A simple, single-channel millimeter-wave interferometer system has been designed, fabricated, and installed on the J-TEXT tokamak. For the plasma density anticipated on J-TEXT, a solid-state source operating at 150 GHz has been chosen to minimize errors due to both vibration along the beam path and refraction in the plasma. The new aspect of the interferometer design is to use a subharmonic mixer for detection with a frequency doubled 150 GHz source. It employs a single source which is bias-tuned and modulated with a sawtooth wave form up to 100 kHz in order to generate the intermediate frequency. The 12.5 GHz voltage-controlled oscillator is multiplied to 75 GHz before a final doubler raises it to 150 GHz. A portion of the 75 GHZ power is used for the local oscillator (LO) and is directly connected to the LO input of the subharmonic mixer. The phase is evaluated by a digital phase comparator using a software-based algorithm. Detection noise limits the minimum resolvable phase change with the interferometer to ±0.05 fringe, which corresponds to an averaged electron density change along the chord of ±1.1 × 1017 m−2. The maximum measurable electron density is expected to be ∼9 × 1019 m−3. A comparison of preliminary results from the millimeter wave interferometer with that from the far-infrared hydrogen cyanide laser (wavelength of 337 μm) interferometer shows good agreement during the pulse flat-top period. The millimeter wave interferometer system will be used as a part of the density feedback control system in the future.
Skip Nav Destination
Article navigation
April 2013
Research Article|
April 29 2013
Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak Available to Purchase
X. D. Feng;
X. D. Feng
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Search for other works by this author on:
G. Zhuang;
G. Zhuang
a)
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Search for other works by this author on:
Z. J. Yang;
Z. J. Yang
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Search for other works by this author on:
L. Gao;
L. Gao
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Search for other works by this author on:
X. W. Hu
X. W. Hu
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Search for other works by this author on:
X. D. Feng
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
G. Zhuang
a)
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
Z. J. Yang
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
L. Gao
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
X. W. Hu
State Key Laboratory of Advanced Electromagnetic Engineering and Technology,
Huazhong University of Science and Technology
, Wuhan 430074, China
a)
Author to whom correspondence should be addressed. Electronic mail: [email protected]
Rev. Sci. Instrum. 84, 044705 (2013)
Article history
Received:
January 07 2013
Accepted:
April 08 2013
Citation
X. D. Feng, G. Zhuang, Z. J. Yang, L. Gao, X. W. Hu; Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak. Rev. Sci. Instrum. 1 April 2013; 84 (4): 044705. https://doi.org/10.1063/1.4802690
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Related Content
Density modulation experiment to determine transport coefficients on Joint-TEXT Tokamak
Rev. Sci. Instrum. (February 2015)
Recent progress of the HCN interferometer on J-TEXT tokamak
Rev. Sci. Instrum. (June 2012)
First results from the J-TEXT high-resolution three-wave polarimeter-interferometer
Rev. Sci. Instrum. (June 2012)
Vibration mitigation in J-TEXT far-infrared diagnostic systems
Rev. Sci. Instrum. (July 2012)
Multichannel millimeter wave interferometer for W7-AS
Rev. Sci. Instrum. (February 1997)