A method including the coincidence time resolution improvement for a TOF/positron emission tomography system was suggested. The spectrometer for this aim was composed of two NaI(Tl) and two plastic scintillation detectors. Experimental results were supported by FLUKA Monte Carlo simulation program by constructing the detector setup in software medium. Present experimental results verified our previous results and conclusions obtained from the suggested method. It was concluded that better resolutions would help the improvement not only on the TOF gain but also on the spatial resolution, leading to better images and helping the Physician in his/her diagnosis and treatment.
REFERENCES
1.
2.
G. F.
Knoll
, Radiation Detection and Measurements
(John Wiley & Sons Inc.
, New York
, 2000
).3.
M.
Ahmed
, B.
Camanzi
, and J.
Matheson
, Nucl. Instrum. Methods Phys. Res., Sect. A
695
, 252
(2012
).4.
W. S.
Choong
, Phys. Med. Biol.
54
, 6495
(2009
).5.
D. L.
Snyder
, L. J.
Thomas
, and M. M.
Ter-Pogossian
, IEEE Trans. Nucl. Sci.
28
, 3575
(1981
).6.
W. W.
Moses
, IEEE Trans. Nucl. Sci.
50
, 1325
(2003
).7.
K.
Shibuya
, H.
Saito
, M.
Koshimizu
, and K.
Asai
, Appl. Phys. Express
3
, 086401
(2010
).8.
M.
Conti
, Phys. Med.
25
, 1
(2009
).9.
M. E.
Casey
, http://scipp.ucsc.edu/~hartmut/UFSD/Simens_ultraHD-PET_White_Paper.pdf, accessed 15 April 2016.10.
11.
M.
Conti
, B.
Bendriem
, M.
Casey
, M.
Chen
, F.
Kehren
, C.
Michel
, and V.
Panin
, Phys. Med. Biol.
50
, 4507
(2005
).12.
J. S.
Karp
, S.
Surti
, M. E.
Daube-Witherspoon
, and G.
Muehllehner
, J. Nucl. Med.
49
, 462
(2008
).13.
L.
Friscic
, D.
Bosnar
, M.
Distler
, and M.
Makek
, https://indico.cern.ch/event/51276/contribution/237/material/paper/1.pdf, accessed 15 April 2016.14.
W. W.
Moses
, Nucl. Instrum. Methods Phys. Res., Sect. A
580
, 919
(2007
).15.
M.
Conti
, IEEE Trans. Nucl. Sci.
53
, 1188
(2006
).16.
R. L.
Harrison
, A. M.
Alessio
, P. E.
Kinahan
, and T. K.
Lewellen
, in IEEE Nuclear Science Symposium Conference Record
(IEEE
, 2004
), p. 4080
.17.
18.
A.
Ferrari
, P. R.
Sala
, A.
Fasso
, and J.
Ranft
, CERN, INFN/TC_05/11, SLAC-R-773, 2005.19.
G.
Battistoni
, F.
Cerutti
, A.
Fasso
, A.
Ferrari
, S.
Muraro
, J.
Ranft
, S.
Roesler
, and P. R.
Sala
, AIP Conf. Proc.
86
, 31
(2007
).20.
E. E.
Ermis
, C.
Celiktas
, and E.
Pilicer
, Radiat. Meas.
62
, 52
(2014
).21.
Rexon Components, Inc., NaI(Tl) Scintillation Crystal Specifications, http://www.rexon.com/NaITlBlanksSpecs.pdf, accessed 15 April 2016.
22.
Saint-Gobain plastic Scintillator, http://www.crystals.saint-gobain.com/uploadedFiles/SG-Crystals/Documents/Physcial%20Constants%20chart.pdf, accessed 15 April 2016.
23.
R. W.
Leo
, Techniques for Nuclear and Particle Physics Experiments
(Springer–Verlag
, Germany
, 1994
).24.
25.
26.
M. O.
Bedwell
and T. J.
Paulus
, IEEE Trans. Nucl. Sci.
23
, 234
(1976
).27.
J.
Vacik
, J.
Cervena
, V.
Hnatowicz
, H.
Havranek
, J.
Hoffmann
, S.
Posta
, D.
Fink
, and R.
Klett
, Nucl. Instrum. Methods Phys. Res., Sect. B
142
, 397
(1998
).28.
M.
Conti
, Nucl. Instrum. Methods Phys. Res., Sect. A
648
, S194
(2011
).29.
S.
Krishnamoorthy
, B.
Legeyt
, M. E.
Werner
, M.
Kaul
, F. M.
Newcomer
, J. S.
Karp
, and S.
Surti
, IEEE Trans. Nucl. Sci.
61
, 1092
(2014
).30.
S.
Krishnamoorthy
, R. I.
Wiener
, M.
Kaul
, J.
Panetta
, J. S.
Karp
, and S.
Surti
, IEEE Nuclear Science Symposium Conference Record
(IEEE
, 2011
), p. 2457
.31.
S.
Surti
, J. S.
Karp
, L. M.
Popescu
, M. E.
Daube-Witherspoon
, and M.
Werner
, IEEE Trans. Med. Imaging
25
, 529
(2006
).32.
M.
Conti
, Eur. J. Nucl. Med. Mol. Imaging
38
, 1147
(2011
).33.
J.
Torres
, R.
Garcia
, A.
Aguilar
, J.
Soret
, J.
Martos
, A. J.
Gonzalez
, F.
Sanchez
, J. M.
Benlloch
, and M. J.
Rodriguez
, in Implementation of TOF-PET Systems on Advanced Reconfigurable Logic Devices
, edited byS.
Misciagna
(InTech
, 2013
).34.
S.
Surti
, J. Nucl. Med.
56
, 98
(2015
).35.
S.
Surti
and J. S.
Karp
, Phys. Med.
32
, 12
(2016
).© 2016 Author(s).
2016
Author(s)
You do not currently have access to this content.