The double threshold method realized by hardware circuits and high performance timing chip TDC-GP21 was successfully adapted to solve the key problem of ultrasonic distance measurement, the accurate time-of-flight (TOF) measurement of ultrasonic wave. Compared with other techniques of TOF measurement, the double threshold method presented in this work can suppress noise in the received signal, and achieve a time resolution of around 22 ps and real-time. This method is easy to realize and pertains the advantage of low cost. To compensate temperature and pressure deviations, a temperature measurement module of 10 mK in precision as well as a pressure measurement module of 0.01% in accuracy was developed. The system designed in this work can be exactly used as a two paths ultrasonic gas flowmeter without any adjustment of the hardware circuit. The double threshold method was further corroborated using experiment results of both the ultrasonic distance measurement and ultrasonic gas flow measurement. In distance measurement, the maximum absolute deviation and the maximum relative error are 0.69 mm and 0.28%, respectively, for a target distance range of 100–600 mm. In flow measurement, the maximum absolute deviation and the worst repeatability are 1.16% and 0.65% for a flow in the range of 50–700 m3/h.
Skip Nav Destination
Article navigation
April 2014
Research Article|
April 28 2014
Double threshold ultrasonic distance measurement technique and its application
Weihua Li;
Weihua Li
Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education,
Xi'an Jiaotong University
, Xi'an, Shaanxi 710049, China
Search for other works by this author on:
Qiang Chen;
Qiang Chen
Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education,
Xi'an Jiaotong University
, Xi'an, Shaanxi 710049, China
Search for other works by this author on:
Jiangtao Wu
Jiangtao Wu
a)
Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education,
Xi'an Jiaotong University
, Xi'an, Shaanxi 710049, China
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Electronic mail: jtwu@mail.xjtu.edu.cn
Rev. Sci. Instrum. 85, 044905 (2014)
Article history
Received:
October 12 2013
Accepted:
April 09 2014
Citation
Weihua Li, Qiang Chen, Jiangtao Wu; Double threshold ultrasonic distance measurement technique and its application. Rev. Sci. Instrum. 1 April 2014; 85 (4): 044905. https://doi.org/10.1063/1.4871993
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
An absolute instrument for determination of the speed of sound in water
Rev. Sci. Instrum. (May 2016)
Note: Ultrasonic liquid flow meter for small pipes
Rev. Sci. Instrum. (February 2012)
Generalized invariants for the time‐dependent harmonic oscillator
J. Math. Phys. (August 2008)
Hyper‐Rayleigh scattering in solution
Rev Sci Instrum (June 1992)
Assembly and infection process of bacteriophage T4
Chaos (December 2005)