The real part of the refractive index is measured from 1.30 to above 3.00 without the use of index matching fluids. This approach expands upon the Brewster angle technique as both S and P polarized lights are used and the full Fresnel equations fitted to the data to extract the index of refraction using nonlinear curve fitting.
REFERENCES
1.
See http://www.cargille.com/refractivestandards.shtml for available index matching fluids.
2.
J. G.
Beckerley
, E. B.
Meservey
, and B. A.
Wooten
Jr., Am. J. Phys.
13
, 116
(1945
).3.
C. S.
Hurlbut
and M.
Hyman
Jr., U.S. Patent 5,572,315 (Nov 5, 1996
).4.
C.
Bahrim
and W.
Hsu
, Am. J. Phys.
77
, 337
(2009
).5.
P. J.
Ouseph
, K.
Driver
, and J.
Conklin
, Am. J. Phys.
69
, 1166
(2001
).6.
J. A.
Vose
, J. P.
McClymer
, and T. W.
Trip
, U.S. Patent 7,903,243 (Mar 8, 2011
).7.
See, for example,
F. L.
Pedrotti
, L. M.
Pedrotti
, and L. S.
Pedrotti
, Introduction to Optics
, 3rd ed. (Pearson Prentice Hall
, 2007
).8.
See, for example,
M.
Born
and E.
Wolf
, Principles of Optics
(Pergamon Press
, 1980
), or similar optics or electromagnetism text.9.
See http://www.crystran.co.uk/userfiles/files/yttrium-aluminium-garnet-yag-data-sheet.pdf for index of refraction data.
10.
See http://refractiveindex.info/?group=CRYSTALS&material=Y3Al5O12 for index of refraction data.
© 2014 AIP Publishing LLC.
2014
AIP Publishing LLC
You do not currently have access to this content.