The ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK uses a Penning surface plasma negative hydrogen ion source. Upgrade options for the ISIS accelerator system demand a higher current, lower emittance beam with longer pulse lengths from the injector. The Front End Test Stand is being constructed at RAL to meet the upgrade requirements using a modified ISIS ion source. A new 10% duty cycle 25 kV pulsed extraction power supply has been commissioned and the first meter of 3 MeV radio frequency quadrupole has been delivered. Simultaneously, a Vessel for Extraction and Source Plasma Analyses is under construction in a new laboratory at RAL. The detailed measurements of the plasma and extracted beam characteristics will allow a radical overhaul of the transport optics, potentially yielding a simpler source configuration with greater output and lifetime.
Skip Nav Destination
Article navigation
February 2014
14th International Conference on Ion Sources (ICIS 2011)
12-16 September 2011
Giardini-Naxos, Sicily (Italy)
Research Article|
January 07 2014
Development of the front end test stand and vessel for extraction and source plasma analyses negative hydrogen ion sources at the Rutherford Appleton Laboratorya)
S. R. Lawrie;
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
2John Adams Institute of Accelerator Science,
University of Oxford
, Oxford, United Kingdom
Search for other works by this author on:
D. C. Faircloth;
D. C. Faircloth
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
A. P. Letchford;
A. P. Letchford
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
M. Perkins;
M. Perkins
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
M. O. Whitehead;
M. O. Whitehead
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
T. Wood;
T. Wood
1STFC ISIS Pulsed Spallation Neutron and Muon Facility,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
C. Gabor;
C. Gabor
3ASTeC Intense Beams Group,
Rutherford Appleton Laboratory
, Harwell Oxford, Harwell, United Kingdom
Search for other works by this author on:
J. Back
J. Back
4High Energy Physics Department,
University of Warwick
, Coventry, United Kingdom
Search for other works by this author on:
b)
Author to whom correspondence should be addressed. Electronic mail: [email protected].
a)
Contributed paper, published as part of the Proceedings of the 15th International Conference on Ion Sources, Chiba, Japan, September 2013.
Rev. Sci. Instrum. 85, 02B127 (2014)
Article history
Received:
September 09 2013
Accepted:
September 26 2013
Citation
S. R. Lawrie, D. C. Faircloth, A. P. Letchford, M. Perkins, M. O. Whitehead, T. Wood, C. Gabor, J. Back; Development of the front end test stand and vessel for extraction and source plasma analyses negative hydrogen ion sources at the Rutherford Appleton Laboratory. Rev. Sci. Instrum. 1 February 2014; 85 (2): 02B127. https://doi.org/10.1063/1.4826109
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
Related Content
First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)
AIP Conference Proceedings (April 2015)
Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H− ion source
Rev. Sci. Instrum. (October 2015)
Recent H− diagnostics, plasma simulations, and 2X scaled Penning ion source developments at the Rutherford Appleton Laboratory
Rev. Sci. Instrum. (April 2018)
Matching an H– beam into a radio frequency quadrupole at Rutherford Appleton Laboratory
Rev. Sci. Instrum. (February 2014)
H– beam transport experiments in a solenoid low energy beam transport
Rev. Sci. Instrum. (February 2012)