Angular correlation of annihilation radiation (ACAR) is a well established technique for the investigation of the electronic structure. A major limitation of ACAR studies is the available positron flux at a small spot on the sample. For this reason, the focus of this work is put on the discussion of a newly developed source-sample stage of the new 2D-ACAR spectrometer at Technische Universität München which uses an optimized static magnetic field configuration to guide the positrons onto the sample. The achieved spot diameter is dFWHM = 5.4 mm, with a high efficiency over the whole energy spectrum of the 22Na positron source. The implications of the performance of the source-sample stage are discussed with regard to 2D-ACAR measurements of single crystalline α-quartz, which serves as a model system for the determination of the total resolution. A value of (1.53 × 1.64) mrad2 FWHM was achieved at room temperature.
Skip Nav Destination
Article navigation
April 2013
Research Article|
April 18 2013
The source-sample stage of the new two-dimensional angular correlation of annihilation radiation spectrometer at Technische Universität München
Hubert Ceeh;
Hubert Ceeh
a)
1
Technische Universität München
, Lehrstuhl E21, James-Franck Straße, 85747 Garching, Germany
Search for other works by this author on:
Josef Andreas Weber;
Josef Andreas Weber
1
Technische Universität München
, Lehrstuhl E21, James-Franck Straße, 85747 Garching, Germany
Search for other works by this author on:
Michael Leitner;
Michael Leitner
2FRM II,
Technische Universität München
, Lichtenbergstraße 1, 85747 Garching, Germany
Search for other works by this author on:
Peter Böni;
Peter Böni
1
Technische Universität München
, Lehrstuhl E21, James-Franck Straße, 85747 Garching, Germany
Search for other works by this author on:
Christoph Hugenschmidt
Christoph Hugenschmidt
1
Technische Universität München
, Lehrstuhl E21, James-Franck Straße, 85747 Garching, Germany
2FRM II,
Technische Universität München
, Lichtenbergstraße 1, 85747 Garching, Germany
Search for other works by this author on:
a)
Electronic mail: [email protected]
Rev. Sci. Instrum. 84, 043905 (2013)
Article history
Received:
October 15 2012
Accepted:
March 25 2013
Citation
Hubert Ceeh, Josef Andreas Weber, Michael Leitner, Peter Böni, Christoph Hugenschmidt; The source-sample stage of the new two-dimensional angular correlation of annihilation radiation spectrometer at Technische Universität München. Rev. Sci. Instrum. 1 April 2013; 84 (4): 043905. https://doi.org/10.1063/1.4801454
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
Study on the Enhanced Contribution in Noble Metals from Positron Annihilation
AIP Conference Proceedings (February 2007)
Recent developments of the scanning positron microscope SPM for depth- and position-resolved positron lifetime measurement
AIP Conf. Proc. (December 2019)
Reaction of positronium with doped ions in silica-based glasses in the size determination of subnanometer structural open spaces
J. Appl. Phys. (October 2013)
Fermiology via the electron momentum distribution (Review Article)
Low Temp. Phys. (August 2009)
Annihilation characteristics for positrons trapped at the surfaces of simple metals
AIP Conference Proceedings (June 1994)