This paper describes the design of the Thomson scattering system at the Wendelstein 7-X stellarator. For the first operation campaign we installed a 10 spatial channel system to cover a radial half profile of the plasma cross section. The start-up system is based on one Nd:YAG laser with 10 Hz repetition frequency, one observation optics, five fiber bundles with one delay line each, and five interference filter polychromators with five spectral channels and silicon avalanche diodes as detectors. High dynamic range analog to digital converters with 14 bit, 1 GS/s are used to digitize the signals. The spectral calibration of the system was done using a pulsed super continuum laser together with a monochromator. For density calibration we used Raman scattering in nitrogen gas. Peaked temperature profiles and flat density profiles are observed in helium and hydrogen discharges.
Skip Nav Destination
,
,
,
,
,
,
Article navigation
November 2016
Research Article|
September 14 2016
The Thomson scattering system at Wendelstein 7-X
E. Pasch;
E. Pasch
a)
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
M. N. A. Beurskens;
M. N. A. Beurskens
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
S. A. Bozhenkov;
S. A. Bozhenkov
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
G. Fuchert;
G. Fuchert
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
J. Knauer
;
J. Knauer
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
R. C. Wolf
;
R. C. Wolf
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
Search for other works by this author on:
E. Pasch
a)
M. N. A. Beurskens
S. A. Bozhenkov
G. Fuchert
J. Knauer
R. C. Wolf
W7-X Team
Max-Planck-Institut für Plasmaphysik
, Wendelsteinstr. 1, 17491 Greifswald, Germany
a)
Author to whom correspondence should be addressed. Electronic mail: [email protected]
b)
See H. S. Bosch, Nucl. Fusion 53, 126001 (2013).
Contributed paper, published as part of the Proceedings of the 21st Topical Conference on High-Temperature Plasma Diagnostics, Madison, Wisconsin, USA, June 2016.
Rev. Sci. Instrum. 87, 11E729 (2016)
Article history
Received:
June 03 2016
Accepted:
August 16 2016
Citation
E. Pasch, M. N. A. Beurskens, S. A. Bozhenkov, G. Fuchert, J. Knauer, R. C. Wolf, W7-X Team; The Thomson scattering system at Wendelstein 7-X. Rev. Sci. Instrum. 1 November 2016; 87 (11): 11E729. https://doi.org/10.1063/1.4962248
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments
Karna A. Morey, Bryan T. Fichera, et al.
Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
P. J. Ritter, M.-A. Tucholke, et al.
Related Content
Dual-laser wavelength Thomson scattering at Wendelstein 7-X
Rev. Sci. Instrum. (October 2018)
Design and Calibration of a Polychromator for the Thomson Scattering at Wendelstein 7-X
AIP Conf. Proc. (March 2008)
Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)
Rev. Sci. Instrum. (October 2016)
Enhancing Thomson scattering polychromator performance with multi-pass spectral filters
Rev. Sci. Instrum. (September 2024)
On using Rayleigh scattering for in situ spectral calibration of Thomson scattering diagnostics
Rev. Sci. Instrum. (March 2019)