The construction of a microscope with fast sample transfer system for single-molecule spectroscopy and microscopy at low temperatures using 2D/3D sample-scanning is reported. The presented construction enables the insertion of a sample from the outside (room temperature) into the cooled (4.2 K) cryostat within seconds. We describe the mechanical and optical design and present data from individual Photosystem I complexes. With the described setup numerous samples can be investigated within one cooling cycle. It opens the possibility to investigate biological samples (i) without artifacts introduced by prolonged cooling procedures and (ii) samples that require preparation steps like plunge-freezing or specific illumination procedures prior to the insertion into the cryostat.
Skip Nav Destination
,
,
Article navigation
December 2012
Research Article|
December 12 2012
Confocal sample-scanning microscope for single-molecule spectroscopy and microscopy with fast sample exchange at cryogenic temperatures Available to Purchase
Martin Hussels;
Martin Hussels
Universität Tübingen
, Institut für Physikalische und Theoretische Chemie and LISA+ Center, Auf der Morgenstelle 18, 72076 Tübingen, Germany
Search for other works by this author on:
Alexander Konrad;
Alexander Konrad
Universität Tübingen
, Institut für Physikalische und Theoretische Chemie and LISA+ Center, Auf der Morgenstelle 18, 72076 Tübingen, Germany
Search for other works by this author on:
Marc Brecht
Marc Brecht
a)
Universität Tübingen
, Institut für Physikalische und Theoretische Chemie and LISA+ Center, Auf der Morgenstelle 18, 72076 Tübingen, Germany
Search for other works by this author on:
Martin Hussels
Alexander Konrad
Marc Brecht
a)
Universität Tübingen
, Institut für Physikalische und Theoretische Chemie and LISA+ Center, Auf der Morgenstelle 18, 72076 Tübingen, Germany
a)
Telephone: +49-7071-29-76239. Fax: +49-7071-29-5490. E-mail: [email protected].
Rev. Sci. Instrum. 83, 123706 (2012)
Article history
Received:
June 28 2012
Accepted:
November 19 2012
Citation
Martin Hussels, Alexander Konrad, Marc Brecht; Confocal sample-scanning microscope for single-molecule spectroscopy and microscopy with fast sample exchange at cryogenic temperatures. Rev. Sci. Instrum. 1 December 2012; 83 (12): 123706. https://doi.org/10.1063/1.4769996
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.