Non-contact imaging techniques are preferred in ophthalmology. Corneal disease is one of the leading causes of blindness worldwide, and a possible way of detection is by analyzing the shape and optical quality of the cornea. Here, a simple and cost-effective, non-contact optical probe system is proposed and illustrated. The probe possesses high spatial resolutions and is non-dependent on coupling medium, which are significant for a clinician and patient friendly investigation. These parameters are crucial, when considering an imaging system for the objective diagnosis and management of corneal diseases. The imaging of the cornea is performed on ex vivo porcine samples and subsequently on small laboratory animals, in vivo. The clinical significance of the proposed study is validated by performing imaging of the New Zealand white rabbit’s cornea infected with Pseudomonas.
Skip Nav Destination
Article navigation
September 2015
Research Article|
September 10 2015
A simple and non-contact optical imaging probe for evaluation of corneal diseases
Xun Jie Jeesmond Hong;
Xun Jie Jeesmond Hong
1Center for Optical and Laser Engineering, School of MAE,
Nanyang Technological University
, Singapore 639798
Search for other works by this author on:
V. K. Shinoj
;
V. K. Shinoj
1Center for Optical and Laser Engineering, School of MAE,
Nanyang Technological University
, Singapore 639798
Search for other works by this author on:
V. M. Murukeshan;
V. M. Murukeshan
a)
1Center for Optical and Laser Engineering, School of MAE,
Nanyang Technological University
, Singapore 639798
Search for other works by this author on:
M. Baskaran
;
M. Baskaran
2
Singapore Eye Research Institute (SERI) and Singapore National Eye Center (SNEC)
, 11 Third Hospital Avenue, Singapore 168751
Search for other works by this author on:
T. Aung
T. Aung
2
Singapore Eye Research Institute (SERI) and Singapore National Eye Center (SNEC)
, 11 Third Hospital Avenue, Singapore 168751
Search for other works by this author on:
a)
Electronic mail: mmurukeshan@ntu.edu.sg
Rev. Sci. Instrum. 86, 093702 (2015)
Article history
Received:
April 23 2015
Accepted:
August 17 2015
Citation
Xun Jie Jeesmond Hong, V. K. Shinoj, V. M. Murukeshan, M. Baskaran, T. Aung; A simple and non-contact optical imaging probe for evaluation of corneal diseases. Rev. Sci. Instrum. 1 September 2015; 86 (9): 093702. https://doi.org/10.1063/1.4929684
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
High-resolution corneal topography and tomography of fish eye using wide-field white light interference microscopy
Appl. Phys. Lett. (April 2013)
Assessing the phase retardation in corneal tissues using a femtosecond laser
Rev. Sci. Instrum. (August 2013)
Evaluation of corneal and eye lens irradiance for optical aided viewing
Journal of Laser Applications (March 2013)
Simultaneously imaging and quantifying in vivo mechanical properties of crystalline lens and cornea using optical coherence elastography with acoustic radiation force excitation
APL Photonics (October 2019)
Scanning laser system to determine the corneal shape
Rev. Sci. Instrum. (June 2005)