We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.
Skip Nav Destination
Article navigation
August 2013
Research Article|
August 02 2013
Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope
Pavel Hanzelka;
Pavel Hanzelka
a)
1Institute of Scientific Instruments of the ASCR, v.v.i.,
Academy of Sciences of the Czech Republic
, Kralovopolska 147, 612 64 Brno, Czech Republic
Search for other works by this author on:
Jakub Vonka;
Jakub Vonka
2Institute of Physical Engineering,
Brno University of Technology
, Technicka 2, 616 69 Brno, Czech Republic
Search for other works by this author on:
Vera Musilova
Vera Musilova
1Institute of Scientific Instruments of the ASCR, v.v.i.,
Academy of Sciences of the Czech Republic
, Kralovopolska 147, 612 64 Brno, Czech Republic
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Electronic mail: hanzelka@isibrno.cz
Rev. Sci. Instrum. 84, 085103 (2013)
Article history
Received:
March 07 2013
Accepted:
July 17 2013
Citation
Pavel Hanzelka, Jakub Vonka, Vera Musilova; Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope. Rev. Sci. Instrum. 1 August 2013; 84 (8): 085103. https://doi.org/10.1063/1.4817214
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
Citing articles via
Subharmonic lock-in detection and its optimization for femtosecond noise correlation spectroscopy
M. A. Weiss, F. S. Herbst, et al.
Learning from each other: Cross-cutting diagnostic development activities between magnetic and inertial confinement fusion (invited)
M. Gatu Johnson, D. Schlossberg, et al.
Related Content
A 350 mK, 9 T scanning tunneling microscope for the study of superconducting thin films on insulating substrates and single crystals
Rev. Sci. Instrum. (December 2013)
An ultrahigh vacuum fast-scanning and variable temperature scanning tunneling microscope for large scale imaging
Rev. Sci. Instrum. (October 2007)
Electrical conductivity measurements on disk-shaped samples
Rev. Sci. Instrum. (July 2014)
In situ manipulation of scanning tunneling microscope tips without tip holder
Rev. Sci. Instrum. (January 2010)
Low cost cryogenic high vacuum sample holder for in-plane magneto-transport studies
J. Vac. Sci. Technol. B (July 2012)