The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.
Skip Nav Destination
Article navigation
November 2016
Research Article|
August 22 2016
Understanding reconstructed Dante spectra using high resolution spectroscopy
M. J. May;
M. J. May
a)
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
J. Weaver
;
J. Weaver
2
Naval Research Laboratory
, 4555 Overlook Ave. SW, Washington, DC 20375, USA
Search for other works by this author on:
K. Widmann
;
K. Widmann
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
G. E. Kemp;
G. E. Kemp
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
D. Thorn;
D. Thorn
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
J. D. Colvin
;
J. D. Colvin
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
M. B. Schneider
;
M. B. Schneider
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
A. Moore;
A. Moore
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
B. E. Blue
B. E. Blue
1
L-170 Lawrence Livermore National Laboratory
, 7000 East Ave., Livermore, California 94551, USA
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Electronic mail: [email protected]
Contributed paper, published as part of the Proceedings of the 21st Topical Conference on High-Temperature Plasma Diagnostics, Madison, Wisconsin, USA, June 2016.
Rev. Sci. Instrum. 87, 11E330 (2016)
Article history
Received:
June 04 2016
Accepted:
July 26 2016
Citation
M. J. May, J. Weaver, K. Widmann, G. E. Kemp, D. Thorn, J. D. Colvin, M. B. Schneider, A. Moore, B. E. Blue; Understanding reconstructed Dante spectra using high resolution spectroscopy. Rev. Sci. Instrum. 1 November 2016; 87 (11): 11E330. https://doi.org/10.1063/1.4961267
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Implementation of simultaneous ultraviolet/visible and x-ray absorption spectroscopy with microfluidics
Olivia McCubbin Stepanic, Christopher J. Pollock, et al.
Related Content
Uncertainty analysis technique for OMEGA Dante measurements
Rev. Sci. Instrum. (October 2010)
Source geometric considerations for OMEGA Dante measurements
Rev. Sci. Instrum. (July 2012)
Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments
Rev. Sci. Instrum. (March 2021)
NIF unconverted light and its influence on DANTE measurements
Rev. Sci. Instrum. (June 2009)
Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility
Phys. Plasmas (June 2017)