A thrust stand calibration technique for use in testing repetitively pulsed electric thrusters for in-space propulsion has been developed and tested using a modified hanging pendulum thrust stand. In the implementation of this technique, current pulses are applied to a solenoid to produce a pulsed magnetic field that acts against a permanent magnet mounted to the thrust stand pendulum arm. The force on the magnet is applied in this non-contact manner, with the entire pulsed force transferred to the pendulum arm through a piezoelectric force transducer to provide a time-accurate force measurement. Modeling of the pendulum arm dynamics reveals that after an initial transient in thrust stand motion the quasi-steady average deflection of the thrust stand arm away from the unforced or “zero” position can be related to the average applied force through a simple linear Hooke's law relationship. Modeling demonstrates that this technique is universally applicable except when the pulsing period is increased to the point where it approaches the period of natural thrust stand motion. Calibration data were obtained using a modified hanging pendulum thrust stand previously used for steady-state thrust measurements. Data were obtained for varying impulse bit at constant pulse frequency and for varying pulse frequency. The two data sets exhibit excellent quantitative agreement with each other. The overall error on the linear regression fit used to determine the calibration coefficient was roughly 1%.
Skip Nav Destination
,
,
,
Article navigation
February 2012
Research Article|
February 07 2012
Non-contact thrust stand calibration method for repetitively pulsed electric thrusters
Andrea R. Wong;
Andrea R. Wong
NASA-Marshall Space Flight Center
, Huntsville, Alabama 35812, USA
Search for other works by this author on:
Alexandra Toftul;
Alexandra Toftul
NASA-Marshall Space Flight Center
, Huntsville, Alabama 35812, USA
Search for other works by this author on:
Kurt A. Polzin;
Kurt A. Polzin
a)
NASA-Marshall Space Flight Center
, Huntsville, Alabama 35812, USA
Search for other works by this author on:
J. Boise Pearson
J. Boise Pearson
NASA-Marshall Space Flight Center
, Huntsville, Alabama 35812, USA
Search for other works by this author on:
Andrea R. Wong
Alexandra Toftul
Kurt A. Polzin
a)
J. Boise Pearson
NASA-Marshall Space Flight Center
, Huntsville, Alabama 35812, USA
a)
Electronic mail: [email protected].
Rev. Sci. Instrum. 83, 025103 (2012)
Article history
Received:
September 02 2011
Accepted:
January 05 2012
Citation
Andrea R. Wong, Alexandra Toftul, Kurt A. Polzin, J. Boise Pearson; Non-contact thrust stand calibration method for repetitively pulsed electric thrusters. Rev. Sci. Instrum. 1 February 2012; 83 (2): 025103. https://doi.org/10.1063/1.3680557
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Long-range spin wave imaging with nitrogen vacancy centers and time resolved magneto-optical measurements
Carolina Lüthi, Lukas Colombo, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
Thrust stand for electric propulsion performance evaluation
Rev. Sci. Instrum. (October 2006)
Thrust stand for vertically oriented electric propulsion performance evaluation
Rev. Sci. Instrum. (November 2010)
Validation of a torsional balance for thrust measurements of Hall effect and microwave-based space propulsion systems
Rev. Sci. Instrum. (November 2022)
A method for evaluating the thrust of a space propulsion device with wide range time variations using a disturbance observer
Rev. Sci. Instrum. (November 2015)
Development of inverted pendulum thrust stand with spring-shaped wire for high power electric thrusters
Rev. Sci. Instrum. (March 2023)