In this work we present a design of an external optical cavity based on Fabry-Perot etalons applied to a 100 MHz Er-doped fiber optical frequency comb working at 1560 nm to increase its repetition frequency. A Fabry-Perot cavity is constructed based on a transportable cage system with two silver mirrors in plano-concave geometry including the mode-matching lenses, fiber coupled collimation package and detection unit. The system enables full 3D angle mirror tilting and x-y off axis movement as well as distance between the mirrors. We demonstrate the increase of repetition frequency by direct measurement of the beat frequency and spectrally by using the virtually imaged phased array images.

1.
N. R.
Newbury
, “
Searching for applications with a fine-tooth comb
,”
Nat. Photonics
5
,
186
188
(
2011
).
2.
S. A.
Diddams
, “
The evolving optical frequency comb (invited)
,”
J. Opt. Soc. Am. B
27
(
11
),
B51
B62
(
2010
).
3.
M. T.
Murphy
,
T.
Udem
,
R.
Holzwarth
,
A.
Sizmann
,
L.
Pasquini
,
C.
Araujo-Hauck
,
H.
Dekker
,
S.
D’Odorico
,
M.
Fischer
,
T. W.
Hänsch
, and
A.
Manescau
, “
High-precision wavelength calibration of astronomical spectrographs with laser frequency combs
,”
Mon. Not. R. Astron. Soc.
380
,
839
847
(
2007
).
4.
A. J.
Benedick
,
G.
Chang
,
J. R.
Birge
,
L.-J.
Chen
,
A. G.
Glenday
,
C.-H.
Li
,
D. F.
Phillips
,
A.
Szentgyorgyi
,
S.
Korzennik
,
G.
Furesz
,
R. L.
Walsworth
, and
F. X.
Kärtner
, “
Visible wavelength astro-comb
,”
Opt. Express
18
(
18
),
19175
19184
(
2010
).
5.
M. J.
Thorpe
,
D.
Balslev-Clausen
,
M. S.
Kirchner
, and
J.
Ye
, “
Cavity-enhanced optical frequency spectroscopy: Application to human breath analysis
,”
Opt. Express
16
(
4
),
2387
2397
(
2008
).
6.
J.
Ye
, “
Absolute measurement of a long, arbitrary distance to less than an optical fringe
,”
Opt. Lett.
29
(
10
),
1153
1155
(
2004
).
7.
M.
Cui
,
M. G.
Zeitouny
,
N.
Bhattacharya
,
S. A.
van den Berg
,
H. P.
Urbach
, and
J. J. M.
Braat
, “
High-accuracy long-distance measurements in air with a frequency comb laser
,”
Opt. Lett.
34
(
13
),
1982
1984
(
2009
).
8.
K.
Minoshima
and
H.
Matsumoto
, “
High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser
,”
Appl. Opt.
39
(
20
),
5512
5517
(
2000
).
9.
I.
Coddington
,
W. C.
Swann
,
L.
Nenadovic
, and
N. R.
Newbury
, “
Rapid and precise absolute distance measurements at long range
,”
Nat. Photonics
3
,
351
356
(
2009
).
10.
J.
Lee
,
Y.-J.
Kim
,
K.
Lee
,
S.
Lee
, and
S.-W.
Kim
, “
Time-of-flight measurement with femtosecond light pulses
,”
Nat. Photonics
4
,
716
720
(
2010
).
11.
K.-N.
Joo
and
S.-W.
Kim
, “
Absolute distance measurement by dispersive interferometry using a femtosecond pulse laser
,”
Opt. Express
14
(
13
),
5954
5960
(
2006
).
12.
M.
Cui
,
M. G.
Zeitouny
,
N.
Bhattacharya
,
S. A.
van den Berg
, and
H. P.
Urbach
, “
Long distance measurement with femtosecond pulses using a dispersive interferometer
,”
Opt. Express
19
,
6549
6562
(
2011
).
13.
S. A.
Diddams
,
L.
Hollberg
, and
V.
Mbele
, “
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
,”
Nature
445
,
627
630
(
2007
).
14.
L.
Nugent-Glandorf
,
T.
Neely
,
F.
Adler
,
A. J.
Fleisher
,
K. C.
Cossel
,
B.
Bjork
,
T.
Dinneen
,
J.
Ye
, and
S. A.
Diddams
, “
Mid-infrared virtually imaged phased array spectrometer for rapid and broadband trace gas detection
,”
Opt. Lett.
37
(
15
),
3285
3287
(
2007
).
15.
B.
Bernhardt
,
A.
Ozawa
,
P.
Jacquet
,
M.
Jacquey
,
Y.
Kobayashi
,
T.
Udem
,
R.
Holzwarth
,
G.
Guelachvili
,
T. W.
Hänsch
, and
N.
Picqué
,
Nat. Photonics
4
,
55
57
(
2010
).
16.
J.
Mandon
,
G.
Guelachvili
, and
N.
Picqué
, “
Fourier transform spectroscopy with a laser frequency comb
,”
Nat. Photonics
3
,
99
102
(
2009
).
17.
S.
Xiao
and
A.
Weiner
, “
2D wavelength demultiplexer with potential for ≤1000 channels in the C-band
,”
Opt. Express
12
,
2895
2902
(
2004
).
18.
S. A.
van den Berg
,
S. T.
Persijn
,
G. J. P.
Kok
,
M. G.
Zeitouny
, and
N.
Bhattacharya
, “
Many-wavelength interferometry with thousands of lasers for absolute distance measurement
,”
Phys. Rev. Lett.
108
,
183901
(
2012
).
19.
H.
Jiang
,
J.
Taylor
,
F.
Quinlan
,
T.
Fortier
, and
S. A.
Diddams
, “
Noise floor reduction of an Er:fiber laser-based photonic microwave generator
,”
IEEE Photonics J.
3
,
1004
1012
(
2011
).
20.
F.
Adler
,
K.
Moutzouris
,
A.
Leitenstorfer
,
H.
Schnatz
,
B.
Lipphardt
,
G.
Grosche
, and
F.
Tauser
, “
Phase-locked two-branch erbium-doped fiber laser system for long-term precision measurements of optical frequencies
,”
Opt. Express
12
(
24
),
5872
5880
(
2004
).
21.
T.
Sizer
II
, “
Increase in laser repetition rate by spectral selection
,”
IEEE J. Quantum Electron.
25
(
1
),
97
103
(
1989
).
22.
J.
Mildner
,
K.
Meiners-Hagen
, and
F.
Pollinger
, “
Dual-frequency comb generation with differing GHz repetition rates by parallel Fabry-Perot cavity filtering of a single broadband frequency comb source
,”
Meas. Sci. Technol.
27
,
074011
(
2016
).
23.
J. R.
Lawall
, “
Fabry-Perot metrology for displacements up to 50 mm
,”
J. Opt. Soc. Am. A
22
,
2786
2798
(
2005
).
24.
G.
Bönsch
and
E.
Potulski
, “
Measurement of the refractive index of air and comparison with modified Edlén’s formulae
,”
Metrologia
35
,
133
139
(
1998
).
25.
P. E.
Ciddor
, “
Refractive index of air: New equations for the visible and near infrared
,”
Appl. Opt.
35
,
1566
1573
(
1996
).
26.
R.
Szipöcs
, “
Dispersive properties of dielectric laser mirrors and their use in femtosecond pulse lasers
,” Ph.D thesis,
SZTE TTK Szeged
, Hungary,
2000
.
27.
W. H.
Knox
,
N. M.
Pearson
,
K. D.
Li
, and
C. A.
Hirlimann
, “
Interferometric measurements of femtosecond group delay in optical components
,”
Opt. Lett.
13
(
7
),
574
576
(
1988
).
28.
M. N.
Polyanskiy
, Refractive index database, http://refractiveindex.info, (accessed 30 February 2016).
29.
A. D.
Rakić
,
A. B.
Djurišic
,
J. M.
Elazar
, and
M. L.
Majewski
, “
Optical properties of metallic films for vertical-cavity optoelectronic devices
,”
Appl. Opt.
37
,
5271
5283
(
1998
).
30.
A. V.
Tikhonravov
,
M. K.
Trubetskov
,
J.
Hrdina
, and
J.
Sobota
, “
Characterization of quasi-rugate filters using ellipsometric measurements
,”
Thin solid films
277
(
1-2
),
83
89
(
1996
).
31.
S.
Kyriacou
, “
Design and characterisation of a femtosecond enhancement cavity
,” Diploma thesis,
Imperial College London
,
2010
.
You do not currently have access to this content.