The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: 54Fe, 10+ state (E = 6527.1 (11) keV, T1/2 = 364(7) ns) and the 5/2+ state of 19F (E = 197.143 (4) keV, T1/2 = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10+ state was T1/2 = 365(14) ns and for the 5/2+ state, 100(36) ns.
Skip Nav Destination
,
,
,
,
,
,
,
,
Article navigation
July 2014
Research Article|
July 14 2014
A system to measure isomeric state half-lives in the 10 ns to 10 μs range
D. L. Toufen;
D. L. Toufen
a)
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
2
Federal Institute of Education
, Science and Technology of São Paulo - IFSP, 07115-000 Guarulhos, São Paulo, Brazil
Search for other works by this author on:
P. R. P. Allegro;
P. R. P. Allegro
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
N. H. Medina;
N. H. Medina
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
J. R. B. Oliveira;
J. R. B. Oliveira
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
E. W. Cybulska;
E. W. Cybulska
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
W. A. Seale;
W. A. Seale
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
R. Linares;
R. Linares
3
Fluminense Federal University
, 24220-900 Niterói, Rio de Janeiro, Brazil
Search for other works by this author on:
M. A. G. Silveira;
M. A. G. Silveira
4
Universitary Center of FEI
, 09850-901 São Bernardo do Campo, São Paulo, Brazil
Search for other works by this author on:
R. V. Ribas
R. V. Ribas
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
Search for other works by this author on:
D. L. Toufen
1,2,a)
P. R. P. Allegro
1
N. H. Medina
1
J. R. B. Oliveira
1
E. W. Cybulska
1
W. A. Seale
1
R. Linares
3
M. A. G. Silveira
4
R. V. Ribas
1
1Institute of Physics,
University of São Paulo
, C.P. 66318, 05315-970 São Paulo, São Paulo, Brazil
2
Federal Institute of Education
, Science and Technology of São Paulo - IFSP, 07115-000 Guarulhos, São Paulo, Brazil
3
Fluminense Federal University
, 24220-900 Niterói, Rio de Janeiro, Brazil
4
Universitary Center of FEI
, 09850-901 São Bernardo do Campo, São Paulo, Brazil
Rev. Sci. Instrum. 85, 073501 (2014)
Article history
Received:
February 04 2014
Accepted:
June 23 2014
Citation
D. L. Toufen, P. R. P. Allegro, N. H. Medina, J. R. B. Oliveira, E. W. Cybulska, W. A. Seale, R. Linares, M. A. G. Silveira, R. V. Ribas; A system to measure isomeric state half-lives in the 10 ns to 10 μs range. Rev. Sci. Instrum. 1 July 2014; 85 (7): 073501. https://doi.org/10.1063/1.4886814
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments
Karna A. Morey, Bryan T. Fichera, et al.
Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
P. J. Ritter, M.-A. Tucholke, et al.
Related Content
A novel YAG:Ce/CsI:Tl phoswich detector consisting of transparent ceramic scintillator for α–γ discrimination
AIP Advances (January 2023)
Design optimization of a truncated cone-shaped LaBr3:Ce/NaI:Tl phoswich detector based on GEANT4 simulation
AIP Advances (January 2023)
Phoswich scintillator for proton and gamma radiation of high energy
AIP Conf. Proc. (November 2011)
Fast phoswich scintillator endcap for gamma and proton detection
AIP Conf. Proc. (June 2013)
A High Resolution Phoswich Detector: LaBr 3 ( Ce ) Coupled With LaCl 3 ( Ce )
AIP Conf. Proc. (April 2010)