We describe a liquid jet injector system developed to deliver fully solvated microscopic target species into a probe beam under either vacuum or ambient conditions. The injector was designed specifically for x-ray scattering studies of biological nanospecies using x-ray free electron lasers and third generation synchrotrons, but is of interest to any application in which microscopic samples must be delivered in a fully solvated state and with microscopic precision. By utilizing a gas dynamic virtual nozzle (GDVN) to generate a sample-containing liquid jet of diameter ranging from 300 nm to 20 μm, the injector avoids the clogging problems associated in this size range with conventional Rayleigh jets. A differential pumping system incorporated into the injector shields the experimental chamber from the gas load of the GDVN, making the injector compatible with high vacuum systems. The injector houses a fiber-optically coupled pump laser to illuminate the jet for pump-probe experiments and a hermetically sealed microscope to observe the liquid jet for diagnostics and alignment during operation. This injector system has now been used during several experimental runs at the Linac Coherent Light Source. Recent refinements in GDVN design are also presented.
Skip Nav Destination
Article navigation
March 2012
Research Article|
March 21 2012
Injector for scattering measurements on fully solvated biospecies
U. Weierstall;
U. Weierstall
Department of Physics,
Arizona State University
, Tempe, Arizona 85287-1504, USA
Search for other works by this author on:
J. C. H. Spence;
J. C. H. Spence
Department of Physics,
Arizona State University
, Tempe, Arizona 85287-1504, USA
Search for other works by this author on:
R. B. Doak
R. B. Doak
Department of Physics,
Arizona State University
, Tempe, Arizona 85287-1504, USA
Search for other works by this author on:
Rev. Sci. Instrum. 83, 035108 (2012)
Article history
Received:
November 11 2011
Accepted:
February 20 2012
Citation
U. Weierstall, J. C. H. Spence, R. B. Doak; Injector for scattering measurements on fully solvated biospecies. Rev. Sci. Instrum. 1 March 2012; 83 (3): 035108. https://doi.org/10.1063/1.3693040
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Analysis methodology of coherent oscillations in time- and angle-resolved photoemission spectroscopy
Nicolas Gauthier, Hadas Soifer, et al.
Related Content
Microfluidic polyimide gas dynamic virtual nozzles for serial crystallography
Rev. Sci. Instrum. (August 2020)
Microscopic linear liquid streams in vacuum: Injection of solvated biological samples into X-ray free electron lasers
AIP Conference Proceedings (November 2012)
Kilohertz droplet-on-demand serial femtosecond crystallography at the European XFEL station FXE
Struct. Dyn. (April 2024)
A liquid jet setup for x-ray scattering experiments on complex liquids at free-electron laser sources
Rev. Sci. Instrum. (June 2016)
The serial millisecond crystallography instrument at the Australian Synchrotron incorporating the “Lipidico” injector
Rev. Sci. Instrum. (August 2019)