We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of ions at an energy of 39 keV root mean square emittances of 1–4 mm mrad and a brightness of were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.
Skip Nav Destination
Article navigation
February 2010
Research Article|
February 04 2010
Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type
Alexandra Silze;
Alexandra Silze
a)
1Institut für Angewandte Physik,
Technische Universität Dresden
, Helmholtzstr. 10, D-01062 Dresden, Germany
Search for other works by this author on:
Erik Ritter;
Erik Ritter
1Institut für Angewandte Physik,
Technische Universität Dresden
, Helmholtzstr. 10, D-01062 Dresden, Germany
Search for other works by this author on:
Günter Zschornack;
Günter Zschornack
1Institut für Angewandte Physik,
Technische Universität Dresden
, Helmholtzstr. 10, D-01062 Dresden, Germany
Search for other works by this author on:
Andreas Schwan;
Andreas Schwan
2
DREEBIT GmbH
, Zur Wetterwarte 50, D-01109 Dresden, Germany
Search for other works by this author on:
Falk Ullmann
Falk Ullmann
2
DREEBIT GmbH
, Zur Wetterwarte 50, D-01109 Dresden, Germany
Search for other works by this author on:
a)
Electronic mail: [email protected].
Rev. Sci. Instrum. 81, 023303 (2010)
Article history
Received:
August 04 2009
Accepted:
December 12 2009
Citation
Alexandra Silze, Erik Ritter, Günter Zschornack, Andreas Schwan, Falk Ullmann; Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type. Rev. Sci. Instrum. 1 February 2010; 81 (2): 023303. https://doi.org/10.1063/1.3284512
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Evaluating deuterated-xylene for use as a fusion neutron spectrometer
J. L. Ball, E. Panontin, et al.
Related Content
Status report of the Dresden EBIS/EBIT developments
Rev. Sci. Instrum. (February 2010)
Production of low-Z ions in the Dresden superconducting electron ion beam source for medical particle therapy
Rev. Sci. Instrum. (February 2012)
Compact electron beam ion sources/traps: Review and prospects (invited)
Rev. Sci. Instrum. (February 2008)
Molecule fragmentation at the Dresden EBIS-A
Rev. Sci. Instrum. (February 2008)
Short time ion pulse extraction from the Dresden electron beam ion trap
Rev. Sci. Instrum. (February 2010)