A novel sample mount design with integrated fiducial marks and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mount methodology allows data to be efficiently and easily collected on different instruments for the same sample location.
Skip Nav Destination
Article navigation
February 2014
Research Article|
February 03 2014
Integrated fiducial sample mount and software for correlated microscopy
Timothy R. McJunkin;
Timothy R. McJunkin
Idaho National Laboratory
, Idaho Falls, Idaho 83415, USA
Search for other works by this author on:
Tammy L. Trowbridge;
Tammy L. Trowbridge
Idaho National Laboratory
, Idaho Falls, Idaho 83415, USA
Search for other works by this author on:
Karen E. Wright;
Karen E. Wright
Idaho National Laboratory
, Idaho Falls, Idaho 83415, USA
Search for other works by this author on:
Jill R. Scott
Jill R. Scott
a)
Idaho National Laboratory
, Idaho Falls, Idaho 83415, USA
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Electronic mail: jill.scott@inl.gov.
Rev. Sci. Instrum. 85, 023701 (2014)
Article history
Received:
September 13 2013
Accepted:
January 07 2014
Citation
Timothy R. McJunkin, Tammy L. Trowbridge, Karen E. Wright, Jill R. Scott; Integrated fiducial sample mount and software for correlated microscopy. Rev. Sci. Instrum. 1 February 2014; 85 (2): 023701. https://doi.org/10.1063/1.4862935
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
Related Content
Accurate measurement of relative tilt and azimuth angles in electron tomography: A comparison of fiducial marker method with electron diffraction
Rev. Sci. Instrum. (August 2014)
Improving manganin gauge measurements near radiographic fiducials
AIP Conf. Proc. (September 2023)
A method to track rotational motion for use in single-molecule biophysics
Rev. Sci. Instrum. (October 2011)
Quantum localisation on the circle
J. Math. Phys. (May 2018)