A novel, compact-sized (19 cm × 16 cm) and portable (500 g) magnetic resonance relaxometry system is designed and developed. We overcame several key engineering barriers so that magnetic resonance technology can be potentially used for disease diagnosis-monitoring in point-of-care settings, directly on biological cells and tissues. The whole system consists of a coin-sized permanent magnet (0.76 T), miniaturized radio-frequency microcoil probe, compact lumped-circuit duplexer, and single board 1-W power amplifier, in which a field programmable gate array -based spectrometer is used for pulse excitation, signal acquisition, and data processing. We show that by measuring the proton transverse relaxation rates from a large pool of natural abundance proton-nuclei presence in less than 1 μL of red blood cells, one can indirectly deduce the relative magnetic susceptibility of the bulk cells within a few minutes of signal acquisition time. Such rapid and sensitive blood screening system can be used to monitor the fluctuation of the bulk magnetic susceptibility of the biological cells (e.g., human blood cells), where unusual state of the bulk magnetic susceptibility is related to a number of diseases.
Skip Nav Destination
Article navigation
September 2012
Research Article|
September 26 2012
Development of miniaturized, portable magnetic resonance relaxometry system for point-of-care medical diagnosis
Weng Kung Peng;
Weng Kung Peng
1BioSystems and Micromechanics IRG (BioSyM),
Singapore - Massachusetts Institute of Technology Alliance for Research and Technology (SMART) Centre
, S16-05-08, 3 Science Drive 2, Singapore 117543
Search for other works by this author on:
Lan Chen;
Lan Chen
1BioSystems and Micromechanics IRG (BioSyM),
Singapore - Massachusetts Institute of Technology Alliance for Research and Technology (SMART) Centre
, S16-05-08, 3 Science Drive 2, Singapore 117543
Search for other works by this author on:
Jongyoon Han
Jongyoon Han
1BioSystems and Micromechanics IRG (BioSyM),
Singapore - Massachusetts Institute of Technology Alliance for Research and Technology (SMART) Centre
, S16-05-08, 3 Science Drive 2, Singapore 1175432Department of Electrical Engineering and Computer Science,
Massachusetts Institute of Technology
, 36-841, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA and Department of Biological Engineering, Massachusetts Institute of Technology
, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA
Search for other works by this author on:
Rev. Sci. Instrum. 83, 095115 (2012)
Article history
Received:
April 09 2012
Accepted:
September 05 2012
Citation
Weng Kung Peng, Lan Chen, Jongyoon Han; Development of miniaturized, portable magnetic resonance relaxometry system for point-of-care medical diagnosis. Rev. Sci. Instrum. 1 September 2012; 83 (9): 095115. https://doi.org/10.1063/1.4754296
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
Citing articles via
Subharmonic lock-in detection and its optimization for femtosecond noise correlation spectroscopy
M. A. Weiss, F. S. Herbst, et al.
Related Content
Plastering mortar with antibacterial and antifungal properties studied by 1H NMR relaxometry
AIP Conference Proceedings (December 2017)
Dynamics of solid alanine by means of nuclear magnetic resonance relaxometry
J. Chem. Phys. (April 2017)
Interaction effects enhancing magnetic particle detection based on magneto-relaxometry
Appl. Phys. Lett. (January 2015)
1H NMR relaxometry and quadrupole relaxation enhancement as a sensitive probe of dynamical properties of solids—[C(NH2)3]3Bi2I9 as an example
J. Chem. Phys. (February 2016)
Dynamical properties of solid and hydrated collagen: Insight from nuclear magnetic resonance relaxometry
J. Chem. Phys. (April 2024)