIB)
, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
Search for other works by this author on:
M. Ghioni;
M. Ghioni
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria (DEIB)
, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
Search for other works by this author on:
I. Rech
I. Rech
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria (DEIB)
, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
Search for other works by this author on:
Rev. Sci. Instrum. 88, 123701 (2017)
Article history
Received:
July 18 2017
Accepted:
November 08 2017
Citation
A. Cominelli, G. Acconcia, P. Peronio, M. Ghioni, I. Rech; High-speed and low-distortion solution for time-correlated single photon counting measurements: A theoretical analysis. Rev. Sci. Instrum. 1 December 2017; 88 (12): 123701. https://doi.org/10.1063/1.4996690
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
Multiplexed single‐photon counting. II. The statistical theory of time‐correlated measurements
Rev Sci Instrum (June 1996)
A wide-field TCSPC FLIM system based on an MCP PMT with a delay-line anode
Rev. Sci. Instrum. (September 2016)
Time-resolved detection and identification of single analyte molecules in microcapillaries by time-correlated single-photon counting (TCSPC)
Rev Sci Instrum (March 1999)
8-channel acquisition system for time-correlated single-photon counting
Rev. Sci. Instrum. (June 2013)
A study of pile-up in integrated time-correlated single photon counting systems
Rev. Sci. Instrum. (October 2013)